Specifications
para 43d.1
fig. 11.1
Page 14, paragraph 19: In last line, change "475”
In some equipment (para 1d(5)(d)), the tested
to 402.
voltage is connected through rf choke L7301 and
Paragraph 22: In line 5, add “R7918” after across voltage divider network consisting of
C7901.
variable resistor R7919 and resistors R7922 and
-
Paragraph 23, line 5. “R7901” is changed to
R7920.
read R7910.
Figure 10.1 is superseded by new figure 10.1.
Page 16, paragraph 27.1. The following sentence
is added after the second sentence:
Figure 10.1. Test in selector switch position 19. simplified
schematic
Page 29, paragraph 33d. Troulbleshooting Chart.
Make the following changes for symptom 2; insert
the material before the first probable trouble and
correction ("Diode CR7902, etc.”). In Probable
trouble column, insert: Knob on selector switch S7901 is set
180 degrees from proper position.
In Correction column, insert: Set S7901 to position 11. If
GREEN Indicator lights. remove the switch knob and install it
with the arrow pointing to position A. If GREEN indicator does
not Iight, replace the lamp.
diagram.
Page 20, paragraph 33d, Troubleshooting Chart,
Make the following changes for symptom 4; insert
the material before the first probable trouble and
correction (“Defective R7902, etc.“). In Probable
trouble column. insert: In equipment provided with poten-
tiometer R7902 (fig. 11.1. para Id(5)(d)). the potentiometer is out
of adjustment.
In Correction column, insert: Adjust potentiometer
R7902 (para 43d.1).
Page 21. paragraph 33d, Troubleshooting Chart.
Add the following material after symptom 13.
4