Specifications
ME-30B/U. The RED indicator
should be lighted.
(3) Increase the audio output of the TS-
382 F/U to 6.4 volts. The GREEN
indicator should be lighted.
65. Amplifier Tests, 5.65-Mc
(fig. 34)
Check the ability of the TS-1777/VRM-l
to test 5.65-mc amplifier circuits as di-
rected below.
a. Preparation.
(1) Insert the test probe tip in test jack
A, turn the selector switch to A,
and check to be sure that the
GREEN indicator lights.
(2) Connect the output of Hf Signal Gen-
erator 606A adjusted to 5.65 mc to
the test probe.
(3) Connect Rf Millivoltmeter 411A
across the 606A output.
b. Position 12 Test.
(1) Turn the selector switch to 12.
(2) Adjust the 606A for an output of
0.09 volt ac as indicated by the
411A. The RED indicator should be
lighted.
(3) Increase the rf output of the 606A
to 0.18 volt. The GREEN indicator
should be lighted.
c. Position 15 Test.
(1) Turn the selector switch to 15.
(2) Adjust the 606A for an output of
0.11 volt ac as indicated by the
411A. The RED indicator should be
lighted.
(3) Increase the rf output of the 606A
to 0.22 volt. The GREEN indicator
should be lighted.
d. Position 16 Test.
(1) Turn the selector switch to 16.
(2) Adjust the 606A for an output of
0.24 v 01 t ac as indicated by the
411A. The RED indicator should be
lighted.
(3) Increase the rf output of the 606A
to 0.48 volt. The GREEN indicator
should be lighted.
e. Position 17 Test.
(1) Turn the selector switch to 17.
(2) Adjust the 606A for an output of
0.36 volt ac as indicated by the
411A. The RED indicator should be
lighted
(3) Increase the rf output of the 606A
to 0.72 volt. The GREEN indicator
should be lighted.
66. Amplifier Tests, 11.5-Mc
(fig. 34)
Check the ability of the TS-1777/VRM-l
to test the 1.5-mc amplifier circuits as
directed below.
a. Preparation.
(1) Insert the test probe tip in test jack
A, turn the selector switch to A,
and check to be sure that the
GREEN indicator lights.
(2) Adjust Hf Signal Generator 6o6A
output frequency to 11.5 mc and
connect it to the test probe.
(3) Connect Rf Millivoltmeter 411A
across the 606A output.
b. Position 7 Test.
(1) Turn the selector switch to 7.
(2) Adjust the 606A for an output of
0.13 volt ac as indicated on the
411A. The RED indicator should be
lighted.
(3) Increase the rf output of the 606A
to 0.27 volt. The GREEN indicator
should be lighted.
c. Position 9 Test.
(1) Turn the selector switch to 9.
(2) Adjust the 606A for an output of
0.06 volt ac as indicated on the
411A. The RED indicator should be
lighted.
(3) Increase the rf output of the 606A
to 0.13 volt. The GREEN indicator
should be lighted.
d. Position 13 Test.
(1) Turn the selector switch to 13.
(2) Adjust the 606A for an output of
0.11 volt ac as indicated by the
411A. The RED indicator should be
lighted.
(3) Increase the rf output of the 606A
to 0.225 volt. The GREEN indicator
should be lighted.
e. Position 14 Test.
(1) Turn the selector switch to 14.
(2) Adjust the 606A for an output of
0.007-volt ac as indicated by the
67