1.8 Auto Bypass
The system can be armed and will automatically bypass faulted zones. Ask your installation company if you desire this feature.
1.9 Zone Bypass
There may be occasions when it is desirable or necessary to temporarily bypass one or more zones prior to arming the system. Bypass
commands only work when the control panel is disarmed. For instance, an open window may cause the DS7447 display to read "Not Ready"
followed by the zone number. The DS7443 or DS7445 may have one of its zone LEDs on steady.
Only one zone may be bypassed each time the command is used. If more than one zone requires bypassing, repeate the command for each
zone to be bypassed.
NOTE: See Section 1.7 Force Arming for another method of zone bypassing.
Page 20
Fire Trouble
A Fire Trouble display signifies a problem with the fire system, such as a break in the wiring that monitors smoke detectors.
A Fire Trouble will be indicated by a short beep from the keypad sounders every 10 seconds. The DS7447 will display “Fire Trouble” followed
by the zones in a trouble condition. The DS7443 will turn the
Fire light on steady and will light the corresponding zone LEDs. The DS7445 will
turn the
Fire and Trouble lights on steady and will light the corresponding zone LEDs.
Notify your installing company immediately if the Fire Trouble message is displayed.
The Fire Trouble beep can be silenced with any PIN followed by the [Off] key. After problems have been remedied, a PIN followed by [System
Reset] should be entered to clear the “Fire Trouble” display.
1.16 Remote Program Dial-out and Answer
Note: These features should be used by qualified installation personnel only.
Call for Remote Programming
This command can only be entered when the control is disarmed. Phone numbers 1 and 3 must be programmed, along with account code 1.
The panel will call phone number 3 and attempt to connect for downloading. While programming is underway the Status, Armed, and Power
LEDs will flash. If the panel is already using the phone line, it will sound the three beep error tone.
Answer for Remote Programming
The panel will automatically pick up the phone line to answer a remote programming call. While programming is underway the Status, Armed,
and Power LEDs will flash. If the panel is already using the phone line for a report communication, it will sound the three beep error tone. This
command can only be entered when the control is disarmed.
This chart will help you to call or answer the Remote Programmer.