User guide

DS7060 Reference Guide Copyright © 1996-97 Detection Systems, Inc. Page 37
SIA Format
SIA reporting allows the installer to select the type of event each report
will send to the central station. For example, if a burglary zone is used as
a 24 hour panic zone, it can now report as a PA (Panic Alarm) when using
the SIA Format.
The event type is programmed in the extended digit of the report (ad-
dresses 24-36). To activate a report using the SIA Format, place a “1” (or
any digit other than 0) in the first reporting digit. To select the type of event
for this report, place one of the following values as the second (extended)
digit.