User guide
DS7060 Reference Guide Copyright © 1996-97 Detection Systems, Inc. Page 3
1.0 SYSTEM OVERVIEW
The DS7060 Control/Communicator is a fully integrated hard-wire
security and residential fire alarm system. It can support up to 6
input zones and 15 individual users. Up to 4 keypads may be used to
provide user interface with the system, as well as programming ac-
cess for the installer.
2.0 SPECIFICATIONS
2.1 Enclosure Housing
The enclosure is manufactured from 22 Ga. (0.65 mm), cold-rolled
steel, and measures 9.25" Wide, by 10.25" High, by 3" Deep (23.5
cm Wide, by 26 cm High, by 7.6 cm Deep). The door has a knockout
for a standard DS lock (optional). The enclosure has a slot in the
back and also has an optional tamper switch mounting bracket with a
plunger switch.
2.2 Temperature
• Operating temperature: +32°F to +120°F (0°C to +49°C)
• Storage temperature: -20°F to +150°F (-28°C to +66°C)
2.3 Power
• Input Power: 16.5 VAC, 20 VA, 50 or 60 Hz
• Auxiliary Regulated Power: 12-12.5 VDC, 0.8 A
• Auxiliary Power Voltage Range: 10 to 13.8 VDC
• Optional Standby battery (P334): 12 V, 7.0 AH
• Control Panel Current Draw: 65 mA
• DS7443 Keypad Current Draw: 45 mA, Standby 45 mA, Alarm
• DS7445 Keypad Current Draw: 75 mA, Standby 75 mA, Alarm
• DS7447 Keypad Current Draw: 100 mA, Standby 100mA,
Alarm
2.4 Outputs
The total combined power output of the Programmable Outputs, Key-
pads and Accessories cannot exceed 800 mA.
• Programmable Output 1* Solid state, switch to ground
(500 mA max.).
• Programmable Output 2* Solid state, switch to ground
(500 mA max.).
• Programmable Output 3** Contacts switch to 12 V @ 750
mA.
* = The combined current draw of Programmable Output 1 and
Programmable Output 2 cannot exceed 750 mA.
** = The combined current draw of Programmable Output 3 and
the keypads cannot exceed 750 mA.
Refer to Section 7.8 for detailed Output operation.
2.5 Zones
• 6 zones
• Zone Response Time: All six zones can be programmed to re-
spond at either 300 ±100 ms or a programmable time (common to
all zones) that can be configured to be between 10 ms and 2.5
seconds. Zones are ignored for 15 seconds after power up, and for
two seconds after a system reset.
Refer to Sections 7.2 - 7.7 for detailed zone operation.
2.6 Keypads
• Total number of keypads: 4 Keypads
• Maximum wire length total in system: 1000 ft. (305 m)
• Wire type: 22 AWG (0.8 mm)
NOTE: Keypads may be up to 1000 ft. (305 m) from the panel when
#22 (0.8 mm) wire is used. Keypads may be “home-run” or
“daisy-chained” with a maximum of two keypads per wire
run.
2.7 Communicator
Will report to two phone numbers with full single, double, and backup
reporting. Communicated in 3/1, 3/1E, 3/1 with Parity, 3/1E with Par-
ity, 4/1, 4/2, High Speed 4/9, Pager, SIA (110 and 300 baud), Contact
ID, and Personal Dialing formats.
Refer to Sections 7.14 - 7.33 for communicator operation.
The ringer equivalence is 0.1 B.
2.8 Users
The system allows up to 15 individual users. Each user will have his
own PIN number (the 4 digit code entered at the keypads).
See Address 46 (Section 7.34) for programming the Master PIN Num-
ber. Refer to Users Guide (P/N 29955) for PIN programming.
2.9 Lightning Protection
MOVs and/or spark gaps provide protection from lightning surges
and static discharges.
2.10 Burglar/Fire Zone Inputs
• Number of Circuits: 6 Circuits on board
• End-of-Line Resistor: 2.21k ohms
NOTE: 4 wire type smoke detectors only.
2.11 Line Seizure Notice
This control panel incorporates a line seizure feature which will dis-
able internal telephone lines when the control panel is sending alarm
or supervision reports to the central station.