User guide
DS7060 Reference Guide Copyright © 1996-97 Detection Systems, Inc. Page 29
3. General Control Programming:
• Must be programmed for Swinger Shunts disabled, Closing Ringback disabled, 60 Hz, Auto Bypass disabled and Force Arming
disabled (Program Address 10).
4. Zone Programming:
• The Burglar alarm output signal, Address 04, (whether pulsed or steady) must be different from the Fire alarm signal.
5. Alarm Output Programming:
• Program Address 08 must be programmed as [X] [X] [8].
Note: Grade AA requires central station polls of the protected premise unit once every 5 minutes during armed periods and randomly
during disarmed periods. A central station poll once every 24 hours is acceptable for Grade A installations.
Grade B Installations using Digital Alarm Communicator Transmitter with local bell
Required Accessories:
• The control must be mounted in the Detection Systems’ model 7060CC enclosure with a cover actuated tamper switch installed.
• The Ademco Model AB-12 bell/housing (see Section 8.4).
1. Report Programming:
• Burglar Zone Reports must be programmed for those zones used.
• Low Battery Report (Program Address 32) must be programmed.
• AC Failure Report (Program Address 32) must be programmed.
• Open Report (Program Address 31) must be programmed.
• Close Report (Program Address 31) must be programmed.
• Automatic Test Reports (Program Address 36) must be programmed.
2. Timer Programming:
• Bell Cutoff Times (Program Address 23) must be programmed for not less than 15 minutes.
• Entry, Exit Delay Times (Program Address 23) must be programmed for not longer than 60 seconds.
3. General Control Programming:
• Must be programmed for Swinger Shunts disabled, Closing Ringback disabled, 60 Hz, Auto Bypass disabled and Force Arming
disabled (Program Address 10).
4. Zone Programming:
• The Burglar alarm output signal, Address 04 (whether pulsed or steady) must be different from the Fire alarm signal.
5. Alarm Output Programming:
• Program Address 08 must be programmed as [X] [X] [8].
Grade C Installations using Digital Alarm Communicator Transmitter only
Required Accessories:
• The control must be mounted in the Detection Systems’ model 7060CC enclosure with a cover actuated tamper switch installed.
1. Report Programming:
• Burglar Zone Reports must be programmed for those zones used.
• Low Battery Report (Program Address 32) must be programmed.
• AC Failure Report (Program Address 32) must be programmed.
• Open Report (Program Address 31) must be programmed.
• Close Report (Program Address 31) must be programmed.
• Automatic Test Report (Program Address 36) must be programmed.
2. Timer Programming:
• Entry, Exit Delay Times (Program Address 23) must be programmed for not longer than 60 seconds.
3. General Control Programming:
• Must be programmed for Swinger Shunts disabled, Closing Ringback disabled, 60 Hz, Auto Bypass disabled and Force Arming
disabled (Program Address 10).
4. Zone Programming:
• The Burglar alarm output signal, Address 04, (whether pulsed or steady) must be different from the Fire alarm signal.
5. Alarm Output Programming:
• Program Address 08 must be programmed as [X] [X] [8].