User guide

Page 28 Copyright © 1996-97 Detection Systems, Inc. DS7060 Reference Guide
2. Timer Programming:
Entry, Exit Delay Times (Program Address 23) must be programmed for not longer than 60 seconds.
3. General Control Programming:
Must be programmed for Swinger Shunts disabled, Closing Ringback disabled, and Force Arming disabled (Program Address
10).
4. Zone Programming:
The Burglar alarm output signal, Address 04, (whether pulsed or steady) must be different from the Fire alarm signal.
5. Alarm Output Programming:
Program Address 08 must be programmed as [X] [X] [8].
Grade A Installations using Digital Alarm Communicator Transmitter with local bell
Required Accessories:
The control must be mounted in the Detection Systems’ model 7060CC enclosure with a cover actuated tamper switch installed.
The Ademco Model AB-12 bell/housing (see Section 8.4).
1. Report Programming:
Burglar Zone Reports must be programmed for those zones used.
Low Battery Report (Program Address 32) must be programmed.
AC Failure Report (Program Address 32) must be programmed.
Open Report (Program Address 31) must be programmed.
Close Report (Program Address 31) must be programmed.
Automatic Test Reports (Program Address 36) must be programmed.
2. Timer Programming:
Bell Cutoff Times (Program Address 23) must be programmed for not less than 15 minutes.
Entry, Exit Delay Times (Program Address 23) must be programmed for not longer than 60 seconds.
3. General Control Programming:
Must be programmed for Swinger Shunts disabled, Closing Ringback disabled, 60 Hz, Auto Bypass disabled and Force Arming
disabled (Program Address 10).
4. Zone Programming:
The Burglar alarm output signal, Address 04, (whether pulsed or steady) must be different from the Fire alarm signal.
5. Alarm Output Programming:
Program Address 08 must be programmed as [X] [X] [8].
Central Station Burglary Alarm
The control must be installed in accordance with U. L. Standards UL611 and UL681 for all grades of service.
Grades AA and A Installations using the Applied Spectrum PAL200 and the DACT
Required Accessories:
The control must be mounted in the Detection Systems’ model 7060CC enclosure with a cover actuated tamper switch installed.
The Applied Spectrum PAL200.
The Applied Spectrum PAL200 must be installed within 3 feet of the control and the wiring from the Applied Spectrum PAL200 to the
control must be in conduit.
The Applied Spectrum PAL200 inputs should be connected to the alarm outputs (the active alarm sounder output may be used).
1. Report Programming:
Programming shall be enabled to allow all alarm signals to be transmitted via the DACT and PAL200.
Burglar Zone Reports are not required since the alarms are transmitted over the PAL200.
Low Battery Report (Program Address 32) must be programmed.
AC Failure Report (Program Address 32) must be programmed.
Open Report (Program Address 31) must be programmed.
Close Report (Program Address 31) must be programmed.
Automatic Test Reports (Program Addresses 36) be programmed.
2. Timer Programming:
Entry, Exit Delay Times (Program Address 23) must be programmed for not longer than 60 seconds.