User guide
Page 20 Copyright © 1996-97 Detection Systems, Inc. DS7060 Reference Guide
7.23 Address 29 - Zone Bypass Report
• Zone Bypass Reports are sent with the Closing Report. Address 20 digit 1 (left most digit) must be set for 2 or 3 for these reports. See
Section 7.14 - Report Control.
7.24 Address 30 - Zone Bypass Restoral Report
• Zone Bypass Restoral Reports are only sent with an Opening Report. Address 20 digit 1 (left most digit) must be set for 2 or 3 for
these reports. See Section 7.14 - Report Control.
7.25 Address 31 - Open/Close Duress Report
• Open: This report is sent when the system has been disarmed. In Contact ID, SIA or 4/9 formats, the user number for the person who
disarmed the system will be sent with this report. To send the user number along with an Open Report in other formats, program the
extended digit of the report as F ([*] [5]). The Open Report will only be sent if a Close Report was sent previously.
• Close: This report is sent when the system has been armed. In Contact ID, SIA or 4/9 formats, the user number for the person who
armed the system will be sent with this report. To send the user number along with a Close Report in other formats, program the ex-
tended digit of the report as F ([*] [5]).
• Duress: This report is sent when the system is disarmed using a duress code. The user number will not be sent along with this re-
port.
• Partial Close: This report is sent when the system is armed partially, or force armed.
• First Open After Alarm: This report is sent when the system is disarmed after an alarm has occurred. It will also be sent if the system
is already disarmed and a user number is entered to silence a 24-hour or fire zone.