User guide

DS7060 Reference Guide Copyright © 1996-97 Detection Systems, Inc. Page 13
Armed: This is an output programmed to activate when the system is armed. It will remain activated until the system is disarmed.
Ground Start: This is an output programmed to activate for 3 seconds when the phone line is seized. It is intended for use with
ground start phone systems that require a momentary short to ground to obtain a dial tone. Connect a separate 12 VDC, DPDT relay.
Connect both relay commons to ground, and connect the N/O of each contact to terminal positions 23 and 26 (one to terminal 23, one
to 26) of the DS7060. Connect one side of the relay coil to the selected Programmable Output and the other side of the coil to 12 volts
(Terminal 5) (if PO1 or PO2 is used), or to any Panel Common terminal if PO3 is used. Not intended for U. L. Listed systems. Not for
use with phone line monitors.
Ready to Arm (System Status): This is an output programmed to follow the “Status” light of the keypad. It will activate when the sys-
tem is ready to arm with no zones violated.
Follow Burg Alarm: This is an output programmed to activate when a zone is in an alarm condition. It will remain activated until the
system is disarmed or the bell cutoff time expires. This output is intended to activate bells and sirens. This will not activate from Silent
or Invisible zones.
Follow Fire Alarm: This is an output programmed to activate when a zone is in an fire alarm condition. It will remain activated until
the system is disarmed or the bell cutoff time expires. This output is intended to activate bells and sirens. This will not activate from Si-
lent or Invisible zones.
Follow Burg and Fire Alarm: This programs an output to activate when any zone goes into alarm condition.
Follow Keypad Sounder: This is an output programmed to follow the keypad sounder. It activates during the entry pre-alert . It does
not follow momentary keypad beeps such as keystrokes.
Duress: This output activates when the duress code is used to disarm the system. Note: If the Duress code is used to activate a Pro-
grammable Output, entering any valid PIN + [OFF} will deactivate the Programmable Output.
Trouble: This output activates when a trouble condition is present.
7.9 Address 09 - User Control
Duress Code: If this option is selected and Code 14 is used to disarm the system, a duress report will be sent as the system is other-
wise disarmed normally. User Code 14 will not arm the system, or report duress, if the system is not armed.
Guest Code: If this option is selected, Code 15 is a guest code. It can be enabled by pressing [PIN] [#] [8] [4]. It will remain active un-
til the panel is disarmed with any other valid code.
Arming Warning: If this option is selected, the alarm output will turn on for 2 seconds when the panel is armed.
Keypad Audible During Exit Delay: Selection of this option will cause the keypad sounders to beep during the exit delay time. A one
second beep will sound at 5 second intervals, changing to a 3-beep tone at 10 and 5 seconds prior to the end of the delay.
Keyswitch Arming Warning: Selecting this option will activate any output programmed as Intrusion, Follow Burg Alarm, or Follow
Burg Alarm and Fire Alarm. The output will beep once (200 ms ON) when a keyswitch toggle zone arms the system. A double beep