Page 12 Copyright © 1996-97 Detection Systems, Inc. DS7060 Reference Guide
7.6 Address 06 - Programmed Zone Response Time
7.7 Address 07 - Zone Restoral Options
Restore when Sounders Silence: If programmed, a zone sends a restoral report and is ready to activate again only after the burglary
bell cutoff time expires or the bells are silenced. The zone can alarm multiple times per armed period.
Restore with Zone: If programmed, a zone sends a restoral report and is ready to activate again as soon as it physically restores.
The zone can alarm multiple times per armed period.
Restore when Disarmed (or Reset): If the zone returns to normal before the bell timer elapses, the alarm display will continue and
no restoral will be reported. When the bell timer then elapses, whether or not the zone has restored, the bell will shut down (if select-
ed) but the alarm display will continue and no restoral will be reported. When the system is disarmed (or reset) the bell will silence, the
displays will clear and restoral will be reported along with the open/reset event (if programmed). If the zone is a 24 hour zone and has
not restored to normal, will not report zone restoral until the zone restores. Unrestored 24 hour zones will show as “not ready” and will
prevent the system from arming. In this case, the system will reinitiate the sounders and displays for those zones, but will not send any
fire alarm transmission to the central station for those zones, unless a previous restoral has been sent. Fire zones always restore
when the system is reset, regardless of this selection.
7.8 Address 08 - Outputs
Intrusion: This is an output programmed to latch with any Burg zone alarm, including invisible and silent zones. It will remain latched
until the system is disarmed regardless of the restore setting for the zone.
On During Entry Pre-Alert: This is an output programmed to activate when a perimeter delayed type zone is violated while the sys-
tem is armed. It will remain activated until the system is disarmed, or until the entry delay time has expired.
System Reset: This is an output programmed to activate only for 10 seconds after a PIN + [System Reset] is entered at a keypad or if
a fire zone with verification activates. Output 1 turns on for 10 seconds, outputs 2 and 3 turn off for 10 seconds. Outputs 2 and 3 are
intended to be used to power 4-wire smoke detectors or any other device that requires a power interruption to reset an alarm condition.
Sets the time value used in Address 05.