Specifications

DS7400Xi Ver. 3+ Reference Guide Copyright © 1995-96 Detection Systems, Inc. Page 55
12.33 Output Function Programming: Program Addresses (1472-1516)
Example:
To program the Output Function 1 to follow a Zone Burg
Alarm.
Data Digit 1 = [6], Data Digit 2 = [1],
Enter the Programmer’s Mode: [9] [8] [7] [6] [#] [0]
Enter the Program Address: [1] [4] [7] [2]
Enter Data Digit 1: [6]
Enter Data Digit 2: [1]
Enter the pound key: [#]
Program the next Address, Program a different Address, or
Exit the Programmer’s Mode.
Output programming allows you to have the Outputs follow status
events by partition or system-wide, or follow zone outputs in an
Input/Output Cross Matrix. See the Programming Addresses Work-
sheet (P/N 29802) for a description of each address. See System
Overview (section 6.1.7) for further details.
*0 - *5 are Hex values. They will display as A - F at
the keypads.
Zone Trouble
Supervisory
Select Option
DDDD
Select Option
1
Communication Failure
System Fault (any)
Keypad Supervision Fault
Multiplex Bus Fault
Radio Receiver Fault
3
4
5
6
7
8
9
Duress PIN
*1
Data Digit
12
*0
*2
*2
Low Battery
AC Power Failure
2 Aux Power Fault
Fire Trouble
*0 - *2 are Hex values. They will display as A - C at the keypads.
** = This is only for DS7465 Outputs. DS7488 Outputs will not latch when this is selected.
Access output (10 sec. pulse)
Latch ON after Zone Alarm
7
8
9
Data Digit
12
ON during Entry Pre-Alert
ON when system is armed
Zone alarm
Zone Alarm delayed by 20 sec.
Keypad Sounder output
1
3
6
Panic/Duress output** *1
Follows
Disabled
1 2 3
Burglar Alarm
Fire Alarm
Data Digit
0
0
DDSelect Option
Follow a single zone
Follow System Status Event
Follow two zones-When EITHER zone changes state
Follow two zones-When BOTH zones change state
*2
*3
*4
*5
Data Digit 1 Options 1-*1 are used to program an Output
Function to follow status events for individual partitions.
Data Digit 1 Option *2 is used to program an Output
Function to follow status events system-wide.
Data Digit 1 Options *3-*5 are used to program an Output
Function to follow a zone or two zones in an Input/Output
Cross Matrix.
Enter the
Zone Number
of Second
Zone to
Follow
(01 - 99)
Enter the
Zone Number
of First Zone
to Follow
(01 - 99)
2
Data Digit
1
Data Digit
12
0 2345
When panel is not Armed
When panel is Armed
When Zone is opened
When zone is shorted
Activate:
Data Digit
12
Data Digit
12
1
Disabled
6
Enter Data Digit as a:
8
7 9 *0 *1 *2
Latch when activated**