Specifications
DS7400Xi Ver. 3+ Reference Guide Copyright © 1995-96 Detection Systems, Inc. Page 53
12.31 Programmers and Master Code Programming: Programming Addresses (0532-0534)
Example:
To program the Programmer’s Code to be 3 4 4 3.
Data Digit 1 = [3], Data Digit 2 = [4],
Data Digit 3 = [4], Data Digit 4 = [3].
Enter the Programmer’s Mode: [9] [8] [7] [6] [#] [0]
Enter the Program Address: [0] [5] [3] [2]
Enter Data Digit 1: [3]
Enter Data Digit 2: [4]
Enter Data Digit 3: [4]
Enter Data Digit 4: [3]
Enter the pound key: [#]
Program the next Address, Program a different
Address, or Exit the Programmer’s Mode.
Programmer’s Code
Enter as 4 digits.
It can not be the same
as any PIN number.
123 4
The Default for the Programmer’s Code = 9876
Program Address 0532
Data Digit
Programmer’s Code programming defines
what the Programmer’s Code will be. This
code is used to enter the programming
mode from the keypads.
Master Code PIN Number
(Default for this User 001 is 1234)
123 4
Program Address 0534
Data Digit
Master Code programming defines what the Master Code will be. This code is the highest authority level for a PIN.
If the Master Code is lost, this address may be used to program a new one.
Otherwise, the Master Code Programming Mode should be used to create PINs
that have a Master Code authority level.
Master Code for User Number 001 has its authority
fixed at level 0. It will always have access to all par-
titions.
Note:
User Numbers 002 through 090 must be pro-
grammed from the Master Code Programming
Mode.
12.32 Octal Relay Module Output Programming: Program Addresses (1456-1471)
Example:
To program the Octal Relay Module’s Output # 9
to follow Output Function 1.
Data Digit 1 = [*] [3], Data Digit 2 = [1],
Enter the Programmer’s Mode: [9] [8] [7] [6] [#] [0]
Enter the Program Address: [1] [4] [6] [4]
Enter Data Digit 1: [*] [3]
Enter Data Digit 2: [1]
Enter the pound key: [#]
Program the next Address, Program a different
Address, or Exit the Programmer’s Mode.
DD
0Latch ON after Zone Alarm**
ON during Entry Pre-Alert
ON for 10 sec. after pressing [System Reset]
ON when System is Armed
Ground Start
System Status (Ready to Arm)
Zone Alarm
Zone Alarm delayed by 20 seconds
Keypad Sounder Output
Access Output (10 sec. pulse)
1
2
3
4
5
6
7
8
9
12
Data Digit
Select Option
Panic/Duress Output*** *1
** = This includes invisible zones. See glossary for further details.
*** = See section 7.4 for description of this option.
Follows
Disabled
0 1 2
Burglar Alarm
Fire Alarm
Data Digit
These two charts are for programming
the Octal Relay Module to follow events
by partition.
Octal Relay partition assignments are
programmed in addresses 3725-2732.
See Section 12.32.1
3
Follow System Wide Events
Follow Output Functions
*2
*3
See next page for programming options *2 and *3
DS7488-1
Addresses
1
2
3
4
5
6
7
8
1456
1457
1458
1459
1460
1461
1462
1463
Octal
Relay #
DS7488-2
Addresses
9
10
11
12
13
14
15
16
1464
1465
1466
1467
1468
1469
1470
1471
Octal
Relay #
The Octal Relay Module is the DS7488. See section 1.14 and 6.1.6 for further details.
Continued on next page