12.8 Partition Control Programming: Program Address (0165)
Example:
To program the Partition Control as: the System will use 3 Partitions,
and Partition 1 is common to Partitions 2 and 3.
Data Digit 1 = [2], Data Digit 2 = [1].
Enter the Programmer’s Mode: [9] [8] [7] [6] [#] [0]
Enter the Program Address: [0] [1] [6] [5]
Enter Data Digit 1: [2]
Enter Data Digit 2: [1]
Enter the pound key: [#]
Program the next Address, Program a different Address, or Exit the
Programmer’s Mode.
1
2
3
4
5
6
0No Common Area
Partition 1 Common to Partition 2 and 3
Select Option
DD
Data Digit
12
1
2
3
4
5
6
7
0Use 1 Partition
Use 2 Partitions
Use 3 Partitions
Use 4 Partitions
Use 5 Partitions
Use 6 Partitions
Use 7 Partitions
Use 8 Partitions
Select Option DD
Partition 1 Common to Partition 2 - 4
Partition 1 Common to Partition 2 - 5
Partition 1 Common to Partition 2 - 6
Partition 1 Common to Partition 2 - 7
Partition 1 Common to Partition 2 - 8
Partition Control programming defines the number of partitions in use
and the common area (common area can only be partition 1).
See Glossary (section 7.5) for further details.
12.9 Quick Arm Control Programming: Program Address (0169)
Example:
To program so that Partitions 1 and 2 can be quick armed, while Parti-
tions 3 through 8 can not be quick armed.
Data Digit 1 = [3], Data Digit 2 = [0].
Enter the Programmer’s Mode: [9] [8] [7] [6] [#] [0]
Enter the Program Address: [0] [1] [6] [9]
Enter Data Digit 1: [3]
Enter Data Digit 2: [0]
Enter the pound key: [#]
Program the next Address, Program a different Address, or Exit the
Programmer’s Mode.
Data Digit
12
0
123456789*0 *1 *2 *3 *4 *5
Partition 1 Quick Arm Enabled
Select Options
Enter the Data Digit as a:
Partition 4 Quick Arm Enabled
Partition 3 Quick Arm Enabled
Partition 2 Quick Arm Enabled
0
1 2 3 4 5 6 7 8 9 *0 *1 *2 *3 *4 *5
Partition 5 Quick Arm Enabled
Select Options
Enter the Data Digit as a:
Partition 8 Quick Arm Enabled
Partition 7 Quick Arm Enabled
Partition 6 Quick Arm Enabled
Quick Arm Control programming defines which partitions can be
quick armed (armed without requiring a PIN to be entered).