Specifications
DS7400Xi Ver. 3+ Reference Guide Copyright © 1995-96 Detection Systems, Inc. Page 37
12.5 Zone Bypass Programming: Program Addresses (0016-0017)
Example:
To program zone functions 1 - 7 so they can not be
bypassed and zone function 8 so it can be by-
passed.
Data Digit 1 = [*] [5], Data Digit 2 = [7].
Enter the Programmer’s Mode: [9] [8] [7] [6] [#] [0]
Enter the Program Address: [0] [0] [1] [6]
Enter Data Digit 1: [*] [5]
Enter Data Digit 2: [7]
Enter the pound key: [#]
Program the next Address, Program a different
Address, or Exit the Programmer’s Mode.
12
Data Digit
PA 0016
1 2 3 4 5 6 7 8 9 *0 *1 *2 *3
*4
*5
Zone Function 1 Can Be Bypassed
Select Options
Enter the Data Digit as a:
*0 - *5 are Hex values. They will display as A - F at the keypads.
Zone Function 4 Can Be Bypassed
Zone Function 3 Can Be Bypassed
Zone Function 2 Can Be Bypassed
0
1 2 3 4 5 6 70 9 *0 *1 *2 *3 *4 *5
Zone Function 5 Can Be Bypassed
Select Options
Enter the Data Digit as a:
*0 - *5 are Hex values. They will display as A - F at the keypads.
Zone Function 8 Can Be Bypassed
Zone Function 7 Can Be Bypassed
Zone Function 6 Can Be Bypassed
8
Zone Bypass programming determines which zone functions can be by-
passed. Zone functions that can not be bypassed can not be force armed
either. Fire zones can never be manually bypassed, but can be force armed.
The Default of [0] or [8] means those zones can be bypassed.
*0 - *5 are Hex values. They will display as A - F at the keypads.
12
Data Digit
PA 0017
1 2 3 4 5 6 7 8 9 *0 *1 *2 *3 *4 *5
Zone Function 9 Can Be Bypassed
Select Options
Enter the Data Digit as a:
*0 - *5 are Hex values. They will display as A - F at the keypads.
Zone Function 12 Can Be Bypassed
Zone Function 11 Can Be Bypassed
Zone Function 10 Can Be Bypassed
0
1 2 3 4 5 6 7 8 9 *0 *1 *2 *3 *4 *5
Zone Function 13 Can Be Bypassed
Select Options
Enter the Data Digit as a:
Zone Function 15 Can Be Bypassed
Zone Function 14 Can Be Bypassed
0