Specifications
DS7400Xi Ver. 3+ Reference Guide Copyright © 1995-96 Detection Systems, Inc. Page 36
12.3 Zone Programming: Program Addresses (0018-0145)
Example:
To program a Zone (Zone 1) as: a Single Zone Input (PIR) and follows
Zone Function 1.
Data Digit 1 = [0], Data Digit 2 = [1].
Enter the Programmer’s Mode: [9] [8] [7] [6] [#] [0]
Enter the Program Address: [0] [0] [1] [8]
Enter Data Digit 1: [0]
Enter Data Digit 2: [1]
Enter the pound key: [#]
Program the next Address, Program a different Address, or Exit the
Programmer’s Mode.
In Zone Programming, each zone is defined according to:
• Input (single or multiple zone input, or a DS7465)
• Zone Function or Output function (1-15).
The DS7465’s relay is the only device that will follow the output functions;
its input loop will follow a zone function. All single and multiple zone inputs
will follow a zone function.
See section 6.2 and 7.3 for further details.
To program Output Functions, see section 12.33.
Data Digit
12
0Disabled
Follow Zone (or Output) Function 1
Follow Zone (or Output) Function 2
Follow Zone (or Output) Function 3
Follow Zone (or Output) Function 4
Follow Zone (or Output) Function 5
Follow Zone (or Output) Function 6
Follow Zone (or Output) Function 7
Follow Zone (or Output) Function 8
1
2
3
4
5
6
7
8
1
2
3
4
5
6
7
8
9-128
0018
0019
0020
0021
0022
0023
0024
0025
0026-0145
01
02
03
04
05
06
07
08
00
Zone Number Address Default
Select Option DD
Follow Zone (or Output) Function 9
Follow Zone (or Output) Function 10
Follow Zone (or Output) Function 11
Follow Zone (or Output) Function 12
Follow Zone (or Output) Function 13
Follow Zone (or Output) Function 14
Follow Zone (or Output) Function 15
9
*0
*1
*2
*3
*4
*5
*0 - *5 are Hex values.
They will display as A - F at the keypads.
Single Zone Input
(zones 1-8 on the control, multiplex contacts,
sensors, or a DS7457)
Multiple Zone Input
(any zone that is on a DS7432, DS7433, or DS7460)
DS7465 Connections
(the input zone or the output relay on a DS7465)
Hint: Address = Zone Number + 17
Select Option DD
0
2
1
12.4 Zone Partition Assignment: Program Addresses (1248-1311)
In Zone Partition Assignment, each zone is assigned to a parti-
tion. By default, all zones are assigned to partition 1.
The partition assignment for odd numbered zones is programmed
in the first data digit of these addresses. The partition assign-
ment for even numbered zones is programmed in the second
data digit of these addresses.
For example, to assign zone 1 to partition 1 and zone 2 to parti-
tion 2, program address 1248 as 01.
1
2
3
4
5
6
7
Data Digit
12
0Belongs to Partition 1
Belongs to Partition 2
Belongs to Partition 3
Belongs to Partition 4
Belongs to Partition 5
Belongs to Partition 6
Belongs to Partition 7
Belongs to Partition 8
Select Option DD
1
2
3
4
5
6
7
0Belongs to Partition 1
Belongs to Partition 2
Belongs to Partition 3
Belongs to Partition 4
Belongs to Partition 5
Belongs to Partition 6
Belongs to Partition 7
Belongs to Partition 8
Select Option DD
Partition Assignment Address
For Zones 1 and 2 1248
For Zones 3 and 4 1249
For Zones 5 and 6 1250
For Zones 7 and 8 1251
Zones 9 through 128
1252-1311