12.0 Programming
12.1 General Control Programmong: Program Address (0000)
Example:
To program the system-wide General Operating parameters as: allow-
ing Normal and Custom Arming, Operating at 60 Hz., and to Restore
when a Zone Restores.
Data Digit 1 = [2], Data Digit 2 = [1].
Enter the Programmer’s Mode: [9] [8] [7] [6] [#] [0]
Enter the Program Address: [0] [0] [0] [0]
Enter Data Digit 1: [2]
Enter Data Digit 2: [1]
Enter the pound key: [#]
Program the next Address, Program a different Address, or Exit the
Programmer’s Mode.
General Control programming defines the
system-wide general operating parameters.
See Glossary (section 7.1) for further details.
4
3
0Select Options 1 2 3 4 5 6 7
Allow Normal and Custom Arming**
Allow Perimeter Instant Arming**
Allow Perimeter Arming**
Allow Maximum Security Arming**
Closing Ring-Back
Data Digit
12
012
Restore zone when Sounders Silence
Restore zone when Zone Restores
Restore zone when System is Disarmed
Allow Swinger Shunts
Siren on Comm. Fail for Silent Zone
8 9 *0 *1 *2 *3 *4 *5
Enter the Data Digit as a:
Select Options
50 Hz. operation
60 Hz. operation
= For installations in North America, select 60 Hz. operation.
*0 - *5 are Hex values. They will display as A - F at the keypads.
5
Enter DD as a:
** = • Normal Arming = PIN + [On]: If programmed, Normal Arming arms the entire system while allowing entry
delays for entry/exit zones.
• Perimeter Instant Arming = [PIN] + [No Entry] [Perimeter Only]: If programmed, Perimeter Instant Arming arms only the
perimeter of the system and does not allow entry delays for entry/exit zones.
• Perimeter Arming = [PIN] + [Perimeter Only]: If programmed, Perimeter Arming arms only the perimeter of the system
while allowing entry delays for entry/exit zones.
• Custom Arming = [PIN] + [#] [4]: If programmed, Custom Arming allows custom arming of the system and bypasses the
zone functions specified in data address 0183.
• Maximum Security Arming = [PIN] + [No Entry] [On]: If programmed, Maximum Security Arming arms the entire system
and does not allow entry delays for entry/exit zones.