8.5 Changing the Time
This chart explains the procedure for changing the time at the keypad.
[Master Code] + [#] [0]
# 1. Enter the Master Code
Programming Mode.
"6 Change Time"*
(display will scroll to this)
Steps to Change
the Time
If Accepted, the Display Reads
“Enter Day"
(1...7)
"Enter Time."
(0100...1259)
"Enter AM/PM.”
(4/6) End with #
“Day - Time”
A long beep signifies acceptance.
# 2. Enter a 6.
# 3. Enter the day.
# 4. Enter the Time.
(Hour and minute)
# 5. Enter AM or PM.
[6]
[1]
through
[7]
Sunday Saturday
[0] [1] [0] [0]
through
[1] [2] [5] [9]
[4] [#] or [6] [#]
(4=AM, 6=PM)
Command
Sequence
* = This will only display when in Single Partition Mode.
The control panel will exit you from the master code programming mode after about 15 seconds without a keystroke.
It is recommended that this procedure be performed at a DS7447 keypad. No visual cues will be given from a DS7445 keypad.
Note: Entering the command sequence [Master Code] [#] [0] [6] [#] will cause the DS7447 keypad to read back the time.
8.6 Delayed Arming
This section explains how to cause the system to arm after a specified number of hours.
Delayed arming is simply causing the system to arm after a specified number of hours.
To program the system for delayed arming, perform the following steps:
NotesDelayed Automatic Arming
Enter a PIN
Enter [9] [9]
to enter the Delayed Arming programming
Enter the number of hours from now
that you would like the system to arm.
For example: If if is 3:30 now, and you
would like the system to arm at 9:30,
enter 06.
The keypad will display the following:
Arm in nn Hours
# to accept
Additional Notes:
Delayed arming can be used even if there are no automatic arming times programmed.
If delayed arming is used in Master Keypad mode, it will affect all partitions you have access to. If delayed arming is used in single partition
mode, or from a single partition keypad, it will affect only the partition you are working in.
Delayed arming will override automatic arming.
Delayed arming will also provide a 15 minute pre-arm period like the one provided with automatic arming.