Specifications
DS7400Xi Ver. 3+ Reference Guide Copyright © 1995-96 Detection Systems, Inc. Page 22
8.2 Arming/Disarming Commands
For commands to Arm, Disarm, Bypass or set chime mode, see the front cover of this Reference Guide or consult the DS7400Xi Ver. 3+
Users Guide.
8.3 Changing the Date
This chart explains the procedure for changing the date at the keypad.
# 4. Enter the Day.
# 3. Enter the Month.
# 1. Enter the Master Code
Programming Mode.
"2 Change Date"
(display will scroll to this)
[Master Code] + [#] [0]
Steps to Change
the Date
Command
Sequence
If Accepted, the Display Reads
# 2. Enter a 2.
# 5. Enter the Year.
“Enter Month"
(01...12)
"Enter Day."
(01...31)
"Enter Year."
(XX) End with #
“Month, Day, Year”
A long beep signifies acceptance.
[2]
[0] [1]
through
[1] [2]
January December
[0] [1]
through
[3] [1]
The last two digits of the year,
followed by the [#] key.
It is recommended that this procedure be performed at a DS7447 keypad. No visual cues will be given from a DS7445 keypad.
Note: Entering the command sequence [Master Code] [#] [0] [2] [#] will cause the DS7447 keypad to read back the date.
The control panel will exit you from the master code programming mode after about 15 seconds without a keystroke.
8.4 Changing the Tempoary PIN Expiration Date
This chart explains the procedure for changing the expiration date (for temporary PINs) at the keypad.
If Accepted, the Display Reads
[Master Code] + [#] [0]
# 1. Enter the Master Code
Programming Mode.
"3 Change Date of Code Expiration"*
(display will scroll to this)
“Enter Month"
(01...12)
# 2. Enter a 3.
"Enter Day."
(01...31)
# 3. Enter the expiration
Month.
# 4. Enter the expiration Day.
The temporary PIN will
expire at Midnight on the
day selected.
"Enter Year."
(XX) End with #
“Month, Day, Year”
A long beep signifies acceptance.
# 5. Enter the expiration Year.
[3]
[0] [1]
through
[1] [2]
January December
[0] [1]
through
[3] [1]
The last two digits of the year,
followed by the [#] key.
Steps to Change the Exp.
Date for Temp. PINs
Command
Sequence
* = This will only display when in Single Partition Mode.
The control panel will exit you from the master code programming mode after about 15 seconds without a keystroke.
It is recommended that this procedure be performed at a DS7447 keypad. No visual cues will be given from a DS7445 keypad.
Note:Entering the command sequence [Master Code] [#] [0] [3] [#] will cause the DS7447 keypad to read back the
temporary code expiration date.