User's Manual

5
o Depress Center Button for 10 seconds. All lights will flash (Blue, Yellow, Red) and
buzzer will beep one time.
o Cycle the power by simultaneously holding the open and close buttons for 10 seconds.
Active Mode:
o Device checks for water every 15 seconds at the same time as the LED blink
o Any connected valves will blink their status every 15 seconds
Alarm Mode:
o Device blinks red and beeps once every 3 seconds
Cycle will continue until S1 is pressed
o Details of the alarm are displayed, emailed, texted and phone calls are placed to
appropriate personnel.
Silence:
o Press S1 to silence the alarm
o Details of the silence are displayed, emailed, and texted to appropriate personnel.
Reset:
o For the lockout time that is designated in the User Interface, the sensor will be in a
reset mode where it will not detect water.
o Press and hold S1 for 10 seconds to exit reset mode, or wait for the lockout time to
expire
Test Mode:
o Press and Hold Center button for 20 seconds
o All messages during this time will be recorded as “Test” messages
o Test mode will automatically end after 120 seconds
Controlling Valves
o Open All Connected Valves: Press Left Button
In Process: LED Solid Yellow
On Success: LED Blue
Failure: Rapid RED LED
o Close All Connected Valves: Press Right Button
In Process: LED Solid Yellow
On Success: LED Blue
Failure: Rapid RED LED
o Control via the User Interface
Troubleshooting
o Failed Setup
Retry registration
Check that nearby Hubs and Smart Base Station are properly configured
Adjust the location of the Sensor
o Battery Warning/Alarm
Replace the batteries in the Sensor
o External DC Alarm
Check power connections at the device and at the wall
Check the wall outlet to ensure it is active
o Not Communicating
Retry registration
Check that nearby Hubs and Smart Base Station are properly configured
Adjust the location of the Sensor
o Valve(s) Failed