Flame, Gas, and Systems Product Catalog 2011-2012 Flame, Gas, and Systems Product Catalog August 1, 2011 Detector Electronics Corporation 6901 West 110th Street Minneapolis, MN 55438 USA ph: 952.941.5665 or 800.765.3473 fax: 952.829.8750 www.det-tronics.com det-tronics@det-tronics.com 52-1002-8.1 52-1002-8.
Product Catalog August 1, 2011 © 2011 Detector Electronics Corporation. All rights reserved. DET-TRONICS and DET-TRONICS logo, Protect•IR, Oi, xWatch, Infiniti, FlexVu, Pointwatch Eclipse, and Eagle Quantum Premier are registered trademarks or trademarks of Detector Electronics Corporation in the United States, other countries or both. Other company, product, or service names may be trademarks or service marks of others.
Table of contents FLAME X3301 Protect•IR® Multispectrum Infrared Flame Detector. . . . . . . . . . . . . . . . . . . Flame A.1 X3301 Model Matrix. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . X3301 Protect•IR Multispectrum Infrared Flame Detector (FM/CSA/ATEX/CE/IECEx). . . . . . . . . . . . . . . . . .
Table of contents FLAME CONTINUED... X-Series Flame Detector Accessories. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Flame E.1 X-Series Sensor Modules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Flame E.1 X-Series Flame Detector EMI Output Boards. . . . . . . . . . . . . . .
Table of contents FLAME CONTINUED... Output Devices for R7XXX Controllers. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Flame K.7 R1425 Rack Mount Detonator Module for the R7404 Controller. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Flame K.7 R6006 Rack Mount Relay Output Module. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Multispectrum infrared X3301 Protect•IR ® Multispectrum Infrared Flame Detector X3301 Protect•IR Multispectrum Infrared Flame Detector (Spec Sheet: 90-1143, 90-1144, 90-1190) establishes the benchmark in multiple-fuel fire detection performance and false alarm rejection. The detector utilizes advanced signal processing algorithms supported by an embedded 32-bit microprocessor to provide continuous protection in the presence of false alarm sources and environments with infrared radiation present.
Multispectrum infrared X3301 Model Matrix MODEL DESCRIPTION X3301 Multispectrum IR Flame Detector TYPE MATERIAL A Aluminum S Stainless Steel (316) TYPE THREAD TYPE 3M 3 Port, Metric M25 3N 3 Port, 3/4” NPT 4M 4 Port, Metric M25 4N 4 Port, 3/4” NPT TYPE OUTPUTS 11 Relay 13 Relay and 4-20 mA 14 Eagle Quantum Premier (EQP) 15 Relay and Pulse 16 Addressable Module Only (third-party type) 21 Relay - Automotive 22 EQP - Automotive 23 HART, Relay, and 4-20 mA 33 Relay and 4-20 mA
Multispectrum infrared X3301 Protect•IR Multispectrum Infrared Flame Detector (FM/CSA/ATEX/CE/IECEx) Model Part Number* Material Threads Output Ex d e X3301A4N11W1 X3301A4M11W1 X3301S4N11W1 X3301S4M11W1 008100-XXX 008101-XXX 008102-XXX 008103-XXX AL AL 316 SS 316 SS 3/4 NPT M25 3/4 NPT M25 Relay Relay Relay Relay X X X X X3301A4N11W2 X3301A4M11W2 X3301S4N11W2 X3301S4M11W2 008104-XXX 008105-XXX 008106-XXX 008107-XXX AL AL 316 SS 316 SS 3/4 NPT M25 3/4 NPT M25 Relay Relay Relay Relay X3301A4N
Multispectrum infrared X3301 Protect•IR Multispectrum Infrared Flame Detector – EQP (FM/CSA/ATEX/CE/IECEx) Model Part Number Material Threads Output Ex d e X3301A4N14W1 X3301A4M14W1 X3301S4N14W1 X3301S4M14W1 008124-001 008125-001 008126-001 008127-001 AL AL 316 SS 316 SS 3/4 NPT M25 3/4 NPT M25 EQP EQP EQP EQP X X X X X3301A4N14W2 X3301A4M14W2 X3301S4N14W2 X3301S4M14W2 008128-001 008129-001 008130-001 008131-001 AL AL 316 SS 316 SS 3/4 NPT M25 3/4 NPT M25 EQP EQP EQP EQP X3301A4N14W1 X3301A
Multispectrum infrared X3301 Protect•IR Multispectrum Infrared Flame Detector – Brazil Model Part Number* Material Threads Output X3301A4N11B2 X3301S4N11B2 X3301A4N13B2 X3301S4N13B2 008200-XXX 008201-XXX 008202-XXX 008203-XXX AL 316 SS AL 316 SS 3/4 NPT 3/4 NPT 3/4 NPT 3/4 NPT Relay Relay Relay/4-20 mA Relay/4-20 mA X3301A4N14B2 X3301S4N14B2 X3301A4N23B2 X3301S4N23B2 008204-001 008205-001 008206-XXX 008207-XXX AL 316 SS AL 316 SS 3/4 NPT 3/4 NPT 3/4 NPT 3/4 NPT EQP EQP Rly/4-20/HART Rly/4-20/H
Multispectrum infrared X3301 Protect•IR Multispectrum Infrared Flame Detector – Ukraine Model Part Number* Material Threads Output Ex d e X3301A4M11U1 X3301S4M11U1 X3301A4M11U2 X3301S4M11U2 008152-XXX 008153-XXX 008154-XXX 008155-XXX AL 316 SS AL 316 SS M25 M25 M25 M25 Relay Relay Relay Relay X X X3301A4M13U1 X3301S4M13U1 X3301A4M13U2 X3301S4M13U2 008156-XXX 008157-XXX 008158-XXX 008159-XXX AL 316 SS AL 316 SS M25 M25 M25 M25 Relay/4-20 mA Relay/4-20 mA Relay/4-20 mA Relay/4-20 mA X X X X T
Multispectrum infrared X3302 Protect•IR® Multispectrum Infrared Flame Detector X3302 Multispectrum Infrared Flame Detector (Spec Sheet: 90-1185) provides a solid cone of vision for hydrogen fire detection coupled with superior false alarm rejection. The detector utilizes advanced signal processing algorithms supported by an embedded 32-bit microprocessor to provide continuous protection in the presence of false alarm sources and environments with infrared radiation present.
Multispectrum infrared X3302 Model Matrix MODEL DESCRIPTION X3302 Multispectrum IR Flame Detector TYPE MATERIAL A Aluminum S Stainless Steel (316) TYPE THREAD TYPE 3M 3 Port, Metric M25 3N 3 Port, 3/4" NPT 4M 4 Port, Metric M25 4N 4 Port, 3/4" NPT TYPE OUTPUTS 13 Relay and 4-20 mA 14 Eagle Quantum Premier (EQP) 15 Relay and Pulse 16 Addressable Module Only (third-party type) 23 HART, Relay, and 4-20 mA 33 Relay and 4-20 mA / NTSC (xWatch) 34 Eagle Quantum Premier / NTSC (xWatch
Multispectrum infrared X3302 Protect•IR Multispectrum Infrared Flame Detector (FM/CSA/ATEX/CE/IECEx) Model Part Number* Material Threads Output Ex d e Ex d FM/CSA/ ATEX/CE/ IECEx Ship Weight X3302A4N13W1 009008-XXX AL 3/4 NPT Relay/4-20 mA X X 6 lb (2.75 kg) X3302A4M13W1 009009-XXX AL M25 Relay/4-20 mA X X 6 lb (2.75 kg) X3302S4N13W1 009010-XXX 316 SS 3/4 NPT Relay/4-20 mA X X 10 lb (4.54 kg) X3302S4M13W1 009011-XXX 316 SS M25 Relay/4-20 mA X X 10 lb (4.
Multispectrum infrared X3302 Protect•IR Multispectrum Infrared Flame Detector – Russia Model Part Number* Material Threads Output Ex d e X3302A4M13R1 009040-XXX AL M25 Relay/4-20 mA X X Ex d VNIIPO/ VNIIFTRI (Russia) X 6 lb (2.75 kg) X 10 lb (4.54 kg) Ship Weight X3302S4M13R1 009041-XXX 316 SS M25 Relay/4-20 mA X3302A4M13R2 009042-XXX AL M25 Relay/4-20 mA X X 6 lb (2.75 kg) X3302S4M13R2 009043-XXX 316 SS M25 Relay/4-20 mA X X 10 lb (4.54 kg) 6 lb (2.
Ultraviolet/infrared X5200 UVIR Flame Detector X5200 UVIR Flame Detector (Spec Sheet: 90-1156) meets the most stringent requirements worldwide with advanced high speed detection capabilities and immunity to extraneous sources, combined with a superior mechanical design. The combination of Arc rejection on the UV sensor and TDSA/Quick on the IR sensor make this detector the highest false alarm immune UVIR available.
Ultraviolet/infrared X5200 Model Matrix MODEL X5200 DESCRIPTION UVIR Flame Detector UVIR Flame Detector X5200M+ with Molybdenum Tube TYPE MATERIAL A Aluminum S Stainless Steel (316) TYPE THREAD TYPE 3M 3 Port, Metric M25 3N 3 Port, 3/4" NPT 4M 4 Port, Metric M25 4N 4 Port, 3/4" NPT TYPE OUTPUTS 11 Relay 13 Relay and 4-20 mA 14 Eagle Quantum Premier 15 Relay and Pulse 16 Addressable Module Only (third-party type) 23 HART, Relay, and 4-20 mA 24 Eagle Quantum 33 Relay and 4-20
Ultraviolet/infrared X5200 UVIR Flame Detector (FM/CSA/ATEX/CE/IECEx) Model Part Number* Material Threads Output Ex d e X5200A4N11W1 X5200A4M11W1 X5200S4N11W1 X5200S4M11W1 008500-XXX 008501-XXX 008502-XXX 008503-XXX AL AL 316 SS 316 SS 3/4 NPT M25 3/4 NPT M25 Relay Relay Relay Relay X X X X X5200A4N11W2 X5200A4M11W2 X5200S4N11W2 X5200S4M11W2 008504-XXX 008505-XXX 008506-XXX 008507-XXX AL AL 316 SS 316 SS 3/4 NPT M25 3/4 NPT M25 Relay Relay Relay Relay X5200A4N13W1 X5200A4M13W1 X5200S4N13W1
Ultraviolet/infrared X5200 UVIR Flame Detector – Brazil Model Part Number* X5200A4N11B2 X5200S4N11B2 X5200A4N13B2 X5200S4N13B2 X5200A4N14B2 X5200S4N14B2 X5200A4N23B2 X5200S4N23B2 X UL/ INMETRO (Brazil) X 6 lb (2.75 kg) X X 10 lb (4.54 kg) Relay/4-20 mA X X 6 lb (2.75 kg) Relay/4-20 mA X X 10 lb (4.54 kg) 3/4 NPT EQP X X 6 lb (2.75 kg) 3/4 NPT EQP X X 10 lb (4.54 kg) AL 3/4 NPT Rly/4-20/HART X X 6 lb (2.75 kg) 316 SS 3/4 NPT Rly/4-20/HART X X 10 lb (4.
Ultraviolet/infrared X5200M UVIR Flame Detector – Moly (FM/CSA/ATEX/CE/IECEx) Model Part Number Material Threads Output X5200MA4N13W1 X5200MA4M13W1 X5200MS4N13W1 X5200MS4M13W1 008540-013 008541-013 008542-013 008543-013 AL AL 316 SS 316 SS 3/4 NPT M25 3/4 NPT M25 Relay/4-20 mA Relay/4-20 mA Relay/4-20 mA Relay/4-20 mA X5200MA4N13W2 X5200MA4M13W2 X5200MS4N13W2 X5200MS4M13W2 008544-013 008545-013 008546-013 008547-013 AL AL 316 SS 316 SS 3/4 NPT M25 3/4 NPT M25 Relay/4-20 mA Relay/4-20 mA Relay/4-
Ultraviolet/infrared Table B1 – X5200 Software Part Number Configuration Matrix UV Arc IR Alarm Output IR Dash Sensitivity Rejection Sensitivity Qualifications Alarm Relay -001 High High High TDSA Only -002 High Very High High TDSA or Quick -003 High Off Very High TDSA or Quick -004 High High Very High TDSA Only -005 Medium High High TDSA or Quick -006 High High Low TDSA Only -007 High High High TDSA Only -008 High Very High High TDSA or Quick -009 High Off Very Hi
Single Frequency infrared X9800 IR Flame Detector The X9800 IR Flame Detector (Spec Sheet: 90-1160) meets the most stringent requirements worldwide with advanced detection capabilities and immunity to extraneous sources, combined with a superior mechanical design. The detector is equipped with dual signal processing (high speed operation) and automatic/magnetic manual oi test capability. The detector has Division and Zone explosion-proof ratings and is suitable for use in indoor and outdoor applications.
Single Frequency infrared X9800 Model Matrix MODEL DESCRIPTION X9800 Single Frequency IR Flame Detector TYPE MATERIAL A Aluminum S Stainless Steel (316) TYPE THREAD TYPE 3M 3 Port, Metric M25 3N 3 Port, 3/4" NPT 4M 4 Port, Metric M25 4N 4 Port, 3/4" NPT TYPE OUTPUTS 11 Relay 13 Relay and 4-20 mA 14 Eagle Quantum Premier 15 Relay and Pulse 16 Addressable Module Only (third-party type) 23 HART, Relay, and 4-20 mA 33 Relay and 4-20 mA / NTSC (xWatch) 34 Eagle Quantum Premier / N
Single Frequency infrared X9800 Single Frequency IR Flame Detector (FM/CSA/ATEX/CE/IECEx) Model Part Number* Material Threads Output Ex d e Ex d FM/CSA/ ATEX/CE/ IECEx Ship Weight 6 lb (2.75 kg) X9800A4N11W1 008700-XXX AL 3/4 NPT Relay X X X9800A4M11W1 008701-XXX AL M25 Relay X X 6 lb (2.75 kg) X9800S4N11W1 008702-XXX 316 SS 3/4 NPT Relay X X 10 lb (4.54 kg) X9800S4M11W1 008703-XXX 316 SS M25 Relay X X 10 lb (4.
Single Frequency infrared X9800 Single Frequency IR Flame Detector – Russia Model Part Number* Material Threads Output VNIIPO/ VNIIFTRI (Russia) Ex d e Ex d Ship Weight X9800A4M11R1 008740-XXX AL M25 Relay X X 6 lb (2.75 kg) X9800S4M11R1 008741-XXX 316 SS M25 Relay X X 10 lb (4.54 kg) X9800A4M11R2 008742-XXX AL M25 Relay X X 6 lb (2.75 kg) X9800S4M11R2 008743-XXX 316 SS M25 Relay X X 10 lb (4.54 kg) X9800A4M13R1 008744-XXX AL M25 Relay/4-20 mA X X 6 lb (2.
Single Frequency infrared X9800 IR Flame Detector – xWatch Camera (FM/CSA) Model Part Number* Material Threads Output Video FM/CSA Ship Weight X9800A3N33A2 X9800A3M33A2 X9800S3N33A2 X9800S3M33A2 009548-XXX 009549-XXX 009550-XXX 009551-XXX AL AL SS SS 3/4 NPT M25 3/4 NPT M25 Relay/4-20 Relay/4-20 Relay/4-20 Relay/4-20 NTSC NTSC NTSC NTSC X X X X 9 lb (4.1 kg) 9 lb (4.1 kg) 14 lb (6.4 kg) 14 lb (6.
Single Frequency infrared Application Recommendations These are typical industry application settings. They may not be applicable to all installations. Contact factory for application guidance. General Duty Offshore Compressor High Speed Hangar Automotive Turbine 001 001 002 003 004 005 006 NOTE: Latching relays cannot be used in voted systems. Notes 8/01/2011 52-1002-8.1 Single Frequency Infrared Flame C.
Ultraviolet X2200 UV Flame Detector X2200 UV Flame Detector (Spec Sheet: 90-1157) meets the most stringent requirements worldwide with advanced signal processing and immunity to extraneous sources, combined with high speed capability. The detector is equipped with both automatic and manual oi test capability. The detector has Division and Zone explosion-proof ratings and is suitable for use in a variety of applications.
Ultraviolet X2200 Model Matrix MODEL X2200 DESCRIPTION UV Flame Detector Flame Detector X2200M+ UV w/Molybdenum Tube TYPE MATERIAL A Aluminum S Stainless Steel (316) TYPE THREAD TYPE 3M 3 Port, Metric M25 3N 3 Port, 3/4" NPT 4M 4 Port, Metric M25 4N 4 Port, 3/4" NPT TYPE OUTPUTS 11 Relay 13 Relay and 4-20 mA 14 Eagle Quantum Premier 15 Relay and Pulse 16 Addressable Module Only (third-party type) 23 HART, Relay, and 4-20 mA 24 Eagle Quantum 33 Relay and 4-20 mA / NTSC (xWatc
Ultraviolet X2200 UV Flame Detector (FM/CSA/ATEX/CE/IECEx) Model Part Number* Material Threads Output Ex d e X2200A4N11W1 X2200A4M11W1 X2200S4N11W1 X2200S4M11W1 008300-XXX 008301-XXX 008302-XXX 008303-XXX AL AL 316 SS 316 SS 3/4 NPT M25 3/4 NPT M25 Relay Relay Relay Relay X X X X X2200A4N11W2 X2200A4M11W2 X2200S4N11W2 X2200S4M11W2 008304-XXX 008305-XXX 008306-XXX 008307-XXX AL AL 316 SS 316 SS 3/4 NPT M25 3/4 NPT M25 Relay Relay Relay Relay X2200A4N13W1 X2200A4M13W1 X2200S4N13W1 X2200S4M13W
Ultraviolet X2200 UV Flame Detector – Brazil Model Part Number* Material Threads Output Ex d e Ex d X2200A4N11B2 X2200S4N11B2 X2200A4N13B2 X2200S4N13B2 008420-XXX 008421-XXX 008422-XXX 008423-XXX AL 316 SS AL 316 SS 3/4 NPT 3/4 NPT 3/4 NPT 3/4 NPT Relay Relay Relay/4-20 mA Relay/4-20 mA X X X X X2200A4N14B2 X2200S4N14B2 X2200A4N23B2 X2200S4N23B2 008424-001 008425-001 008426-XXX 008427-XXX AL 316 SS AL 316 SS 3/4 NPT 3/4 NPT 3/4 NPT 3/4 NPT EQP EQP Rly/4-20/HART Rly/4-20/HART X X X X UL/ S
Ultraviolet X2200M UV Flame Detector – Moly (FM/CSA/ATEX/CE/IECEx) Model Part Number Material Threads Output Ex d e X2200MA4N13W1 X2200MA4M13W1 X2200MS4N13W1 X2200MS4M13W1 008340-013 008341-013 008342-013 008343-013 AL AL 316 SS 316 SS 3/4 NPT M25 3/4 NPT M25 Relay/4-20 mA Relay/4-20 mA Relay/4-20 mA Relay/4-20 mA X X X X X2200MA4N13W2 X2200MA4M13W2 X2200MS4N13W2 X2200MS4M13W2 008344-013 008345-013 008346-013 008347-013 AL AL 316 SS 316 SS 3/4 NPT M25 3/4 NPT M25 Relay/4-20 mA Relay/4-20 mA
Ultraviolet Table D1 – X2200 Software Part Number Configuration Matrix Dash UV Sensitivity Arc Rejection Alarm Relay Aux Output Function Aux Relay Fault Relay -001 High High Follows Alarm -002 High Very High -003 High Off -005 Medium High -006 High High -007 High High -008 High Very High -009 High Off -010 Medium High 011 High High -013* High Off -014* High Off -015 Very High Low -016 Very High Low -017 Very High Off -018 Very High Off -019 Very High
X-series FLAME DETECTOR accessories X-Series Sensor Modules Model Part Number* Material Ex d e X3301 X3301 X3301 X3301 007752-XXX 007753-XXX 007754-XXX 007755-XXX AL AL 316 SS 316 SS X X3301 Automotive X3301 Automotive 007752-005 007753-005 AL AL X X3302 X3302 X3302 X3302 008992-002 008993-002 008994-002 008995-002 AL AL 316 SS 316 SS X X5200 X5200 X5200 X5200 007756-XXX 007757-XXX 007758-XXX 007759-XXX AL AL 316 SS 316 SS X X5200M X5200M X5200M X5200M 011225-013 011226-013 011227-013 0
X-series FLAME DETECTOR accessories X-Series Flame Detector Accessories Model and/or Description Part Number Material Ship Weight Converter RS485 to RS232 Converter RS485 to USB W6300B1002 Inspector Connector, Serial (Inspector Monitor included) W6300B1003 Inspector Connector, USB (Inspector Monitor included) Flame Inspector Monitor CD Model 475 HART Communicator 000511-029 103881-001 007819-001 007819-002 009207-001 103922-001 <1 lb (<0.45 kg) <1 lb (<0.45 kg) <1 lb (<0.45 kg) <1 lb (<0.
X7050 X7050 xWatch® Explosion-Proof Surveillance Camera X7050 xWatch Explosion-Proof Surveillance Camera (Spec Sheet 90-1193) An explosionproof surveillance camera providing high-resolution color images of activity in the monitored area, which allows the capture and recording of fires and other activities on video. When a detector goes into alarm, the operator can immediately view the monitored area in real time and accurately assess the risk and location of the fire.
X7050 X7050 Model Matrix MODEL DESCRIPTION X7050 xWatch Explosion Proof Camera TYPE MATERIAL A Aluminum S Stainless Steel TYPE THREAD TYPE 1E 1/2" NPT 1F M20 TYPE VIDEO OUTPUT 50 NTSC 51 PAL TYPE FIELD OF VIEW 1 Wide FOV (90°), 2.3 mm Lens* 2 Normal FOV (50°), 4.3 mm Lens 3 Narrow FOV (30°), 8.0 mm Lens TYPE W APPROVALS FM/CSA/ATEX/CE TYPE CLASSIFICATION 2 Division/Zone Ex d *This lens emulates the 90° field of view to match the X-Series Flame Detectors.
X7050 X7050 Spare Camera Modules Model Part Number Material Threads FOV Output Ship Weight DE2020N 009448-003 N/A N/A 2.3 mm NTSC 5 oz. (0.14 kg) DE2020P 009448-004 N/A N/A 2.3 mm PAL 5 oz. (0.14 kg) DE2022N 009448-005 N/A N/A 4.3 mm NTSC 5 oz. (0.14 kg) DE2022P 009448-006 N/A N/A 4.3 mm PAL 5 oz. (0.14 kg) DE2023N 009448-007 N/A N/A 8.0 mm NTSC 5 oz. (0.14 kg) DE2023P 009448-008 N/A N/A 8.0 mm PAL 5 oz. (0.
X7050 Notes 8/01/2011 52-1002-8.1 X7050 Flame F.
C7050 C7050 Detector C7050 Detector (Manual: 95-8214) combined with the EQ2200UVHT (95-8570) on an EQP (or as a replacement on an older EQ system) provides fast, reliable flame detection in a wide variety of applications. The detector has the Automatic Optical Integrity (oi) feature, providing a continuous check of detector optical surfaces, detector sensitivity, and electronic circuitry of the detector/controller system. Not recommended for applications where welding or lightning may be present.
C7050 C7050B Model Matrix MODEL DESCRIPTION C7050B Controller Based UV Flame Detector TYPE MATERIAL A Aluminum S Stainless Steel (316) TYPE 6 ENTRY 1 Port TYPE THREAD TYPE E 1/2” NPT F M20 TYPE OUTPUTS Pulse (Standard) 4 TYPE TUBE MODULE OPTION A DE1888A2 (Standard) K DE1888K2 (High Temp) M DE1888M2 (Remote Surveillance, Hydrogen Fires) N DE1888N2 (High Sensitivity, Special App) T DE1888T2 (Electrostatic App) V DE1888V2 (Internal Reflection) W DE1888W2 (Remote Surveillance, Redu
Dual Spectrum Infrared Det-Tronics PM-5MPX Dual Spectrum Flame Detector Det-Tronics PM-5MPX Dual Spectrum Flame Detector (Spec Sheet: 90-1182) is optimized for the rigorous semiconductor fabrication industry, which is beset with many hazards that result in stringent and application-specific requirements for fire protection safety systems.
Dual Spectrum Infrared PM-5MPX Dual Spectrum IR Flame Detector for Semiconductor Fabrication Tools Model Part Number Encl Material Cable Length FM Ship Weight PM-5MPX 421132-001 Polypropylene 50 ft X 0.5 lb (0.23 kg) Dual Spectrum PM-5MPX Accessories Part Number Description Ship Weight 007351-001 PSS-ML PSS-MP Test Lamp (PM-5SX, PM-5MP, PM-5MP+, PM-5MPX, PM-6M, PM6MX) PSS-MP Replacement Bulb <1 lb (<0.45 kg) 420116-001 421129-001 1 lb (0.46 kg) <1 lb (0.
High-Speed Infrared C7093/R7094 High-Speed Infrared Flame Detection System The C7093/R7094 High-Speed Infrared Flame Detection System (Spec Sheet: 90-1028) responds in less than 5 milliseconds to a high-intensity flash fire. Designed specifically for applications such as munitions manufacturing, the C7093/R7094 can trigger high-speed extinguishing systems.
High-Speed Infrared C7093 High-Speed Infrared Fire Detector Model Part Number Enclosure Material Conduit Entry Cable Length Ship Weight C7093D6025 C7093E8010 004083-006 004083-102* 316 SS 316 SS 1/2 in 1/2 in 25 ft 10 ft 2.75 lb (1.24 kg) 2.75 lb (1.24 kg) *Aliant Tech Model. C7093 Test Lamp Model Part Number Ship Weight PSS-ML 007351-001 <1 lb (<0.45 kg) R7094 High Speed Infrared Detection Controller Model Part Number Mounting Ship Weight R7094A2001 003703-001 Rack 4.4 lb (2.
Smoke Detectors U5005 and U5006 Smoke Detectors U5005 Smoke Detector (Spec Sheet: 90-1101) is a sensitive, yet rugged, state-of-the-art protection device that is designed for classified areas in hazardous industrial and commercial locations. The detector is designed to operate effectively with both slow smoldering and fastburning fires. Includes an external alarm indicating LED and one set of normally open relay contacts for alarm and one set of normally closed relay contacts for power supervision.
Smoke Detectors U5005 Smoke Detector Model Part Number Housing Material U5005A1001 U5005A1002 U5005A1004 U5005A1001-R U5005A1004-R 004784-007 004784-008 004784-009 004784-908 004784-909 AL AL AL AL AL J-box Material # of Ports Conduit Entry AL AL AL AL AL 1 2 4 1 4 3/4” NPT* 3/4” NPT* 3/4” NPT* M25 M25 CSA VNIIPO/ VNIIFTRI (Russia) X X X Ship Weight 2 lb (0.91 kg) 2 lb (0.91 kg) 2 lb (0.91 kg) 2 lb (0.91 kg) 2 lb (0.91 kg) X X *Uses a permanently installed M25 to 3/4” NPT adapter.
Accessories Test Lamps W8066 Portable UV Test Lamp (Spec Sheet: 90-1055) is used for on-site testing of all UV detector types. It replaces W866. Consists of a UV lamp powered by a replaceable 9 volt battery and is contained in a plastic enclosure. Intrinsically safe. W867C Portable UV/IR Test Lamp (Spec Sheet: 90-1055) is used for on-site testing of UV, single frequency IR, or UVIR detectors.
Accessories Laser, Laser Holder, W6300 Detector Inspector Laser is for use with the Q1201A and Q1201C Laser Holder in sighting and testing the area of flame detection coverage. Battery-powered laser projects a red beam of light and has a toggle switch for turning the device on and off. When used with its holder, the laser beam identifies the center and edges of the detector’s COV. Includes battery.
Accessories Detector Hardware Q1113A Universal Air Shield Assembly (Manual: 95-8321). Use on UV, IR, and UV/IR detectors (C7050A, B and H, C7051, C7052, C7098, U7600, U7602 and U7698) in areas with high levels of airborne contamination. Consists of Delrin (solvent-resistant plastic) air shield housing with bronze sintered air diffuser. Quick connect air line fitting accepts 1/4 inch O.D. nylon tubing for instrument grade air supply of 5 to 15 psi at 3 or more cubic feet per minute.
Accessories Q1113 Universal Air Shield Assembly Model Part Number Air Connection Air Supply Air Requirement Ship Weight Q1113A1001 004273-002 1/4 in OD nylon tubing 5-15 psi 3 cfm minimum 1 lb (0.45 kg) Q1115 Universal Air Shield/Range Mount Assembly Model Part Number Material Air Connection Air Supply Air Requirement Q1115A1001 006528-001 SS 1/4 in OD nylon tubing 5-15 psi 3 cfm minimum 2 lb (0.
Accessories Detector Mounting Hardware Q9001B (Manual: 95-8338) Aluminum swivel for positioning the C7050 and X7050. Q9001H (Manual: 95-8338) Stainless steel swivel for positioning the C7050 and X7050. Q9033A Aluminum swivel for X3301, X3302, X2200, X5200, and X9800. NOTE: For use with aluminum body detectors only. Q9033B Stainless steel swivel for X3301, X3302, X2200, X5200, and X9800.
Accessories Power Supplies 000507-005 and 000507-006 24 Vdc Power Supplies (Spec Sheet: 90-1035). Open frame construction and designed to operate on 120/240 Vac 50/60 Hz to handle the power requirements of IR detection systems, UV/IR detection systems, and larger UV detection systems that typically need higher levels of current than rack-mounted voltage converters can deliver. Use in Q1020 Wall mount enclosures (sold separately) or in other enclosures containing Det-Tronics’ fire detection equipment.
Accessories Output Devices for R7XXX Controllers R1425 Rack Mount Detonator Module (Spec Sheet: 90-1021) for high-speed extinguishing systems. Features two independent capacitive-discharge detonator firing circuits monitored for opens. Use with the R7404 controller. Mounts in Q4004 Cage Assembly (sold separately). Operates on 12 or 24 Vdc. R1425 Rack Mount Detonator Module for the R7404 Controller Model Part Number Description Ship Weight R1425A2024 002791-001 3 lb (1.
Accessories Notes 8/01/2011 52-1002-8.1 Accessories Flame K.
Controllers R74XX Controllers The R7404 Controller (Spec Sheet: 90-1014) provide fast, reliable flame detection in a wide variety of applications. The microprocessor-based controller simultaneously monitors up to 16 C7050 ultraviolet detectors in up to eight different zones. The detector has the Automatic Optical Integrity (oi) feature, providing a continuous check of detector optical surfaces, detector sensitivity, and electronic circuitry of the detector/controller system. Selectable time delay.
Controllers R7404 UV Fire Detection Controller Model Part Number Channels Backplate Connector STAR Logic R7404B7001 R7404B7003* R7404B7004 002257-001 002257-006 002257-007 8 8 8 X X X High Speed FM CSA Ship Weight X X X X X X X 4.4 lb (2.0 kg) 4.4 lb (2.0 kg) 4.4 lb (2.0 kg) *Star logic controllers are recommended for outdoor applications. NOTE: R7404C5020 replaced by R7404B7001.
Spare parts Spare and Replacement Parts PM-9SBE Replacement Parts Part Number Description Ship Weight 412291-001 411288-004 411288-001 411288-002 411288-005 411288-003 421368-001 411833-001 Electronic assembly (PM-9SBE) Fiber optic cable (10 foot) Fiber optic cable (30 foot) Fiber optic cable (45 foot) Fiber optic cable (60 foot) Fiber optic cable (100 foot) Fiber optic sensor head (conductive) PSS-F test lamp (PM-9CBE, PM-9SBE) 2.5 lb (1.2 kg) 2.5 lb (1.2 kg) 2.5 lb (1.2 kg) 2.5 lb (1.2 kg) 2.5 lb (1.
Spare parts UV Sensor Modules Model Part Number DE1888A2 003240-201 DE1888B2 003240-202 DE1888B3 DE1888G2 003240-218 003240-207 DE1888K2 003240-210 DE1888K3 003240-221 DE1888M2 003240-212 DE1888N 003240-013 DE1888N2 003240-213 DE1888T2 004433-201 DE1888U2 DE1888V2 DE1888V3 DE1888W2 003240-220 003240-217 003240-219 004433-204 Comments Replaces DE1666A, DE1666C, DE1777A, DE1777C, DE1888A Replaces DE1666B, DE1777B, DE1777D, DE1888D, DE1888B LED for VdS approved devices Nuclear remote sur
Spare parts Backplate Terminal Connectors Use With Part Number Replaces Ship Weight R1425 R6006 R6007 R7094 R7404, R7409, R7484, R7494 W4220 002805-001 002296-001 003356-001 003715-001 002242-001 002224-001 003551-001, 003957-001 - 1 lb (0.45 kg) 1 lb (0.45 kg) 1 lb (0.45 kg) 1 lb (0.45 kg) 1 lb (0.45 kg) 1 lb (0.
Spare parts Notes 8/01/2011 52-1002-8.1 Spare Parts Flame M.
Table of contents GAS PointWatch Eclipse® PIRECL Infrared Hydrocarbon Gas Detector . . . . . . . . . . . . . . . . Gas A.1 PointWatch Eclipse Model Matrix . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Typical PIRECL Customer Proposal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Table of contents GAS CONTINUED... PIRDUCT IR Gas Monitor. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Gas A.23 PIRDUCT Model Matrix. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Gas A.24 PIRDUCT Models. . . . . . . . . . . . . . . . .
Table of contents GAS CONTINUED... Model 505 Combustible Transmitter (includes junction box, sensor ordered separately). . . . . . Gas B.9 Model 505 Model Matrix . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Model 505 Combustible Transmitter and Junction Box. . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Table of contents GAS CONTINUED... FlexVu UD10 Universal Display (for Toxics) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Gas C.9 FlexVu UD10 Model Matrix . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . FlexVu UD10 Universal Display – Toxics. . . . . . . . . . . . . . . . . . . .
Table of contents GAS CONTINUED... FlexVu UD20 Universal Display. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Gas D.5 FlexVu UD20 Model Matrix . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . FlexVu UD20 Universal Display. . . . . . . . . . . . . . . . .
infrared PointWatch Eclipse® PIRECL Infrared Hydrocarbon Gas Detector The PointWatch Eclipse PIRECL Hydrocarbon Detector (Spec Sheet: 90-1138) is our most rugged stainless steel, point infrared gas detector providing detection of methane, propane, and ethylene, among other flammable hydrocarbon gases in the LFL range. Standard signal outputs include isolated 4-20 mA output, HART communication protocol, and RS-485 serial communication supporting Modbus.
infrared PointWatch Eclipse Model Matrix MODEL DESCRIPTION PIRECL Point Infrared Eclipse Gas Detector TYPE THREAD TYPE A 3/4” NPT B M25 TYPE OUTPUT AND MEASUREMENT OPTIONS 1 4-20 mA with HART Protocol and RS-485: 0-100% LFL Full Scale Range 4 Eagle Quantum Premier Compatible Only: 0-100% LFL Full Scale Range TYPE OPTIONAL OUTPUTS A HART Communication Port B HART Communication Port and Relay Board (not compatible with EQP) Ex d only D No Optional Outputs E Relay Board (not compatible with
infrared 4-20 mA 4-20 mA 4-20 mA 4-20 mA 4-20 mA 4-20 mA 4-20 mA 4-20 mA 4-20 mA 4-20 mA 4-20 mA 4-20 mA 4-20 mA 4-20 mA 4-20 mA 4-20 mA 4-20 mA 4-20 mA 4-20 mA X X X X X X X X X X X X X X X X X X X PIRECLA4A3W1 PIRECLA4A3W2 PIRECLA4A1W1 PIRECLA4A1W2 PIRECLA4A2W1 PIRECLB4A3W1 PIRECLB4A3W2 PIRECLB4A1W1 PIRECLB4A1W2 PIRECLB4A2W1 007168-016 007168-044 007168-012 007168-043 007168-014 007168-017 007168-048 007168-013 007168-047 007168-015 3/4 NPT 3/4 NPT 3/4 NPT 3/4 NPT 3/4 NPT M25 M25 M25 M25 M25 EQP EQP
infrared Part number* Entry thread type Output HART Port Relays Weather protection** PIRECLA1A1T1 PIRECLA1A1T2 PIRECLA1A2T1 PIRECLA1B1T2 PIRECLA1B2T2 PIRECLA1A3T1 PIRECLA1A3T2 PIRECLB1A1T1 PIRECLB1A1T2 PIRECLB1A2T1 PIRECLB1A2T2 PIRECLB1B1T2 PIRECLB1B2T2 PIRECLB1A3T1 PIRECLB1A3T2 007168-201 007168-241 007168-203 007168-205 007168-207 007168-210 007168-242 007168-202 007168-245 007168-204 007168-218 007168-206 007168-227 007168-240 007168-246 3/4 NPT 3/4 NPT 3/4 NPT 3/4 NPT 3/4 NPT 3/4 NPT 3/4 NPT M2
infrared 4-20 mA 4-20 mA EQP 4-20 mA 010195-020 010195-051 010195-220 3/4 NPT 3/4 NPT 3/4 NPT 4-20 mA EQP 4-20 mA Part number* PIRECLA1A1B2 PIRECLA1B1B2 PIRECLA4A1B2 PIRECLA1A1BT2 PIRECLA1D1B2 PIRECLA4D1B2 PIRECLA1D1BT2 Output HART Relays Port X X X X Weather protection* Ex d 007168-020 007168-021 007168-051 007168-220 Entry thread type 3/4 NPT 3/4 NPT 3/4 NPT 3/4 NPT Model Ex d e PointWatch Eclipse Models – Brazil Approvals Ship Weight No Yes No No w/ hydrophobic w/ hydrophobic w/ hydroph
infrared Notes 8/01/2011 52-1002-8.1 Infrared Gas A.
infrared PIRECL Accessories and Sample Draw The Model 475 HART Field Communicator is available from Detector Electronics Corporation under agreement with Emerson Process Management. The intrinsically safe 475 Field Communicator enables connection to the PIRECL via the onboard optional HART port connection. Features include a full color LCD display, 4x battery life and half the start up time from previous releases.
infrared Miscellaneous PIRECL Accessories 475 HART Communicator Part Number 103922-001 103922-002 103922-903 103922-904 Description 475 HART Field Communicator 475 HART & Foundation Fieldbus Field Communicator 475 HART Field Communicator, Russian 475 HART & Foundation Fieldbus Field Communicator, Russian Ship Weight 7.5 lb (3.4 kg) 7.5 lb (3.4 kg) 7.5 lb (3.4 kg) 7.5 lb (3.
infrared Duct-Mounting Kits for PIRECL PointWatch Eclipse The Direct Duct Mount Assembly (p/n 007525-XXX series) (Spec Sheet: 90-1151) is FM approved for use with model PIRECL PointWatch Eclipse to be installed directly within air handling ductwork. The assembly is mounted on the duct wall, with the PIRECL sensing chamber exposed directly to duct airflow, ensuring fast response to Methane.
infrared Model Q900 Inlet Tubes Part Number Material Ship Weight Length 000214-281 000214-282 000214-283 000214-284 000214-285 000214-280* 316 SS 316 SS 316 SS 316 SS 316 SS 316 SS 8 oz (0.23 kg) 1 lb (0.45 kg) 3 lb (1.35 kg) 6 lb (2.4 kg) 9 lb (4.0 kg) 8 oz (0.23 kg) 1 ft 3 ft 6 ft 10 ft 13 ft 1 ft *Return tube Notes 8/01/2011 52-1002-8.1 Infrared Gas A.
infrared PointWatch PIR9400 IR Hydrocarbon Gas Detector PointWatch PIR9400 Infrared Hydrocarbon Detector (Spec Sheet: 90-1074). Approved for methane combustible gas. Provides reliable operation in high concentrations of background hydrocarbon gases and has low maintenance costs. It is immune to poisoning. Five year warranty. • • • PointWatch PIR9400 Gas A.11 UD10 Universal Display Gas A.15 CONTROLLERS DISPLAY/ TRANSMITTER DETECTOR • • • • • • • • • Compliance to ANSI/ISA-12.13.
infrared PointWatch PIR9400 Model Matrix MODEL DESCRIPTION PIR9400 PointWatch Gas Detector TYPE DETECTOR BODY MATERIAL A Aluminum S Stainless Steel TYPE THREAD TYPE 2 Metric M20 3 3/4” NPT TYPE WEATHER BAFFLE MATERIAL A Aluminum P Polyphthalamide Plastic TYPE HYDROPHOBIC FILTER 1 Factory-Fitted Hydrophobic filter 2 No hydrophobic filter TYPE LEAD WIRE LENGTH A 22 inch B 44 inch TYPE APPROVALS W FM/CSA/ATEX/CE/IECEx R vniiftri (Russia) B INMETRO (Brazil) PointWatch PIR9400 Mo
infrared PointWatch PIR9400 Spare Parts & Accessories The PIR9400 Sample Draw Cup (Manual 95-8486) provides a sealed metal enclosure enabling use of PointWatch PIR9400 within a gas sample extraction system (not included). Requires removal of standard baffle and some field assembly. Not compatible with PointWatch Eclipse. PointWatch Sample Draw Cup Part Number Compression Fitting Material Ship Weight 006629-002 006629-004 X X AL SS 2.0 lb (0.95 kg) 4.7 lb (2.2 kg) NOTE: PointWatch is not included.
infrared Notes 8/01/2011 52-1002-8.1 Infrared Gas A.
infrared FlexVu ® UD10 Universal Display (for Infrared) FlexVu UD10 Universal Display (Spec Sheet: 90-1200) is recommended for applications where a gas detector with digital read-out of detected gas levels are required. The FlexVu UD10 Universal Display Unit is designed for use with Det-Tronics’ infrared gas sensor/transmitters such as PIRECL, PIR9400, PIRDUCT, or OPECL.
infrared FlexVu UD10 Model Matrix MODEL DESCRIPTION UD10 Universal Display Unit TYPE MATERIAL A Aluminum S Stainless Steel (316) TYPE THREAD TYPE 5M 5 Port, Metric M25 5N 5 Port, 3/4” NPT TYPE OUTPUTS 25 Relay, 4-20 mA, RS485, HART 27 Relay, 4-20 mA, HART, Foundation Fieldbus (FF) 28 EQP / DCU Emulator TYPE APPROVALS W FM/CSA/ATEX/CE/IECEx B INMETRO (Brazil) R VNIIFTRI (Russia) TYPE CLASSIFICATION (Div/Zone) Ex d (Flameproof) 2 FlexVu UD10 Universal Display – Infrared (FM/CSA/ATE
infrared UD10 Universal Display – Infrared (Russia) Model Part Number Material Threads UD10A5M25R2 UD10A5N25R2 UD10S5M25R2 UD10S5N25R2 UD10A5M28R2 UD10A5N28R2 UD10S5M28R2 UD10S5N28R2 010765-901 010765-902 010765-903 010765-904 010765-905 010765-906 010765-907 010765-908 AL AL 316 SS 316 SS AL AL 316 SS 316 SS M25 3/4 NPT M25 3/4 NPT M25 3/4 NPT M25 3/4 NPT Relay 4-20 RS485 HART X X X X EQP/ DCU Emulator VNIIFTRI (Russia) Ship Weight X X X X X X X X X X X X 4.2 lb (1.9 kg) 4.2 lb (1.9 kg) 10.
infrared Notes 8/01/2011 52-1002-8.1 Infrared Gas A.
infrared U9500H Infiniti ® HC–PointWatch Transmitter U9500H Infiniti HC–PointWatch Transmitter (Spec Sheet: 90-1099). For use with a single Det-Tronics PointWatch Eclipse or PIR9400 Infrared Hydrocarbon gas detector. The U9500 is approved as a stand-alone combustible gas and low concentration toxic controller, when using the relay contacts. Performance certified to ATEX EN60079-29-1, FM 6310/6320, and CSA 22.
infrared U9500 Infiniti Model Matrix MODEL U9500 DESCRIPTION Infiniti Gas Transmitter TYPE GAS IR Combustible H60 TYPE OUTPUT 01 or 02 4-20 mA Relay and 4-20 mA 04 U9500H Infiniti PIR9400 Transmitters (U9500 junction box must be ordered separately) Model Part Number U9500H6002 U9500H6004 U9500H6002-R U9500H6004-R 006265-003 006265-009 006265-903 006265-909 Relays FM/CSA/ ATEX/CE/ IECEx X X X X RUS Ship Weight X X 1 lb (0.46 kg) 1 lb (0.46 kg) 1 lb (0.46 kg) 1 lb (0.
infrared Model PIRTB Series PointWatch Termination Box Use for stand-alone PointWatch Required for remote separation from U9500H transmitter Use with PIRECL Eclipse or PIR9400 when remote calibration initiation is required Magnetic reed switch calibration and LED gives calibration feedback Tall cover boxes with window enable one person, non-intrusive calibration Short cover boxes without window require two people to accomplish non-intrusive calibration CONTROLLERS DISPLAY/ TRANSMITTER DETECTOR • • • • •
infrared PIRTB Junction Box Model Matrix (for use with PIRECL and PIR9400) MODEL DESCRIPTION PIRTB PointWatch Termination Box TYPE MATERIAL A Aluminum S Stainless Steel TYPE 5 # OF OPEN PORTS 5 Port TYPE THREAD TYPE L Metric M25 N 3/4” NPT TYPE APPROVAS FM/CSA/ATEX/CE/IECEx W TYPE COVER TYPE 1 Short without window 3 Tall straight with window TYPE CABLE ENTRIES V Ports 2 thru 6 open PIRTB Series Termination Boxes Model Part Number Material Conduit Entry FM/CSA/ ATEX/CE/ IECEx Cov
infrared PIRDUCT IR Gas Monitor The Model PIRDUCT DuctWatch (Spec Sheet: 90-1188) is an infrared (IR) based flammable gas detection/monitoring solution ideal for combustion turbine enclosure detection/monitoring and sample air handling ductwork applications. The DuctWatch is easy to install and commission, and does not require expensive extractive sampling system hardware.
infrared PIRDUCT Model Matrix MODEL DESCRIPTION PIRDUCT Point Infrared DuctWatch Gas Monitor TYPE THREAD TYPE A 3/4” NPT B M25 TYPE SIGNAL OUTPUT 4-20 mA with Hydrophobic filter 2 TYPE W APPROVALS FM/CSA/ATEX/CE/IECEx TYPE WIRING TERMINATION JUNCTION BOX 1 Factory-fit with PIRTBA5NW3V (std 4-20 mA), AL, 3/4”NPT cable entry 2 Factory-fit with PIRTBA5LW3V (std 4-20 mA), AL, M25 cable entry 3 Factory-fit with EQ2253DCU (EQP sys only), AL, 3/4”NPT cable entry 4 Factory-fit with EQ2207DCU (EQ
infrared PointWatch PIR9400, PointWatch Eclipse and PIRDUCT Certified Calibration Kits PointWatch PIR9400, PointWatch Eclipse and PIRDCUT Certified Calibration Kits are high accuracy compressed gas calibration kits provided for field calibration of all PointWatch IR detectors. Each kit includes: • • • • Two 3.6 ft3 (103 liters) cylinders of specified gas A 2.
infrared PIR9400 and PIRECL Calibration Kits Part Number 006468-006 006468-002 006468-003 006468-007** 006468-014 006468-914* 006468-001 006468-906* 006468-015 006468-915* 006468-004 006468-005 006468-016 Gas %LFL % Vol Butane 50% 0.95 Ethane 50% 1.5 Ethylene 50% 1.35 Methane 7.5% 0.375 Methane 50% 2.2 Methane 50% 2.2 Methane 50% 2.5 Methane 50% 2.5 Propane 50% 0.85 Propane 50% 0.85 Propane 50% 1.1 Propylene 50% 1 Empty kit - no cal gas Ship Weight 11.5 lb (5.23 kg) 11.5 lb (5.23 kg) 11.5 lb (5.23 kg) 11.
infrared Open Path Eclipse OPECL Infrared Gas Detection System The Open Path Eclipse Infrared Gas Detection System (Spec Sheet: 90-1159) is a stainless steel, IR beam-type hydrocarbon gas detection system.
infrared Open Path Eclipse Model Matrix MODEL DESCRIPTION OPECL Open-Path Eclipse Infrared Gas Detector TYPE S MATERIAL Stainless Steel TYPE CONDUIT ENTRY THREAD TYPE 2M 2 Port, Metric M25 2N 2 Port, 3/4” NPT TYPE OUTPUT 00 None (Transmitter Only) 14 Eagle Quantum Premier (EQP) (Receiver or Kit) 18 4-20 mA, RS485, HART (Receiver or Kit) 25 4-20 mA, RS485, HART w/Optional Relay Board (Receiver or Kit) - Ex d only TYPE APPROVALS W FM/CSA/ATEX/CE/IECEx B INMETRO (Brazil) R VNIIFTRI (Ru
infrared Transmitter Replacement Model Part Number Threads Ex de OPECLS2N00W1T OPECLS2M00W1T OPECLS2N00W2T OPECLS2M00W2T OPECLS2M00R1T OPECLS2M00R2T OPECLS2N00B2T 007914-052 007914-053 007914-056 007914-057 007914-953 007914-957 007914-156 3/4 NPT M25 3/4 NPT M25 M25 M25 3/4 NPT X X Ex d X X X FM/CSA/ ATEX/CE/ IECEx X X X X X X VNIIFTRI INMETRO (Russia) (Brazil) X X Shipping Weight 30 lb (34 kg) 30 lb (34 kg) 30 lb (14 kg) 30 lb (14 kg) 30 lb (34 kg) 30 lb (14 kg) 30 lb (14 kg) X NOTE: Spar
infrared Notes 8/01/2011 52-1002-8.1 Infrared Gas A.
infrared PIRVOL Infrared Hydrocarbon Gas Process Monitor PIRVOL Infrared Hydrocarbon Gas Process Monitor (Spec Sheet: 90-1137) is a point-type, hazardous location rated infrared gas process monitor designed for use in extractive vapor sampling applications. All PIRVOL models provide a continuous 4-20 milliampere signal output that is proportional to a 0-90% for VR and 0-100% for LT and HV, by volume hydrocarbon vapor concentration.
infrared PIRVOL Model Matrix MODEL DESCRIPTION PIRVOL Point Infrared Volumetric Gas Process Monitor TYPE APPLICATION LT Light Hydrocarbon HV Heavy Hydrocarbon VR Vapor Recovery TYPE MATERIAL A Aluminum S Stainless Steel TYPE THREAD TYPE 2 M20 3 3/4” NPT TYPE SAMPLING CUP A with Sampling Cup B without Sampling Cup (for replacement only) TYPE APPROVALS C CSA E ATEX/CE PIRVOL Model Listings PIRVOL Light Hydrocarbon Measurement Models (0-100%) Model PIRVOLLTA3AC PIRVOLLTA2AC PIRVOLLTS3AC PIRVOLLTS2AC Part Num
Catalytic Combustible Gas Sensor (CGS) Combustible Gas Sensor (CGS) (Spec Sheet: 90-1041). Stainless steel catalytic sensor that provides an accurate measurement of combustible gas concentration in the % LFL range. Requires FlexVu UD10, Model 505, U9500A or DCUEX transmitter. Compliance to ANSI/ISA-12.13.01-2000 performance standard Performance certified to FM 6310/6320, CSA 22.
Catalytic Combustible Gas Sensor for Models 505, 500, and K-Series (constant voltage) Transmitters Model Part Number Replaces old catalytic sensor p/n Threads Lead Length FM/CSA/ ATEX/CE CGSS1A6V2R1X 006824-002 225006-002, 225957-001, 226530-001, 226531-001, 226931-001, 226931-002, 226999-002, 226999-004, 223106-002 3/4 NPT 6 in X 3/4 NPT 30 in X 20 mm 30 in X 20 mm 6 in X 20 mm 6 in CGSS1A3V2R1X 006824-006 CGSS1C3V2R1X 006824-008 CGSS1C6V2R1X 006824-004 CGSS1C6V2R1R 006824-904
Catalytic FlexVu ® UD10 Universal Display (for Catalytic) FlexVu UD10 Universal Display (Spec Sheet: 90-1200) is recommended for applications where a gas detector with digital read-out of detected gas levels are required. The FlexVu UD10 Universal Display Unit is designed for use with Det-Tronics’ catalytic gas sensor/transmitters such as Model 505 or CGS. The display unit is designed and approved as a stand-alone device and performs all the functions of a gas controller. • • Compliance to ANSI/ISA-12.13.
Catalytic FlexVu UD10 Model Matrix MODEL UD10 DESCRIPTION Universal Display Unit TYPE MATERIAL A Aluminum S Stainless Steel (316) TYPE THREAD TYPE 5M 5 Port, Metric M25 5N 5 Port, 3/4” NPT TYPE OUTPUTS 25 Relay, 4-20 mA, RS485, HART 27 Relay, 4-20 mA, HART, Foundation Fieldbus (FF) 28 EQP / DCU Emulator TYPE Approvals W FM/CSA/ATEX/CE/IECEx B INMETRO (Brazil) R VNIIFTRI (Russia) TYPE CLASSIFICATION (Div/Zone) Ex d (Flameproof) 2 TYPE OPTIONAL CONDITION BOARD CGS C FlexVu UD10
Catalytic FlexVu UD10 Universal Display – CGS (Russia) Model Part Number Material UD10A5M25R2C UD10A5N25R2C UD10S5M25R2C UD10S5N25R2C UD10A5M28R2C UD10A5N28R2C UD10S5M28R2C UD10S5N28R2C 010254-901 010254-902 010254-903 010254-904 010254-905 010254-906 010254-907 010254-908 AL AL 316 SS 316 SS AL AL 316 SS 316 SS Relay EQP/ 4-20 Threads RS485 DCU HART Emulator M25 X 3/4 NPT X M25 X 3/4 NPT X M25 X 3/4 NPT X M25 X 3/4 NPT X Cond.
Catalytic Stop Plugs and Reducers Part Number Description Ship Weight 101197-001* 101197-004* 103517-001 101197-003 010816-001 010817-001 010818-001 010819-001 102804-001 102804-003 Stop Plug, 3/4” NPT, AL Stop Plug, 3/4” NPT, SS Stop Plug, M25, AL, IP66 Stop Plug, M25, SS, IP66 Stop Plug, 20 Pack, 3/4”NPT, AL Stop Plug, 20 Pack, 3/4”NPT, SS Stop Plug, 20 Pack, M25, AL,IP66 Stop Plug, 20 Pack, M25, SS,IP66 Reducer, M25 to M20, AL Reducer, M25 to M20, SS <1 lb (<0.45 kg) <1 lb (<0.45 kg) <1 lb (<0.
Catalytic U9500A Infiniti Combustible Transmitters (sensor and junction box ordered separately) U9500A Infiniti Combustible Transmitters (Manual: 95-8444). For use with CGS, the Infiniti provides an analog signal output and onboard readout of detected gas level. A number of optional features are also available. The U9500 is certified as a stand-alone gas controller for combustible and low concentration gas when used with the CGS.
Catalytic U9500 Infiniti Model Matrix MODEL U9500 DESCRIPTION Infiniti Gas Transmitter TYPE GAS A10 Catalytic Combustible TYPE OUTPUT 01 or 02 4-20 mA 04 Relay and 4-20 mA U9500A Infiniti Combustible Gas Transmitter (junction box and sensor must be ordered separately) Model Part Number U9500A1001 U9500A1004 U9500A1001-R U9500A1004-R 006265-001 006265-007 006265-901 006265-907 Relays FM/CSA/ ATEX/CE/ IECEx X Russian Ship Weight X X 1 lb (0.46 kg) 1 lb (0.46 kg) 1 lb (0.46 kg) 1 lb (0.
Catalytic Model 505 Combustible Transmitter (includes junction box, sensor ordered separately) Model 505 Combustible Transmitter (Spec Sheet: 90-1114). Designed for use with CGS sensor, the 505 provides an analog signal output representing detected gas concentration. The 505 is always used with a gas controller. • Compliance to ANSI/ISA-12.13.
Catalytic Model 505 Model Matrix MODEL 505 DESCRIPTION Catalytic Combustible Gas Transmitter TYPE Material A Aluminum S Stainless Steel Type Conduit Entries and Orientation 2 2-ports, ST-straight-through config (180 degree orientation) 3 2-ports, L-configuration (90 degree orientation) 4 3-ports, T-configuration 5 5-ports Type Thread Type A 3/4" NPT C Metric M20/M25 Type Output 2 4-20 mA TYPE Signal Loop Impedance A 0-125 ohms (replaces K series) B 100-500 ohms (replaces Model 500) Type Classification 1 Ex
Catalytic Combustible Gas Certified Calibration Kits Combustible Gas Certified Calibration Kits (Spec Sheet: 90-1059) for combustible gas sensors. Kits include sturdy plastic carrying case containing: Two 3.
Catalytic Combustible Gas Certified Calibration Kits Model Listing and Accessories Calibration Kits for Catalytic Sensor Part Number 225130-002 225130-902* 225130-003 225130-005 225130-006 225130-007 225130-008 225130-014 225130-914* 225130-001 225130-901* 225130-015 225130-915* 225130-004 225130-009 Gas LFL % Vol Ethane 50% 1.5 Ethane 50% 1.5 Ethylene 50% 1.35 Hydrogen 50% 2.0 Methane 20% 1.0 Methane 25% 1.25 Methane 35% 1.75 Methane 50% 2.2 Methane 50% 2.2 Methane 50% 2.5 Methane 50% 2.
Catalytic Model STB Series Sensor Termination Box and Separation Kit Model STB Series Sensor Termination Box and Separation Kit includes a junction box, proper connector board required hardware.
Catalytic STB Model Matrix Model STB Description Sensor Termination Box Type Compatibility 1 CGS for FlexVu UD10 or model 505 transmitter 2 CGS for U9500A transmitter or DCUEX 3 Model C706x electrochemical gas sensor/transmitter 5 12 terminal 7 Model GT3000 Toxic Gas Detectors Type A S Material Aluminum Stainless Steel # of Ports, thread type TYPE 2M 2 PORT, M20/M25 at 90 degree orientation 2N 2 PORT, 3/4” NPT at 90 degree orientation 2S 2 PORT, M20 at 180 degrees vertical 2U 2 PORT, 3/4” NPT at 180 de
Catalytic Duct Mount and Sample Draw Assemblies for CGS Direct Duct Mount Assembly (Spec Sheet: 90-1046). For mounting combustible sensors to air handling duct work. The Direct Duct Mount CGS assembly enables combustible gas detection in air handling, heating, ventilating, and air conditioning ducts. Designed for flat surface mounting only.
Catalytic CGS Accessories: Rain Shields, Splash Guards, Dust Covers, Remote Calibration Cups Rain Shields (Spec Sheet: 90-1046) protect combustible sensors from rain and snow. Splash Guards (Spec Sheet: 90-1046) protect combustible sensors from ingress due to rain or splashing water. Dust Covers (Spec Sheet: 90-1046) are recommended to protect sensors in windy, dusty, and oily environments. Porex and stainless steel filters available.
toxics GTS Toxic Gas Sensor Module (GT3000 Series) GTS Toxic Gas Sensor Module (Spec Sheet: 90-1199) housings are incorporated into the GTX toxic gas transmitter, the electrochemical cell is embedded in the module.
Toxics GTS Toxic Gas Sensor Module ppm Range Model Number Part Number Toxic Gas GTSH2S20P GTSH2S50P GTSH2S100P GTSCL210P GTSNH3100P GTSNH3500P GTSH21000P GTSO225V GTSCO100P GTSCO500P GTSSO220P GTSSO2100P 009471-001 009471-002 009471-003 009471-004 009471-005 009471-006 009471-008 009471-009 009471-010 009471-011 009471-013 009471-014 Hydrogen Sulfide Hydrogen Sulfide Hydrogen Sulfide Chlorine Ammonia Ammonia Hydrogen Oxygen Carbon Monoxide Carbon Monoxide Sulfur Dioxide Sulfur Dioxide 0 - 20 0 - 50 0
toxics GTX Toxic Gas Transmitter (GT3000 Series) GTX Toxic Gas Transmitter (Spec Sheet: 90-1199). Stainless steel, toxic gas transmitter that provides an accurate measurement of toxic gasses.
Toxics GTX Model Matrix MODEL DESCRIPTION GTX Toxic Gas Transmitter TYPE S MATERIAL Stainless Steel (316) TYPE THREAD TYPE N 3/4" NPT M Metric M25 TYPE 26 OUTPUTS 4-20 mA, HART TYPE APPROVALS B INMETRO (Brazil) R GOST-R (Russia) W FM/CSA/ATEX/CE/IECEx TYPE CLASSIFICATION (Division/Zone) 4 Intrinsically Safe 5 Explosion Proof GTX Toxic Gas Transmitter Model Part Number Material Threads IS GTXSN26W4 GTXSM26W4 GTXSN26W5 GTXSM26W5 GTXSN26B5 GTXSM26B5 GTXSN26R4 GTXSM26R4 GTXSN26R5 GTXSM
toxics NTM Nanotechnology MOS H2S Gas Detector Model NTM Nanotechnology MOS H2S Gas Detector (Spec Sheet: 90-1195). Stainless steel, nanotechnology MOS detector that provides an accurate measurement of Hydrogen Sulfide (H2S) gas. • • • • • NTMOS H2S Gas Detector GDTB Termination Box Gas C.9 Gas C.7 U9500B Infiniti® Gas C.17 EQ2200DCU Systems C.17 CONTROLLERS UD10 Universal Display R8471x rack & panel mt controllers Q400x Series Mounting Cages Duct Mount Calibration Equipment Gas D.9 Gas C.
Toxics NTM Model Matrix MODEL DESCRIPTION NTM Nanotechnology MOS H2S Gas Detector TYPE THREAD TYPE 1A 3/4 NPT 1B Metric M25 TYPE 10 MEASUREMENT OPTIONS 0-100 ppm TYPE APPROVALS C CSA F FM W FM/CSA/ATEX/CE R Russia NTMOS Gas Sensors Model Part Number Thread ppm Approvals ISA Ship Weight NTM1A10F NTM1B10F NTM1A10C NTM1B10C NTM1A10W NTM1B10W NTM1A10R NTM1B10R 009910-001 009910-002 009910-101 009910-102 009910-003 009910-004 009910-901 009910-902 3/4 NPT M25 3/4 NPT M25 3/4 NPT M25 3/4
toxics Gas Detector Termination Box (GDTB) Gas Detector Terminaton Box (Manual: 95-8644-2.1). Recommended for installations where an approved stand-alone 4-20 mA sensor is not connected directly to a transmitter/control device. The GDTB contains a circuit board with the required connectors for proper field wiring.
Toxics Stop Plugs and Reducers Part Number Description Ship Weight 101197-001* 101197-004* 103517-001 101197-003 010816-001 010817-001 010818-001 010819-001 102804-001 102804-003 Stop Plug, 3/4” NPT, AL Stop Plug, 3/4” NPT, SS Stop Plug, M25, AL, IP66 Stop Plug, M25, SS, IP66 Stop Plug, 20 Pack, 3/4”NPT, AL Stop Plug, 20 Pack, 3/4”NPT, SS Stop Plug, 20 Pack, M25, AL,IP66 Stop Plug, 20 Pack, M25, SS,IP66 Reducer, M25 to M20, AL Reducer, M25 to M20, SS <1 lb (<0.45 kg) <1 lb (<0.45 kg) <1 lb (<0.
toxics FlexVu ® UD10 Universal Display (for Toxics) FlexVu UD10 Universal Display (Spec Sheet: 90-1200) is recommended for applications where a gas detector with digital read-out of detected gas levels are required. The FlexVu UD10 Universal Display Unit is designed for use with Det-Tronics’ toxic gas sensor/transmitters such as GT3000, NTMOS or C706x. The display unit is designed and approved as a standalone controller and performs all the functions of a gas controller. • • • • • Compliance to ISA-92.0.
Toxics FlexVu UD10 Model Matrix MODEL UD10 DESCRIPTION Universal Display Unit TYPE MATERIAL A Aluminum S Stainless Steel (316) TYPE THREAD TYPE 5M 5 Port, Metric M25 5N 5 Port, 3/4" NPT TYPE OUTPUTS 25 Relay, 4-20 mA, RS485, HART 27 Relay, 4-20 mA, HART, Foundation Fieldbus (FF) 28 EQP / DCU Emulator TYPE APPROVALS W FM/CSA/ATEX/CE/IECEx B INMETRO (Brazil) R VNIIFTRI (Russia) TYPE CLASSIFICATION (Div/Zone) 2 Ex d (Flameproof) TYPE OPTIONAL CONDITIONING BOARD N NTMOS FlexVu UD10 Universal Display – Toxics
toxics FlexVu UD10 Universal Display – Toxics (Brazil) Model Part Number Material Threads UD10A5M25B2 UD10A5N25B2 UD10S5M25B2 UD10S5N25B2 UD10A5M28B2 UD10A5N28B2 UD10S5M28B2 UD10S5N28B2 UD10A5M27B2 UD10A5N27B2 UD10S5M27B2 UD10S5N27B2 010765-081 010765-082 010765-083 010765-084 010765-085 010765-086 010765-087 010765-088 010765-089 010765-090 010765-091 010765-092 AL AL 316 SS 316 SS AL AL 316 SS 316 SS AL AL 316 SS 316 SS M25 3/4 NPT M25 3/4 NPT M25 3/4 NPT M25 3/4 NPT M25 3/4 NPT M25 3/4 NPT Relay
Toxics FlexVu UD10 Accessories Part Number 009700-001 010268-001 010204-001 102988-002 102988-026 102988-028 103726-002 103726-004 103726-011 Description Magnetic Tool Gas Inspector CD W6300G1003 Gas Inspector Connector (includes CD) Plug, 5.0mm, 6 Pos Plug, 5.0mm, 3 Pos Plug, 5.0mm, 5 Pos Plug, 3.5mm, 3-PIN Plug, 3.5mm, 5-PIN Plug, 3.5mm, 12-PIN Ship Weight <1 lb (0.45 kg) <1 lb (0.45 kg) 1 lb (0.45 kg) <1 lb (0.45 kg) <1 lb (0.45 kg) <1 lb (0.45 kg) <1 lb (0.45 kg) <1 lb (0.45 kg) <1 lb (0.
toxics FlexVu® UD20 Universal Display FlexVu UD20 Universal Display (Spec Sheet: 90-1201 - Explosion Proof Model, 90-1205 Intrinsically Safe Model) supports the GT3000 Series toxic gas detectors. Compliance to ANSI/ISA-60079-11 and ISA-92.0.
Toxics FlexVu UD20 Model Matrix MODEL UD20 DESCRIPTION Universal Display Unit TYPE MATERIAL A Aluminum S Stainless Steel (316) TYPE THREAD TYPE 5M 5 Port, Metric M25 5N 5 Port, 3/4" NPT TYPE OUTPUTS 26 Pass-Through 4-20 mA, HART TYPE APPROVALS W FM/CSA/ATEX/CE/IECEx R VNIIFTRI (Russia) TYPE CLASSIFICATION (Div/Zone) 2 Ex d (Flameproof) 4 Ex ia (Intrinsically Safe) FlexVu UD20 Universal Display (FM/CSA/ATEX/CE/IECEx) Model Part Number Material Threads Pass-Through 4-20 HART Ex d UD20A5M26W2 UD20A5N26
toxics GTD Toxic Gas Detector Assembly (GT3000 Series Toxic Gas Transmitter with FlexVu Universal Display or Separation J-Box) GTD Toxic Gas Detector Assembly incorporates a GT3000 series toxic transmitter (GTX) with a FlexVu universal display (UD) or junction box (STB). The GTS toxic gas sensor module is sold separately.
Toxics GTD Model Matrix MODEL DESCRIPTION GTD Toxic Gas Detector Assembly TYPE ASSEMBLY COMBINATION 1 GTX Transmitter and UD10 Display 2 GTX Transmitter and UD20 Display 3 GTX Transmitter and STB Termination Box TYPE HOUSING MATERIAL A Aluminum S Stainless Steel TYPE THREAD TYPE M Metric M25 N 3/4" NPT TYPE OUTPUTS 25 Relay, 4-20 mA, RS485, HART (UD10 Only) 26 4-20 mA, HART (UD20 or STB) TYPE APPROVALS W FM/CSA/ATEX/CE/IECEx TYPE CLASSIFICATION (Div/Zone) 2 Ex d (Flameproof) 4 Ex ia (IS) GTX/UD Display Ass
toxics U9500 Infiniti Transmitter U9500 Infiniti Transmitter (Spec Sheet: 90-1099). For use with a single NTMOS or C706x electrochemical toxic gas detector.
Toxics U9500 Infiniti Model Matrix MODEL U9500 DESCRIPTION Infiniti Gas Transmitter TYPE GAS B20 Hydrogen Sulfide C30 Oxygen D40 Chlorine E50 Carbon Monoxide F60 Sulfur Dioxide G60 Nitrogen Dioxide TYPE OUTPUT 01 or 02 4-20 mA 04 Relay and 4-20 mA U9500 Infiniti Toxic Transmitter and Junction Boxes (must be ordered separately) Model Part Number Used with sensor type: Relay FM/CSA/ ATEX/CE CSA/ ATEX/CE U9500B2002 U9500B2004 006265-002 006265-008 NTMOS or C7064E - H2S NTMOS or C7064E - H2S X X X
toxics Model STB Series Sensor Termination Box and Separation Kit Model STB Series Sensor Termination Box and Separation Kit includes a junction box, proper connector board, required hardware to enable proper mounting, and wiring of model GT3000 and C706x series detectors, or any 4-20 mA device.
Toxics STB Model Matrix Model STB Description Sensor Termination Box Type Compatibility 3 Model C706x electrochemical gas sensor/transmitter 7 GT3000 Toxic Gas Detectors Type Material A Aluminum S Stainless Steel (316) Type # of Ports, thread type 2M 2 PORT, M20/25 at 90 degree orientation 2N 2 PORT, 3/4" NPT at 90 degree orientation 5Y 5 PORT, M25 5N 5 PORT, 3/4" NPT TYPE APPROVALS W FM/CSA/ATEX/CE/IECEx R Russian Model STB Series Sensor Termination Boxes and Separation Kits Model
toxics GT3000 Certified Calibration Kits GT3000 Certified Calibration Kits (Manual: 95-8643) consists of a sturdy carrying case containing: Two cylinders of specified gas A 1 liter/minute regulator and pressure indicator 3-foot tube GT3000 Calibration Cup DETECTOR • • • • GTS Sensor Module ACCESSORIES DISPLAY/ CONTROLLERS TRANSMITTER/ ENCLOSURE Gas C.1 GTX Transmitter Gas C.3 UD10 Universal Display UD20 Universal Display Gas C.9 Gas C.13 Power Supplies Gas D.
Toxics GT3000 Calibration Gas Kits Part Number 010274-001 010274-002 010274-003* 010274-004 010274-005 010274-006 010274-008 010274-009 010274-010 010274-011 010274-013 010274-014 Concentration 10 ppm 25 ppm 50 ppm 5 ppm 50 ppm 250 ppm 500 ppm 20.90% 50 ppm 250 ppm 10 ppm 50 ppm Gas Hydrogen Sulfide Hydrogen Sulfide Hydrogen Sulfide Chlorine Ammonia Ammonia Hydrogen Oxygen Carbon Monoxide Carbon Monoxide Sulfur Dioxide Sulfur Dioxide Ship Weight 11.5 lb (5.23 kg) 11.5 lb (5.23 kg) 11.5 lb (5.23 kg) 11.
toxics Spare and Replacement Parts Electrochemical Sensor Cells for CGS Part Number Toxic Gas Measurement Range (ppm) FM/CSA/ ATEX/CE 005434-003 005434-004 005434-002 005932-001 005744-001 005744-002 005744-003 006400-001 005724-001 Hydrogen Sulfide Hydrogen Sulfide Hydrogen Sulfide Chlorine Carbon Monoxide Carbon Monoxide Carbon Monoxide Sulfur Dioxide Oxygen 0-20 0-50 0-100 0-10 0-100 0-500 0-1000 0-100 0-25% v/v X X X *005434-003/-004 sensors are recommended for use with C7064E housings installed
Toxics Notes 8/01/2011 52-1002-8.1 Toxics Gas C.
Displays and Controllers FlexVu ® UD10 Universal Display FlexVu UD10 Universal Display (Spec Sheet: 90-1200) is recommended for applications that require a gas detector with digital read-out of detected gas levels. The FlexVu UD10 Universal Display Unit is designed for use with Det-Tronics’ gas sensor/transmitters. The display unit is designed and approved as a stand-alone device and performs all the functions of a gas controller. • • • Compliance to ANSI/ISA-12.13.
Displays and Controllers FlexVu UD10 Model Matrix MODEL UD10 DESCRIPTION Universal Display Unit TYPE MATERIAL A Aluminum S Stainless Steel (316) TYPE THREAD TYPE 5M 5 Port, Metric M25 5N 5 Port, 3/4" NPT TYPE OUTPUTS 25 Relay, 4-20 mA, RS485, HART 27 Relay, 4-20 mA Foundation™ Fieldbus, HART 28 EQP / DCU Emulator TYPE APPROVALS W FM/CSA/ATEX/CE/IECEx B INMETRO (Brazil) R VNIIFTRI (Russia) TYPE CLASSIFICATION (Div/Zone) Ex d (Flameproof) 2 TYPE OPTIONAL CONDITIONING BOARD C CGS
Displays and Controllers FlexVu UD10 Universal Display – Brazil Model Part Number Material Threads UD10A5M25B2 UD10A5N25B2 UD10S5M25B2 UD10S5N25B2 UD10A5M28B2 UD10A5N28B2 UD10S5M28B2 UD10S5N28B2 UD10A5M27B2 UD10A5N27B2 UD10S5M27B2 UD10S5N27B2 UD10A5M25B2C UD10A5N25B2C UD10S5M25B2C UD10S5N25B2C UD10A5M28B2C UD10A5N28B2C UD10S5M28B2C UD10S5N28B2C UD10A5M27B2C UD10A5N27B2C UD10S5M27B2C UD10S5N27B2C 010765-081 010765-082 010765-083 010765-084 010765-085 010765-086 010765-087 010765-088 010765-089 010765-09
Displays and Controllers FlexVu UD10 Upgrade Kit Model Part Number Material Threads UPGRADE KIT UD10A5M25W2 UPGRADE KIT UD10A5N25W2 UPGRADE KIT UD10S5M25W2 UPGRADE KIT UD10S5N25W2 UPGRADE KIT UD10A5M28W2 UPGRADE KIT UD10A5N28W2 UPGRADE KIT UD10S5M28W2 UPGRADE KIT UD10S5N28W2 010970-001 010970-002 010970-003 010970-004 010970-005 010970-006 010970-007 010970-008 AL AL 316 SS 316 SS AL AL 316 SS 316 SS M25 3/4 NPT M25 3/4 NPT M25 3/4 NPT M25 3/4 NPT UPGRADE KIT UD10A5M25W2C UPGRADE KIT UD10A5N25W2C UP
Displays and Controllers FlexVu® UD20 Universal Display FlexVu UD20 Universal Display (Spec Sheet: 90-1201 - Explosion Proof Model, 90-1205 Intrinsically Safe Model) supports the GT3000 Series toxic gas detectors. LCD display Non-intrusive automatic calibration Non-intrusive menu system Linear 4-20 mA output with HART Intrinsically safe and explosion proof design IP66 rated DETECTOR • • • • • • GTS Sensor Module ACCESSORIES DISPLAY/ CONTROLLERS TRANSMITTER/ ENCLOSURE Gas C.1 GTX Transmitter Gas C.
Displays and Controllers FlexVu UD20 Model Matrix MODEL UD20 DESCRIPTION Universal Display Unit TYPE MATERIAL A Aluminum S Stainless Steel (316) TYPE THREAD TYPE 5M 5 Port, Metric M25 5N 5 Port, 3/4" NPT TYPE OUTPUTS 26 Pass-Through 4-20 mA, HART TYPE APPROVALS W FM/CSA/ATEX/CE/IECEx R VNIIFTRI (Russia) TYPE CLASSIFICATION (Div/Zone) 2 Ex d (Flameproof) 4 Ex ia (Intrinsically Safe) FlexVu UD20 Universal Display (FM/CSA/ATEX/CE/IECEx) Model Part Number Material Threads Pass-Through 4-20 HART Ex d UD2
Displays and Controllers R8471 Series Single Channel Rack-Mounted Gas Controllers Features include: • Approved as a stand-alone combustible gas and low concentration toxic controller, when using the relay contacts Performance certified to ATEX EN60079-29 Analog 4-20 mA signal input receiver Digital and bar graph displays indicate detected gas level Individual low, high, auxiliary, and fault alarm outputs are field programmable Standard model offers open collector outputs only Premium model offers 4-20 mA o
Displays and Controllers R8471 Single Channel Rack Mounted Gas Controllers for use with Q4004 mounting cages (4U height) Model Part Number Gas Detector Compatibility R8471A1002 R8471A1004 R8471B2002 R8471B2004 R8471B2006 R8471B2008 R8471B2010 R8471B2012 R8471C3006 R8471C3008 R8471D6002 R8471D6004 R8471E5002 R8471E5004 R8471E5102 R8471E5104 R8471E5506 R8471E5508 R8471F6002 R8471F6004 R8471H1002 R8471H1004 005479-001 005479-002 005479-003 005479-004 005479-031 005479-032 005479-029 005479-030 005479-025 0
Displays and Controllers Mounting Cages: Q4003 and Q4004 Q4004 Universal Mounting Cage for use with 4U-height (7”) R8471 gas controllers. Also supports R74xx and R60xx flame detection cards. Same size as previous Q4001 rack used with R73xx controllers. Combustible or Toxic Gas Detector with analog 4-20 mA output UD10 Universal Display R8471x rack & panel mt controllers Eagle Quantum Premier® Gas D.1 Gas D.7 Systems B.
Displays and Controllers R8471 Mounting Cages Model Part Number Capacity (max # of R8471 controllers) Height Config Height Ship Weight Q4004A2019 Q4004E2027 Q4004B2011 Q4004C2009 Q4004D2007 Q4004A2050 4U Blank Plate 005269-001 005269-002 005269-003 005269-004 005269-005 005269-006 005496-001 16 12 8 6 4 2 covers 1 slot width 4U 4U 4U 4U 4U 4U 4U 7.0 in 7.0 in 7.0 in 7.0 in 7.0 in 7.0 in 7.0 in 9.3 lb (4.2 kg) 7.6 lb (3.5 kg) 5.9 lb (2.7 kg) 5.1 lb (2.3 kg) 4.2 lb (1.9 kg) 3.1 lb (1.4 kg) 0.
Displays and Controllers Model GP16XX Gas Panel Model GP16XX Gas Panel (Spec Sheet: 90-1210) is an economical system package, designed for selected gas detection applications. • • • • • • • • • System approval to ANSI/ISA12 and 92, FM 3610-6, CSA 22.2, EN60079-29-1 and IEC6079-29-1.
Displays and Controllers GP16XX Configuration Worksheet DETECTOR ELECTRONICS CORPORATION 6901 West 110th Street Minneapolis, MN 55438 MODEL GP16XX GAS PANEL CONFIGURATION WORKSHEET Date: Customer: PO#: HARDWARE: Maximum number of field devices is 16 (i.e.
Displays and Controllers Power Supplies 000507-005 and 000507-006 24 Vdc Power Supplies (Spec Sheet: 90-1035) Ideally suited for Q1020 Wall Mount enclosures or other enclosures that contain Det-Tronics’ gas detection equipment.
Displays and Controllers Notes 8/01/2011 52-1002-8.1 Displays and Controllers Gas D.
Table of contents Systems Eagle Quantum Premier ® System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Systems A.1 Eagle Quantum Premier Controller • EQ30XX . . . . . . . . . . . . . . . . . . . . . . . . . . . . Systems B.1 EQ3001 Controller Model Matrix. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Table of contents Systems CONTINUED... FlexVu UD10 Universal Display. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Systems C.13 FlexVu UD10 Model Matrix . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . FlexVu UD10 Universal Display (FM/CSA/ATEX/CE/IECEx). . . . . . . . . . . . . . . .
Table of contents SYSTEMS CONTINUED... SIL 2 Certified Fire and Gas Detection System . . . . . . . . . . . . . . . . . . . . . . . . . . . Systems D.1 EQ3001 Controller – SIL. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . EQ3730 EDIO Module – SIL. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
OVERVIEW Eagle Quantum Premier ® System The Eagle Quantum Premier System (Spec Sheet 90-1150) combines “fire detection and extinguishing agent release” and “hazardous gas monitoring” in one complete package. The system is intended for use in hazardous locations and is designed to meet the requirements of approval agencies from around the world. The system is Factory Mutual approved to 6310/6320 and compliant to ANSI/ISA 12.13.1 and CSA 22.2 #154.
OVERVIEW SUPERVISED INPUT DEVICES SUPERVISED OUTPUT DEVICES Relay Module System C: Text Devices (Input) Water Flow, Pressure, etc.
OVERVIEW KEY: INPUT Supervised Inputs OUTPUT INPUT X3301 / X3302 Multispectrum IR Hydrogen Flame Detector INPUT X9800 Single Frequency IR Flame Detector INPUT X5200 UVIR Flame Detector INPUT X2200 UV Flame Detector EQ22XXIDC Initiating Device Circuit Supervised Outputs MISC Miscellaneous LON Devices EQ22XXIDCSC IDC Short Circuit INPUT INPUTC7050/ UVHT UV Flame Detector INPUT EQ22XXDCUEX Digital Communications Unit INPUT INPUT Addressable devices are wired into the LON Communications Loop EQ3
OVERVIEW Notes 8/01/2011 52-1002-8.1 Overview Systems A.
Control Room Eagle Quantum Premier Controller • EQ30XX Eagle Quantum Premier Controller EQ30XX (Spec Sheet: 90-1148) The Eagle Quantum Premier Controller is a microprocessor-based module that performs all the communication and control functions for the system. The controller can be configured in a simplex or redundant mode of operation. It includes all the required operator interface controls for a fire alarm and releasing system.
Control Room EQ30XX Controller Model Matrix MODEL DESCRIPTION EQ3001 Eagle Quantum Premier Controller - 246 Nodes EQ3016 Eagle Quantum Premier Controller - 16 Nodes TYPE MOUNTING OPTION D Din Rail P Panel TYPE COM Board 1 N None C ControlNet TYPE COM Board 2 N None S Serial Port Expansion TYPE APPROVALS T SIL/FM/CSA/ATEX/CE W FM/CSA/ATEX/CE R VNIIPO/VNIIFTRI (Russia) NOTE: Contact Customer Service when ordering replacement EQ30XX controllers for redundant systems.
Control Room EQ3001 Controller – SIL Model Part Number Mounting EQ3001PNNT EQ3001DNNT EQ3001PCNT EQ3001DCNT EQ3001PNST EQ3001DNST EQ3001PCST EQ3001DCST 007609-072 007609-073 007609-075 007609-076 007609-077 007609-078 007609-079 007609-080 Panel DIN Panel DIN Panel DIN Panel DIN ControlNet Serial Port Expansion X X SIL/FM/CSA/ Ship Weight ATEX/CE X X X X X X X X X X X X X X 5 lb (2.3 kg) 5 lb (2.3 kg) 5 lb (2.3 kg) 5 lb (2.3 kg) 5 lb (2.3 kg) 5 lb (2.3 kg) 5 lb (2.3 kg) 5 lb (2.
Control Room Notes 8/01/2011 52-1002-8.1 Control Room Systems B.
Control Room Power Supplies EQP21XXPS Power Supplies are used in pairs where the primary source of input supply is connected to one and the secondary source is connected to the other. A maximum of eight power supplies operated in parallel can be connected to each input supply. Both the primary and secondary sets must be individually capable of operating the system without the other supply. The secondary source is required to be continuously powered.
Control Room Power Supply. Six approved power supply options are available: • 10 Amp / 60HZ (EQ2110PS)* • 30 Amp / 60HZ (EQ2130PS)* • 75 Amp / 60HZ (EQ2175PS)* • 10 Amp / 50HZ (EQ2111PS)* • 30 Amp / 50HZ (EQ2131PS)* • 75 Amp / 50HZ (EQ2176PS)* Contact the factory for additional options and current certifications *Requires the use of the DEC Power Supply Monitor, detailed below.
Control Room Operator Interface Safety System Software Safety System Software (S3). The Eagle Quantum Premier uses the safety system software to provide a user friendly, fully integrated, high performance package. The software provides convenient and accurate system configuration and status information including diagnostic and trouble shooting tools. An optional embedded OPC server provides additional flexibility.
Control Room Operating Interface Safety System Software Part Number Description Ship Weight 007800-011* Safety System Software configuration/runtime package 60 node version without OPC driver, USB key. 0.5 lb (0.23 kg) 007800-012* Safety System Software configuration/runtime package 60 node version with OPC driver, USB key. 0.5 lb (0.23 kg) 007800-013* Safety System Software configuration/runtime package 250 node version without OPC driver, USB key. 0.5 lb (0.
Devices EQ3750 Addressable Smoke and Heat (ASH) Module The EQP Addressable Smoke and Heat (ASH) Module (Instruction Manual: 95-8654) is designed to expand the input and output capability of the Det-Tronics Eagle Quantum Premier® system. The ASH is an interface device designed to provide continuous and automated fire protection. It ensures system operation through continuous supervision of system inputs/outputs and Local Operating Network/Signaling Line Circuit (LON/SLC) monitoring in the controller.
Devices EQ3750 Addressable Smoke and Heat (ASH) Module MODEL DESCRIPTION EQ3750 Addressable Smoke and Heat (ASH) Module TYPE D MOUNTING OPTION DIN Rail TYPE W APPROVALS FM/CSA/ATEX/CE EQ3750 Addressable Smoke and Heat Module Model Part Number Material FM/CSA/ ATEX/CE Ship Weight EQ3750DW 010210-001 AL X 3 lb (1.
Devices EQ3730EDIO Enhanced Discrete Input/Output Module (EDIO) EQ3730EDIO Enhanced Discrete Input/Output Module (EDIO) (Spec Sheet: 90-1189) The 8 Channel EDIO Module is specially designed to expand the input and output (I/O) capability of the Det-Tronics Eagle Quantum Premier System. The unit is designed to provide continuous and automated fire/gas protection while ensuring system operation through continuous supervision of system I/O and signaling line circuit (SLC).
Devices EQ3730 EDIO Model Matrix MODEL DESCRIPTION EQ3730 8 Channel Enhanced Discrete Input/Output (EDIO) Module TYPE MOUNTING OPTION D DIN Rail P Panel TYPE APPROVAL AGENCY W FM/CSA/ATEX/CE T SIL/FM/CSA/ATEX/CE R VNIIPO/VNIIFTRI (Russia) EQ3730 EDIO Module Model Part Number Material FM/CSA/ ATEX/CE Ship Weight EQ3730PW EQ3730DW 009174-002 009174-003 AL AL X X 1 lb (0.45 kg) 2 lb (0.
Devices EQ3700DCIO Discrete Input/Output Module (DCIO) EQ3700DCIO Input/Output Module (DCIO) (Spec Sheet: 90-1149) The 8 Channel DC I/O Module is specially designed to expand the Input and Output (I/O) capability of the Det-Tronics Eagle Quantum Premier System. The unit is designed to provide continuous and automated fire/gas protection while ensuring system operation through continuous supervision of system I/O and signaling line circuit (SLC).
Devices EQ3700 DCIO Model Matrix MODEL DESCRIPTION EQ3700 8 Channel Discrete Input/Output (DCIO) Module TYPE MOUNTING OPTION D DIN Rail P Panel TYPE APPROVAL AGENCY W FM/CSA/ATEX/CE R VNIIPO/VNIIFTRI (Russia) EQ3700 DCIO Module Model Part Number Material FM/CSA/ ATEX/CE Ship Weight EQ3700PW 007371-002 AL X 1 lb (0.45 kg) EQ3700DW 007371-003 AL X 2 lb (0.90 kg) EQ3700 DCIO Module – Russia Part Number EQ3700PR 007371-902 AL X 1 lb (0.
Devices EQ3740IPM Intelligent Protection Module EQ3740IPM Intelligent Protection Module (Spec Sheet: 90-1184). The IPM is designed to provide continuous and automated local area fire protection, while monitoring system operation through continuous supervision of its inputs/outputs (I/O) and Local Operating Network/Signaling Line Circuit (LON/SLC) connection to the EQP controller.
Devices EQ3740 IPM Model Matrix MODEL DESCRIPTION EQ3740 Intelligent Protection Module (IPM) TYPE MOUNTING OPTION D DIN Rail P Panel TYPE W APPROVAL AGENCY FM/CSA/ATEX/CE EQ3740 Intelligent Protection Module Model Part Number Material FM/CSA/ ATEX/CE Ship Weight EQ3740PW 008055-002 AL X 1 lb (0.45 kg) EQ3740DW 008055-003 AL X 2 lb (0.90 kg) Notes 8/01/2011 52-1002-8.1 Devices Systems C.
Devices EQ3710AIM Analog Input Module EQ3710AIM Analog Input Module (Spec Sheet: 90-1183). The 8 Channel Analog Input Module expands the input capability of the Det-Tronics Eagle Quantum Premier System. The unit provides a means of connecting devices with a 4-20 mA output signal to the Eagle Quantum Premier System. Each channel is fully configurable to provide device and alarm information.
Devices EQ3710 Analog Input Model Matrix MODEL DESCRIPTION EQ3710 8 Channel Analog Input (AI) Module TYPE MOUNTING OPTION D DIN Rail P Panel TYPE APPROVAL AGENCY W FM/CSA/ATEX/CE R VNIIPO/VNIIFTRI (Russia) EQ3710 Analog Input Module Model Part Number Material FM/CSA/ ATEX/CE Ship Weight EQ3710DW 007918-003 AL X 2 lb (0.90 kg) EQ3710PW 007918-002 AL X 1 lb (0.
Devices EQ3720RM Relay Module EQ3720RM Relay Module (Spec Sheet: 90-1181) The 8 Channel Relay Module is specially designed to expand the output capability of the Det-Tronics Eagle Quantum Premier System. The Relay Module provides eight channels of relay output points that are programmed for unsupervised operation. The output relays are rated up to 2 amps per channel at 30 Vdc maximum or 0.5 amps per channel at 120 Vac. • • • • Class 1 Div.
Devices EQ3720 Relay Model Matrix MODEL DESCRIPTION EQ3720 8 Channel Relay Module (RM) TYPE MOUNTING OPTION D DIN Rail P Panel TYPE APPROVAL AGENCY W FM/CSA/ATEX/CE R VNIIPO/VNIIFTRI (Russia) EQ3720 Relay Module Model Part Number Material FM/CSA/ ATEX/CE Ship Weight EQ3720DW EQ3720PW 007792-003 007792-002 AL AL X X 2 lb (0.90 kg) 1 lb (0.
Devices FlexVu ® UD10 Universal Display FlexVu UD10 Universal Display (Spec Sheet 90-1200) is recommended for applications that require a gas detector with digital readout of detected gas levels. Its LON interface board makes the FlexVu UD10 compatible with Eagle Quantum Premier systems by digitizing the 4-20 mA analog signal from the attached sensor/transmitter and transmitting the value as a process variable over the LON to the EQP controller.
Devices FlexVu UD10 Model Matrix MODEL UD10 DESCRIPTION Universal Display Unit TYPE MATERIAL A Aluminum S Stainless Steel (316) TYPE THREAD TYPE 5M 5 Port, Metric M25 5N 5 Port, 3/4" NPT TYPE OUTPUTS 28 EQP / DCU Emulator TYPE APPROVAL W FM/CSA/ATEX/CE/IECEx B INMETRO (Brazil) R VNIIFTRI (Russia) TYPE CLASSIFICATION (Div/Zone) 2 Ex d (Flameproof) TYPE OPTIONAL CONDITIONING BOARD C CGS FlexVu UD10 Universal Display (FM/CSA/ATEX/CE/IECEx) Model Part Number Material Threads UD10A5M28W2 UD10A5N28W2 UD10S5
Devices FlexVu UD10 Spare Module Part Number* 010535-001 Description UD10 Display Module Output EQP/DCU Ship Weight 1 lb (0.45 kg) *Check with the factory for product availability. FlexVu UD10 Accessories Part Number 009700-001 010268-001 010204-001 102988-002 102988-026 102988-028 103726-002 103726-004 103726-011 Description Magnetic Tool Gas Inspector CD W6300G1003 Gas Inspector Connector (includes CD) Plug, 5.0mm, 6 Pos Plug, 5.0mm, 3 Pos Plug, 5.0mm, 5 Pos Plug, 3.5mm, 3-PIN Plug, 3.
Devices Notes 8/01/2011 52-1002-8.1 Devices Systems C.
Devices EQ2200DCU Series Digital Communication Unit EQ2200DCU Series Digital Communication Unit (Spec Sheet: 90-1118) is approved for use with a variety of Det-Tronics’ sensors including PointWatch IR gas detector and hydrogen sulfide (H2S) electrochemical sensor (C706x Series). It will also accept any sensor/transmitter with a linear 4-20 mA output signal and allows for one person non-intrusive calibration. The DCU digitizes the analog signal and transmits the value to the controller.
Devices Digital Communication Unit Model Part Number Description Material Thread Ports FM/CSA/ ATEX/CE Ship Weight EQ2207DCU EQ2217DCU EQ2253DCU EQ2263DCU EQ22EMDCU 006607-005 006607-011 006607-017 006607-019 000506-005 DCU Assy., Std DCU Assy., Std DCU Assy., Std DCU Assy., Std Full Elect. Module Assy - Panel Mount AL SS AL SS M25/M20 M25/M20 3/4 NPT 3/4 NPT 5 5 5 5 X X X X 6 lb (2.7 kg) 10 lb (4.5 kg) 6 lb (2.7 kg) 10 lb (4.5 kg) 3 lb (1.
Devices EQ2200DCUEX Series Digital Communication Unit EQ2200DCUEX Series Digital Communication Unit (Spec Sheet: 90-1118) is a digital communication unit for catalytic combustible gas sensors (CGS). The DCUEX digitizes the analog signal and transmits the value to the controller. Compliance to ANSI/ISA-12.13.01 and CSA 22.
Devices Digital Communication Unit – Combustible Sensor Only Model Part Number Description Material Thread Ports FM/CSA/ ATEX/CE Ship Weight EQ2207DCUEX EQ2217DCUEX EQ2253DCUEX EQ2263DCUEX EQ22EMDCUEX 006607-006 006607-012 006607-018 006607-020 000506-006 102740-002 DCUEX Assy., Std DCUEX Assy., Std DCUEX Assy., Std DCUEX Assy., Std Full Elect. Module Assy–Panel Mount Calibration magnet AL SS AL SS M25/M20 M25/M20 3/4 NPT 3/4 NPT 5 5 5 5 X X X X 6 lb (2.7 kg) 10 lb (4.5 kg) 6 lb (2.
Devices EQ2200UVHT and C7050 Detector EQ2200UVHT (Manual: 95-8570) combined with the C7050 Detector (Manual: 95-8214) on an EQP (or as a replacement on an older EQ system) provides fast, reliable flame detection in a wide variety of applications. The detector has the Automatic Optical Integrity (oi) feature, providing a continuous check of detector optical surfaces, detector sensitivity, and electronic circuitry of the detector/controller system.
Devices C7050B Model Matrix MODEL C7050B DESCRIPTION Controller Based UV Flame Detector TYPE MATERIAL A Aluminum S Stainless Steel (316) TYPE ENTRY 6 1 Port TYPE THREAD TYPE E 1/2” NPT F M20 TYPE OUTPUTS 4 Pulse (Standard) TYPE TUBE MODULE OPTION E DE1888K3 (High Temperature for UVHT) TYPE OPTIONS 1S Normal Operating Temperature 75°C 1H High Operating Temperature 125°C TYPE APPROVAL TYPE 1 Explosion Proof TYPE APPROVALS E ATEX/CE A FM/CSA C7050B Ultraviolet Flame Detectors Model Part Number Encl Materia
Devices EQ2200IDC Series Initiating Device Circuit (IDC) EQ2200IDC Series Initiating Device Circuit (IDC) (Spec Sheet: 90-1121) consists of a terminal wiring board and a communication module, mounted inside an explosion-proof, water-tight enclosure on a plate for mounting in an enclosure. The IDC accepts two dry contact inputs for use with devices such as relays, pushbuttons, and key switches.
Devices Initiating Device Circuit Assembly Model Part Number Material EQ2253IDC EQ2263IDC EQ2207IDC EQ2217IDC End-of-line Resistor EQ2207IDCSC EQ2217IDCSC 006608-009 006608-010 006608-013 006608-016 000106-108 007257-001 007257-002 AL SS AL SS Enclosure Thread J-Box 3/4” NPT J-Box 3/4” NPT J-Box M25/M20 J-Box M25/M20 10Kohm - 2 required AL J-Box M25/M20 SS J-Box M25/M20 Ports FM/CSA/ ATEX/CE 5 5 5 5 X X X X ATEX/CE Only Ship Weight X X 6 lb (2.7 kg) 10 lb (4.5 kg) 6 lb (2.7 kg) 10 lb (4.
Devices EQ2500SAM Series Signal Audible Module EQ2500SAM Series Signal Audible Module (Spec Sheet: 90-1129) provides two indicating circuits for controlling UL Listed 24 Vdc polarized audible/visual indicating appliances. The SAM is located on the system LON and is controlled by programmable logic in the Eagle Quantum Premier Controller. Each output circuit is independently programmable to allow annunciation of separate events.
Devices Signal Audible Module Model Part Number EQ2553SAM EQ2507SAM EQ2563SAM EQ2517SAM EQ25EMSAM EQ25EMSAM6 EQ25EMSAM4 006738-009 006738-013 006738-010 006738-016 000506-007 000505-003 000505-015 Material Thread Ports AL 3/4” NPT 5 AL M25/M20 5 SS 3/4” NPT 5 SS M25/M20 5 FULL Electronic Module ASSY–Panel Mount 3 electronics Modules in Ex d cabinet 2 electronics Modules in Ex d cabinet FM/CSA/ ATEX/CE FM/CSA Only X X X X X X X Ship Weight 6 lb (2.7 kg) 6 lb (2.7 kg) 10 lb (4.5 kg) 10 lb (4.
Devices EQ2500ARM Series Agent Release Module EQ2500ARM Series Agent Release Module (Spec Sheet: 90-1128) provides agent release capability for the Eagle Quantum System. The ARM is located on the LON and is controlled by programmable logic in the Eagle Quantum Premier Controller. The ARM can be programmed for “Single,” “Cross” or “Counting” Zone Style initiation. Optional time delay, abort, and manual release sequences allow the output to be programmed for use in unique applications.
Devices Agent Release Module Model Part Number EQ2553ARM EQ2563ARM EQ2507ARM EQ2517ARM EQ25EMARM 006733-009 006733-010 006733-013 006733-016 000506-009 Material Thread Ports AL 3/4” NPT 5 SS 3/4” NPT 5 AL M25/M20 5 SS M25/M20 5 Full Electronic Module Assy–Panel Mount FM/CSA/ ATEX/CE FM/CSA Only Ship Weight X 6 lb (2.7 kg) 10 lb (4.5 kg) 6 lb (2.7 kg) 10 lb (4.5 kg) 3 lb (1.
Devices EQ2400NE Series Network Extender EQ2400NE Series Network Extender (Spec Sheet: 90-1132) expands the capabilities of the Eagle Quantum Premier system by allowing additional nodes as well as additional wiring to be added to the LON communication loop. Without a network extender, the communication network is limited to 60 nodes on a 2,000 meter loop. Each network extender increases the capacity of the loop by 40 nodes and an additional 2,000 meters of wiring.
Devices Notes 8/01/2011 52-1002-8.1 Devices Systems C.
Devices Conventional Heat Detector for Hazardous Areas (non-addressable) Heat Detectors Part Number Ship Weight Description 000120-001 Heat Detector, 140°F, Rate Compensation Type, NO Contacts, Stainless Steel Head, UL listed 0.5 lb (0.23 kg) 000120-002 Heat Detector, 160°F, Rate Compensation Type, NO Contacts, Stainless Steel Head, UL listed 0.5 lb (0.23 kg) 000120-003 Heat Detector, 190°F, Rate Compensation Type, NO Contacts, Stainless Steel Head, UL listed 0.5 lb (0.
Devices Smoke and Heat Detectors for Unclassified Areas (non-addressable) Heat Detectors Part Number Description Ship Weight 000119-066 Smoke Detector, ionization type, dual chamber, general purpose, cULus/ FM/CSFM/MEA 2.20 lbs (1 kg) 000119-067 Smoke Detector, photoelectric type, general purpose, cULus/FM/CSFM/ MEA 2.20 lbs (1 kg) 000120-149 Heat Detector, 135°F (57°C), electronic, fixed type with 15°F (8°C) rate-ofrise, general purpose, cULus/FM/CSFM/MEA 2.
Devices Manual Call Stations (non-addressable) Class 1, Division 1 Description Ship Weight 000115-195 Manual Pull Station, push button with lift flap (dual action), SPST contact, surface mount, alloy housing painted red, key for reset, 1/2” NPT bottom, includes “FIREPUSH BUTTON” label, Class 1, Division 1, Groups C-D, NEMA 4X, UL 5.5 lbs (2.
Devices Horns (non-addressable) Class 1, Division 1 Description Ship Weight 000122-144 Horn, 27 Tones, marine grade alloy, Up to 100+/-3dB, UL Class 1, Division 1, Groups C & D, NEMA 4x, Voltage: 24VDC, Cable Entries: 1x3/4” NPT LHS, 1x3/4” NPT RHS, Duty Label: None, Tag Label: None, Other Features: None, Finish: Red Finish 12.3 lbs (5.
Devices Strobes (non-addressable) Class 1, Division 1 Part Number Description Ship Weight 000121-121 Xenon Strobe (5 Joule), NEMA 4X & 6, Alloy, UL Class 1, Division 1, Groups C & D, 24 Vdc, Red lens with no guard, 1/2” entries, No duty or Tag labels, , Red finish 4.5 lbs (2 kg) 000121-116 Xenon Strobe 21 Joule, NEMA 4X & 6, UL Class 1, Division 1, Groups C & D, 24 Vdc, 3/4” NPT Entry, 60 flash per minute, Clear Lens with no lens guard, no duty or tag label, Alloy material, Red finish 14.5 lbs (6.
Devices Strobes (non-addressable) Continued... General Purpose Part Number 000121-073 000121-115 000505-005 000121-038 102778-003 102778-004 102778-005 Description Ship Weight Strobe, NEMA 4X, Xenon type, 2.2 Joule, 1/2” pipe mount, 24 Vdc, red lens, UL/ULc/CSA, non-polarized Strobe, NEMA 4X, Xenon type, 2.
Devices Model GP16XX Gas Panel Model GP16XX Gas Panel (Spec Sheet: 90-1210) is an economical system package, designed for selected gas detection applications. • • • • • • • • • System approval to ANSI/ISA12 and 92, FM 3610-6, CSA 22.2, EN60079-29-1 and IEC6079-29-1. Utilizes Eagle Quantum Premier (EQP) 16 gas detection points available Flexible device communication protocol (LON and/or 4-20 mA) User friendly HMI touch screen User configurable User defined alarm set-points Sounder on panel 24.0in (60.
Devices GP16XX Configuration Worksheet DETECTOR ELECTRONICS CORPORATION 6901 West 110th Street Minneapolis, MN 55438 MODEL GP16XX GAS PANEL CONFIGURATION WORKSHEET Date: Customer: PO#: HARDWARE: Maximum number of field devices is 16 (i.e.
SIL 2 Certified system SIL 2 Certified Fire and Gas Detection System Det-Tronics has the capability to offer a third-party approved SIL 2 rated fire and gas detection system fully exida certified to IEC61508. EQ3001 Eagle Quantum Premier Controllers share a common hardware and software platform with standard EQP Controllers. The SIL rated version of the Controller conducts additional diagnostic checks and annunciates additional fault conditions.
SIL 2 Certified system EQ3001 Controller – SIL Model Part Number Mounting EQ3001PNNT EQ3001DNNT EQ3001PCNT EQ3001DCNT EQ3001PNST EQ3001DNST EQ3001PCST EQ3001DCST 007609-072 007609-073 007609-075 007609-076 007609-077 007609-078 007609-079 007609-080 Panel DIN Panel DIN Panel DIN Panel DIN Serial Port Expansion ControlNet X X SIL/FM/CSA/ Ship Weight ATEX/CE X X X X X X X X X X X X X X 5 lb (2.3 kg) 5 lb (2.3 kg) 5 lb (2.3 kg) 5 lb (2.3 kg) 5 lb (2.3 kg) 5 lb (2.3 kg) 5 lb (2.3 kg) 5 lb (2.
Table of contents REFERENCES Abbreviations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . References A.1 Product Life Cycle Definitions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . References A.4 Ordering Information. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
References Abbreviations References A.
references Hz GFM ib IEC ID IDC IDCGF Ind IP IR IS ISA J-box kg lb LCD LED LFL-m LON LOS LPM m mA MIR MOS mm mt mtg N/A N/C NE NEC NEMA NFPA No. N.C. NPT N.O.
References PIRTB R Repl RFI RH rly(s) RM RTC RTU RUS Rx S3 SAM SCADA sec sep SIL sgl SS STAR surv Tx TAR TDSA temp Ω UCR UEL UL ULC USB UV UVIR Vac Vdc VDS Vol w/ w/o References A.
references Product Life Cycle Definitions Active: An active product is one that is being actively promoted, with new versions being released. These products are manufactured on a regular basis and are promoted as the latest technology from Det-Tronics. Retired Product Status (RPS): An RPS product will continue to be manufactured for a maximum of five years after being given this status. No further development work will be done, or new certifications pursued, on RPS products.
References Ordering Information Ordering Information If unit required is not listed, it may be possible to order a special model that better fits the requirements. The manufacturer reserves the right to offer a particular model. Consult factory for pricing and availability. Detector Electronics Corporation 6901 West 110th Street Minneapolis, Minnesota 55438 USA The manufacturer reserves the right to make substitutions or changes to products without notice. All prices are in U.S. Dollars. Prices are F.O.B.
references General Terms and Conditions for Sales Contract (Rev. 15 June 17, 2011) All sales by Detector Electronics Corporation (hereinafter called “Det-Tronics”) of equipment offered and sold by it shall be subject to the following General Terms and Conditions which shall be deemed incorporated into all orders and offers to purchase submitted to Det-Tronics for acceptance and into all of its acceptances and contracts for sale. 1. WARRANTY.
References 4. DELIVERY. Delivery shall be FCA Factory Bloomington, Minnesota, unless otherwise agreed and indicated on our order acknowledgement. Shipping dates are approximate and are based upon current and anticipated manufacturing capabilities and upon receipt of all necessary information from Buyer. Det-Tronics reserves the right to make delivery in installments and the contract shall be severable as to each such installment.
references 11. GENERAL PROVISIONS. Det-Tronics reserves the right to correct any stenographical or clerical errors in any of the writings issued by it. Except as otherwise set forth herein, the terms and conditions and any description on the face of the acknowledgement constitute a complete and exclusive statement of the sale of the products by Det-Tronics to the Buyer. There are no other promises, conditions, understandings, representations or warranties.
References 17. EXPORT CONTROL. Buyer agrees to conduct its operations under this Contract and perform all its responsibilities in full compliance with export and other foreign trade controls under any applicable United States (U.S.) laws restricting sales or transfers to other countries or parties of commodities, software, technology, or technical data. Any other provision of this Contract to the contrary notwithstanding, Buyer agrees that no commodities, software, technology, or technical data of U.S.
references Document Charges Certificates Each Approval Certificates (i.e. FM, CSA, ATEX, CE) No Charge Certificate of Origin No Charge Certificate of Origin – Notarized $35.00 Certificate of Origin – Chamberized $180.
References Repairs and Rentals REPAIR CENTER Available only for active models listed in this price schedule. Before returning equipment for repair, contact Detector Electronics Customer Service Department to obtain a Return Material Identification (RMI) number that will be reserved for your specific return order, and referenced in all documentation. Pack the return shipment carefully to avoid damage in transit.
references NON-REPAIRABLE ITEMS 006598-001 E-Mod 006605-xxx U7602 E-Pkg 1000 Gas Controller 1100 Gas Controller 2000 Gas Controller 2100 Gas Controller 30-2056B IR Detector 400 Gas TX 405 Gas TX 410 Gas TX 415 Gas TX 500 Gas TX 700 Transmitter 704 Transmitter 710 Gas Controller 740 Gas Controller 800 Transmitter 808 Transmitter 810 Gas Controller 820 Gas Controller 880 Gas Controller 8000 Gas Controller 8100 Gas Controller Air Dilution Kit C7050 Flame Detector C7052 Flame Detector C7061C Gas Detector C7093
References REPORTS Service Report: No fee or extra charge for this. This is a report that is generated by the Repair Technician that has been assigned to repair a product that has been sent back to the factory. The report is based on the state of the defective product compared to Product Specifications of a new product. This report will consist of the following: • • • • • • The Part Number and Model Number of the product returned. The Serial Number (if applicable), Date Code and Warranty status.
references Repair Center Warranty Policy Repair Center services performed (excluding all gas sensor inspections and software-related repairs) are warranted against defects in material and workmanship for a period of two (2) months from date of shipment from Detector Electronics Corporation (Det-Tronics). This warranty applies only to the material and workmanship directly related to the specific repair services performed, and does not apply to unrelated device or component failures.
References 2012 DET-University Field Training Rate Schedule Training Deliverables All courses provide verbal presentation, practical hands-on with applicable equipment or software, course material handouts, and respective product documentation for each participant. Certificates of Completion are issued on request. Factory-Certified Technical Trainer Rates On-Site Per Day Rate (not to exceed 4 persons or 8 hours)........................................................................................$1,700.
references 2012 Field Services Rate Schedule Field Service Engineer and Project/Software Engineer Rates Field Service Engineer Project/Software Engineer Specialist On Site Per Day Rate $1,500.00 $1,700.00 $2,000.00 On Site Per Hour Rate $187.50 $212.50 $250.00 Time and One-Half $281.25 $318.75 $375.00 Double Time $375.00 $425.00 $500.00 Travel Per Hour Rate $120.00 $150.00 $175.00 1. Time and one-half applies to all work/travel performed after 8 hours per day or on Saturday. 2.