9.1 95-8616
DeVice repair anD retUrn
Prior to returning devices, contact the nearest local
Detector Electronics ofce so that a Return Material
Identification (RMI) number can be assigned. A

accompany the returned device or component to
        
.
Pack the unit properly. Always use sufficient packing
material. Where applicable, use an antistatic bag as
protection from electrostatic discharge.
NOTE
Inadequate packaging that ultimately causes
damage to the returned device during shipment
will result in a service charge to repair the damage
incurred during shipment.
Return all equipment transportation prepaid to the
factory in Minneapolis.
NOTE
It is highly recommended that a complete spare
be kept on hand for eld replacement to ensure
continuous protection.
orDerinG information
Sensor module (GTS) and transmitter (GTX) must be
ordered separately. Refer to the Transmitter and Sensor
Model Matrix on next page for ordering details.
GTS GAS SENSORS
Gas Concentration
Hydrogen Sulfide (H
2
S) 0-20 ppm
Hydrogen Sulfide (H
2
S) 0-50 ppm
Hydrogen Sulfide (H
2
S) 0-100 ppm
Oxygen (O
2
)* 0-25% V/V
Carbon Monoxide (CO) 0-100 ppm
Carbon Monoxide (CO) 0-500 ppm
Ammonia(NH
3
) 0-100, or 0-500 ppm
Sulfur Dioxide (SO
2
) 0-20 ppm
Sulfur Dioxide (SO
2
) 0-100 ppm
Chlorine (Cl
2
) 0-10 ppm
Hydrogen (H
2
) 0-1000 ppm
NitrogenDioxide(NO
2
) 0-20 ppm
*Oxygen detector for O
2
depletion (< 21% V/V) only.

 
010274-001 H
2
S / 10 ppm
010274-002 H
2
S / 25 ppm
010274- 0 0 3 H
2
S / 50 ppm
010274- 0 0 8 H
2
/ 500 ppm
010274- 0 0 9 O
2
/ 20.9%
010274-010 CO / 50 ppm
010274-011 CO / 250 ppm
010274- 0 0 5 NH
3
/ 50 ppm
010274- 0 0 6 NH
3
/ 250 ppm
010274-013 SO
2
/ 10 ppm
010274-014 SO
2
/ 50 ppm
010274- 0 0 4 Cl
2
/ 5 ppm
010274-016 NO
2
/ 10 ppm
Replacement gas cylinders for all calibration kits are
available.

 
009737-001 Calibration Cup
009700-001 Magnetic Tool
101678-007 3 Foot Tubing
107427-059 Calibration Cup O-ring
162552-001 Regulator, 1 LPM
009640-001 Replaceable Filter
ASSISTANCE
For assistance in ordering a system to meet the needs
of a specific application, contact:
Detector Electronics Corporation
6901 West 110th Street
Minneapolis, Minnesota 55438 USA
Operator: (952) 941-5665 or (800) 765-FIRE
Customer Service: (952) 946-6491
Fax: (952) 829-8750
Web site: www.det-tronics.com
E-mail: det-tronics@det-tronics.com