Specifications

58
There are three security options associated with two-way callback, one digit access,
full code access, and entering 0 to exit to keypad mode. If either of the access code
options are selected, the panel will answer the phone and play a repeated beep until a
valid code is entered or the two-way callback time expires. If neither code option is
selected, the system will be in listen-in mode when the phone is answered. Without
the "0 exits to keypad mode" options selected, the central station will not have access
to keypad mode.
Two-way Key Functions: It is not recommended to alter the telephone digit assignments for two-way voice,
however, to conform to some central stations this process may be necessary. To
reassign the assignments, place a 001 in location 0161. Each of the two-way functions
are listed along with the digit assigned. By altering the location values, each function
can be reassigned to a new key digit. Take care when altering key assignments not to
program a single digit to have multiple functions. The system will only expedite one
function per telephone digit. Two-way voice is not permitted in a UL installation.
Unattended Program Used in installations where the programming for the panel is entered into the PC
Download: software prior to the installation of the control panel. The software is left in auto
answer mode allowing the panel to call to PC, match numeric account numbers, and
download the programming file. Not supported in revision 1.00 Downloader. Use
location 9909 to set the panel account number and enter the PC phone number in 9904
(shared with automatic EML upload) . To initiate to automatic download sequence enter
9953. Unattended Program Download is not permitted in a UL installation.
Unbypass all Bypassed: This is a global option that allows all bypassed zones to become unbypassed each
time the system is disarmed. Bypass is not permitted in a UL installation.
User Code Options: The locations below each user number control the capabilities of each code. Add the
option values for each user and program the value in the appropriate location.
User Test Mode: A user Communicator test is integrated into the system to allow an end user to test the
system on a regular basis. Enter a valid user code followed by the "0" digit. The
system will speak "Enter User Test Mode." A User Communicator Test report is sent to
the central station. WHILE IN TEST MODE THE SYSTEM CEASES TO BE A SECURITY
SYSTEM. As each zone is tripped (including 24 hour zones) the system will speak the
zone description followed by "active." After 3 minutes (programmable) the panel will
automatically exit user test mode. To exit user test mode manually, enter a user code
followed by the "0" digit.
User Test Timeout: Controls the amount of time before the User Test Mode will automatically time out.
Voice Driver: With this option selected, output to the speakers will alternate between siren tones
and speech when there is a fire, burglary, emergency or panic activation. The system
will say "FIRE, FIRE, REMAIN CALM, LEAVE IMMEDIATELY", "INTRUSION
DETECTED, INTRUSION DETECTED", and "ALERT, ALERT". Not only will the type of
activation be spoken, but also the description of the zone that caused it.
Voice Only Wait Period: Amount of time the system will wait for a valid code during a secured two-way
callback or voice only session.
Wired Keypads: Allows use of the code on system keypads.
Zone Trouble Activation: This option applies only to supervised zones. With this option enabled, all trouble
conditions are treated as an activation when the system is armed.