Specifications
49
Display Open at Keypad: Used to show when specified zones are open. Typically, all internal zones (PIR's,
Smoke Detectors) are not programmed to show open status at the keypad. This
prevents constant STATUS light flashing. External zones (windows, doors) should be
programmed to show open status so the user is updated to all perimeter changes.
Zones that are programmed not to show open at the keypad are not included in the
monitor mode, unless extended monitor is used. This programming option does not
affect opening (disarming) and closing (arming) reports to the central station.
Duration Between The length of time the system pauses before saying "Entry Detected." The shortest
time
Pre-alarm Cycles: period is three seconds (000). Any value in this location is added to the default 3
seconds.
Duress: When this option is enabled, the user code will issue a silent duress code to the
central station.
Duration Between Fire, For zone trouble, transmitter tamper, or a fire zone trouble condition, a supervisory
beep
Tamper, Trouble Chirps: will be sounded at intervals determined by this time. For all activations except the
fire chirp, the tone can be silenced by checking status. Valid times are from 1 to 255
seconds. If a value of 000 is programmed, this feature is disabled. This feature must
be enabled in a UL installation.
Duration for Recognition For systems with a back up battery, the system can determine when AC power is lost.
of AC Power Loss: This location determines the time period in minutes before the system will recognize
the power loss and speak "POWER OFF." If the communicator is programmed, it will
send a report to the central station. Valid AC power loss recognition times are from 1
to 255 minutes. This feature must be enabled in a UL installation.
Echo Communicator: To listen to the communicator transmission through the inside speaker, enter 9960
while in program mode. Each communication will be heard over the inside speaker.
When testing is complete, return to programming mode and enter 9960 to turn off the
communicator monitor feature. Communicator monitor automatically turns off when
the panel is turned off or when the two-way voice circuit becomes active.
Whenever possible use the communicator monitor feature instead of a telephone butt
set. The panels phone circuit is very sensitive to loading. A good test to attempt
when experiencing communicator difficulties is to remove all connections from R1
and T1 and connect only the panel to R and T. This ensures a good phone connection
and can help isolate troublesome connections.
Echo local Phone Speech: When local (in house) phones are used as keypads, system speech is typically only
heard through the phone. With this option selected, system speech will be heard
through the inside speaker as well as the phone.
Enable Night mode: With this option selected, the system can be placed into Night mode. When the
system is armed to HOME, press the H or # key. When armed to Night mode, both
the AWAY and HOME LED's on the keypad will be lit, the entry delay doors become
instant and interior delay #2 zones are active. To exit Night mode, disarm or press
the H or # key to return to HOME mode.