Bypass Mode: To bypass individual zones, enter a valid full function code followed by the 9 digit.
The system will speak "BYPASSED MODE, ENTER ZONE NUMBER." Press a two-digit
zone number (leading zero if necessary). The current bypass state of the zone is
spoken. Pressing A toggles the bypass status (confirmed in speech). Pressing H exits
bypass mode. To unbypass all bypassed zones, enter 00 as the two-digit zone
number.
The following are system operation notes relative to bypass:
1) Bypassed zones will display open/close if programmed to do so.
2) Bypassed zones that show as open are ignored for purposes of forced arming.
3) No monitor speech or beep or alarm activation will occur for a bypassed zone.
4) Only zones that exist in the system can be bypassed. The system will issue 3-
beeps if an invalid zone number is entered.
5) Fire zones and disabled zones cannot be bypassed.
6) As a programmable option, any bypassed zone will automatically unbypass the
next time the system is disarmed. If this option is not programmed, bypassed
zones will remain bypassed until they are manually unbypassed.
Bypassing is not permitted in a UL installation.
Callback Wait Duration: The amount of time the panel will wait after a digital communication for the central
station to call during a two-way callback session.
Central Station Account: Each phone number has an account number associated with it. You may use a 3- or
4-digit account number. If Ademco Contact I.D. is being used as the reporting
format, a 4 digit account number must be used. The system allows additional
characters as follows:
Hexadecimal Digit # or H Followed By
B1
C2
D3
E4
F 5
Central Station Handshake: This location determines the amount of time the communicator will wait for a central
station receiver digital handshake.
Central Station Number: Space is provided for two 16-digit phone numbers. These numbers are programmed
as normally dialed. To enter communicator phone numbers, enter the appropriate
9000 location and enter the number. The system places the numbers in the
appropriate locations. There are characters that are available in the dialing string
that are not found on the keypad. The chart below explains how to enter additional
functions:
Dialing Feature # or H Followed By
Dial * 1
Dial # 2
Wait for second dial tone 3
3 second pause in dialing sequence 4
After the number is entered, press # or H key twice to save. Pressing the * or A key
at any time during phone number will clear all digits that have been entered.
Changing User Codes: To change user code, in keypad mode, enter a full function user code (default user 1
is 1,2,3,4), followed by the 7 digit. The system will speak "ENTER USER NUMBER."
Press the 2-digit number (01-08) for the user code you wish to change. You will then
hear "ENTER CODE (the number you selected)". The next four digits pressed will be
the new code. After the fourth digit, the system will speak "EXIT".