Ademco Contact ID Report Codes
APEX Description Code Sent to Central Station ADEMCO Description
Exterior instant
.................................
E 131 Z
............................................
Perimeter burglary
Exterior delay 1
................................
E 134 Z
............................................
Entry/exit burglary
Exterior delay 2
................................
E 134 Z
............................................
Entry/exit burglary
Interior instant
..................................
E 132 Z
............................................
Interior burglary
Interior delay 1
.................................
E 132 Z
............................................
Interior burglary
Interior delay 2
.................................
E 132 Z
............................................
Interior burglary
Fire
...................................................
E110 Z
............................................
Fire alarm
Panic
.................................................
E 120 Z
............................................
Panic alarm
Silent panic
......................................
E 122 Z
............................................
Silent
Emergency
.......................................
E 100 Z
............................................
Medical
Follower
...........................................
E 132 Z
............................................
Interior burglary
Auxiliary
...........................................
E 150 Z
............................................
24 hour nonburglary
Duress disarm
..................................
E 121 0
............................................
Duress
Duress when not armed
...................
E 121 0
............................................
Duress
Zone restore after activation
............
R 140 Z
............................................
General Alarm
Transmitter low battery
....................
E 384 Z
............................................
RF low battery
Transmitter battery restore
...............
R 384 Z
............................................
RF low battery
Zone trouble
.....................................
E 370 Z
............................................
Protection loop
Zone trouble restore
.........................
R 370 Z
............................................
Protection loop
High current trouble
.........................
E 300 91
..........................................
System trouble
High current restore
.........................
R 300 91
..........................................
System trouble
Phone line restore
............................
R 350 28
..........................................
Communication
Open (disarm)
..................................
E 401 U
...........................................
Open by user
Open after activation
.......................
E 450 U
...........................................
Exception open
Close (arm)
.......................................
R 401 U
...........................................
Close by user
Force Arm
.........................................
R 450 U
...........................................
Exception close
Control low battery
..........................
E 302 29
..........................................
Low system battery
Control battery restore
.....................
R 302 29
..........................................
Low system battery
AC fail
..............................................
E 301 29
..........................................
AC loss
AC restore
.........................................
R 301 29
..........................................
AC loss
User communicator test
...................
E 601 Z
............................................
Manual trigger test
Automatic communicator test
..........
E 602 99
..........................................
Periodic test report
Cancel
..............................................
E 406 Z
............................................
Cancel
Zone bypass
......................................
E 570 Z
............................................
Zone bypass
Zone unbypass
..................................
R 570 Z
............................................
Zone bypass
Day zone trouble
.............................
E 135 Z
............................................
Day alarm
Day zone trouble restore
.................
R 135 Z
............................................
Day alarm
Upload/download attempt
................
E 412 99
..........................................
Success - download/access
Program mode entry
.........................
E 627 99
..........................................
Program mode entry
Fail to open
......................................
E 453 99
..........................................
Failed to open
Fail to close
......................................
E 454 99
..........................................
Failed to close
Zone open
.........................................
E 371 Z
............................................
Protection Loop
Zone restore
.....................................
R 371 Z
............................................
Protection Loop
Tamper
..............................................
E 383 Z
............................................
Zone tamper
Tamper Restore
.................................
R 383 Z
............................................
Zone tamper restore
Receiver Supervision Trouble
..................
E 355 Z
............................................
Loss of radio supervision
Receiver Supervision Trouble Restore
.....
R 355 Z
............................................
Loss of radio supervision