Specifications

33
System Options - Group 4
Options - Enter Total - A description of each option is available in the Glossary Location Value
Prevent access to Program Mode when armed
............................................................................
001
Suppress Dialer during 2-way callback wait period (Not permitted in a UL installation)
........
128
Default
.........................................................................................................................
0077
.......
000
System Options - Group 5
Options - Enter Total - A description of each option is available in the Glossary Location Value
Speak auxiliary zone type
............................................................................................................
001
Speak status immediately after local phone access
....................................................................
002
Silence inside speaker in Home/Night mode (Not permitted in a UL installation)
..................
004
Speak zone description in Extended Monitor
...............................................................................
008
Disable force arming (For UL installations this option must be enabled)
..................................
064
Default
.........................................................................................................................
0078
.......
009
System Options - Group 6
Options - Enter Total - A description of each option is available in the Glossary Location Value
Speak time and date when time is requested
..............................................................................
002
Enable answer service override callback
....................................................................................
008
Default
.........................................................................................................................
0079
.......
000
Monitor Trouble Conditions
Option - A description of each option is available in the Glossary Location Value
* Monitor low battery and enable battery test (001 to enable)
...................................
0180
.......
000
* Communicator fail (001 to enable)
...........................................................................
0181
.......
001
* 000 disables (Must be enabled for UL installation)
Bypass Options
Option: Enter Total - A description of each option is available in the Glossary Location Value
Open zones automatically bypassed at force arm
...................................................................
001
Zones bypassed by force arm auto unbypassed at disarm
.......................................................
002
Unbypass all bypassed zones automatically at disarm
...............................................................
004
Default (Force Armed zones reactivated when shut)
................................................
0182
.......
000
Automatic Arming and Disarming
Options - Enter Total Location Value
Arm to AWAY
................................................................................................................................
001
Arm to HOME
...............................................................................................................................
002
Disarm
..........................................................................................................................................
008
Force arm with open zones
..........................................................................................................
016
5 day cycle (otherwise 7 day cycle)
............................................................................................
032
Default (Automatic Arm / Disarm disabled)
..............................................................
0108
.......
000
Choose the arming and disarming options and enter the total in location 0108. Use location 9993 to enter the
arm and disarm times in 24 hour format. Location 0108 requires the sum of selected options. If 001 and 002 are
programmed together, arming to AWAY will take precedence. If arm and disarm options are both selected, setting
the same time for both will never produce an automatic disarm. If 016 is not selected and there are zones open
the system will not arm. Automatic arm/disarm is not permitted in a UL installation.