System information

Troubleshooting Hardware
Book Title
3-32
The fan should begin operating and should stay on while power is applied to the system.
On some models, the DIAG LED should come on, stay on for the duration of the system’s
self-test diagnostics, and then turn off.
While booting, the console screen displays a script and system banner, which should be similar to
the following:
Cisco Catalyst Boot Firmware P/N 57-1327-02, Copyright 1995
- Initiating bootstrapping sequence.
- Boot image integrity check...Passed.
- Control transferred to boot process.
- Relocating main image to DRAM.......Done.
- Main image integrity check...succeeded.
- Control transferred to main process.
Cisco Catalyst 3000 System Software Version 1.1.1-B7, Copyright 1994,
1995.
System started on Fri. November 17, 1995 13:02:46
4 Megabytes System memory
2 Megabytes Network memory
- Initialization started
- File system initialized
- System temperature is within safe operating levels
- Warmboot initialization started
- Checking file system integrity
- LAN ports detected:
- 10Base-T : 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
- StkPort : 25
- Initializing Ports: 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 25
- Initializing system address table
- No existing diagnostic information, forcing diagnostic mode
- Starting Power Up Diagnostics test
- UART loopback test on diagnostic port...Passed
- UART loopback test on console port...Passed
- RTC memory test...Passed
- Real Time Clock test...Passed
- CPU loopback test..............Passed
- Ethernet Port loopback test...................Passed
- Ethernet Port fast transmit loopback test...................Passed
- Ethernet Port fast receive loopback test...................Passed
- Ethernet Port cross port loopback test...................Passed
- Ethernet Port broadcast test...................Passed
- Catalyst Stack Port loopback test...Passed
- Catalyst Stack Port cross port loopback test...Passed
- Catalyst Stack Port broadcast test...Passed
- CPU broadcast test...Passed
- Completed Power Up Diagnostics test
- System entering stand-alone mode
- Catalyst initiating bootp requests on one or more VLANs
- System initialization complete
- Enabling port: 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 25
Press RETURN key to activate console...
If problems occur, try to isolate the problem to a specific subsystem. The Catalyst 3000 series LAN
switches have the following subsystems:
Power subsystem—This subsystem includes the input power, AC power cable, and power supply.
Cooling subsystem—This subsystem includes the fans, which should be operating when the
system power is on.
Network interfaces and system cables subsystem—This subsystem includes all the network
interfaces and the cables that connect the equipment to the network.