System information
Troubleshooting Hardware
Book Title
3-32
• The fan should begin operating and should stay on while power is applied to the system.
• On some models, the DIAG LED should come on, stay on for the duration of the system’s
self-test diagnostics, and then turn off.
While booting, the console screen displays a script and system banner, which should be similar to
the following:
Cisco Catalyst Boot Firmware P/N 57-1327-02, Copyright 1995
- Initiating bootstrapping sequence.
- Boot image integrity check...Passed.
- Control transferred to boot process.
- Relocating main image to DRAM.......Done.
- Main image integrity check...succeeded.
- Control transferred to main process.
Cisco Catalyst 3000 System Software Version 1.1.1-B7, Copyright 1994,
1995.
System started on Fri. November 17, 1995 13:02:46
4 Megabytes System memory
2 Megabytes Network memory
- Initialization started
- File system initialized
- System temperature is within safe operating levels
- Warmboot initialization started
- Checking file system integrity
- LAN ports detected:
- 10Base-T : 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
- StkPort : 25
- Initializing Ports: 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 25
- Initializing system address table
- No existing diagnostic information, forcing diagnostic mode
- Starting Power Up Diagnostics test
- UART loopback test on diagnostic port...Passed
- UART loopback test on console port...Passed
- RTC memory test...Passed
- Real Time Clock test...Passed
- CPU loopback test..............Passed
- Ethernet Port loopback test...................Passed
- Ethernet Port fast transmit loopback test...................Passed
- Ethernet Port fast receive loopback test...................Passed
- Ethernet Port cross port loopback test...................Passed
- Ethernet Port broadcast test...................Passed
- Catalyst Stack Port loopback test...Passed
- Catalyst Stack Port cross port loopback test...Passed
- Catalyst Stack Port broadcast test...Passed
- CPU broadcast test...Passed
- Completed Power Up Diagnostics test
- System entering stand-alone mode
- Catalyst initiating bootp requests on one or more VLANs
- System initialization complete
- Enabling port: 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 25
Press RETURN key to activate console...
If problems occur, try to isolate the problem to a specific subsystem. The Catalyst 3000 series LAN
switches have the following subsystems:
• Power subsystem—This subsystem includes the input power, AC power cable, and power supply.
• Cooling subsystem—This subsystem includes the fans, which should be operating when the
system power is on.
• Network interfaces and system cables subsystem—This subsystem includes all the network
interfaces and the cables that connect the equipment to the network.