- Printed and bound in the United States of America.
- Table 1. Operating/Environmental Conditions (For indoor use).
- 2. Safety
- 2.1. Safety Information
- 2.1.1. Lockout
- 2.1.1.1. Lockout Requirements
- 2.1.1.2. Lockout Procedure
- 2.2. Provisions for Lifting and Carrying
- 2.3. Maintenance
- 2.4. Electrical Power
- 2.5. Fire
- 2.6. Equipment Lockout Requirements
- 2.6.1. Emergency Stop
- 2.7. Disconnecting Devices
- 2.7.1. Power Requirements
- 2.7.2. Disconnecting Hard-Wired Units
- 2.7.3. Disconnecting Corded Units
- 2.7.4. Disconnecting Units with Optional Disconnect Switch
- 3. Theory of Operation
- Table 2. Control Instrument Explanations.
- Review the Protocol 3 Controller Owner’s Manual for more information.
- Table 3. High Limit Instrument Explanations.
- 4. Assembly & Setup
- 5. Operation
- Table 4. Control Instrument Operating Parameters.
- Table 5. Control Instrument Set-up Parameters.
- Refer to Table 5 to change tuning parameters, if necessary.
- Table 6. High Limit instrument Setup Parameters.
- 6. Maintenance
- 6.1. Checklist
- 6.2. Lubrication
- 6.3. Cleaning and Decontamination
- 6.3.1. Cleaning the LBB Series Oven
- 6.3.2. Decontaminating the LBB Series Oven
- 6.4. Routine Tests
- 6.4.1. Test Control Instrument
- 6.4.2. Test High Limit Instrument
- 6.5. Replacement Parts
- 6.5.1. Replace the Control Instrument
- 6.5.2. Replace High Limit Instrument
- 6.5.3. Replace (Optional) Protocol 3 Controller
- 6.5.4. Replace Heater Unit
- 6.5.5. Replace Fan Motor
- 7. Troubleshooting
- Table 7. Common Technical Issues and Remedies.
- 8. Appendices
- Each oven schematic (Section 0) shows the wiring for this option.
- Each oven schematic (Section 8.4) shows the wiring for this option.
- Each oven schematic (Section 0) shows the wiring for this option.
- Table 8. LBB1-23A-1 Parts.
- Table 9. LBB1-23B-1 Parts.
- Table 10. LBB1-43A-1 Parts.
- Table 11. LBB1-43B-1 Parts.
- Table 12. LBB1-69A-1 Parts.
- Table 13. LBB1-69B-1 Parts.
- Table 14. LBB2-12-1 Parts.
- Table 15. LBB2-18-1 Parts.
- Table 16. LBB2-27-1 Parts.

LBB Series Oven Owner’s Manual OPERATION
Version 15 37
Copyright © 2012 by Despatch Industries.
All rights reserved. No part of the contents of this manual may be reproduced, copied or transmitted in any form or by any
means including graphic, electronic, or mechanical methods or photocopying, recording, or information storage and
retrieval systems without the written permission of Despatch Industries, unless for purchaser's personal use.
9. Repeat steps 7-8 for SPL .
10. Enter a value of 32.
11. Press and hold the for three (3) seconds to return to the operation mode.
a. The control now reads in degrees Fahrenheit.
b. Enter the desired setpoint.
Refer to Table 5 to change tuning parameters, if necessary.
To change from Fahrenheit to Centigrade, repeat the steps in
Section 5.4.3 using In = 5, SPH = 204, SPL = 0
5.4.4. Oven Zone Calibration
The Control instrument has been factory-tested and calibrated. Under normal operating
conditions, recalibration should not be necessary. However, to recalibrate the Control Instrument
for a specific operating condition, follow the instructions below.
Warning!
Changing program parameters alters the function of the Control.
Proceed carefully and fully understand each parameter before
changing that parameter.
1. Required Equipment: Temperature measuring device with a compatible temperature sensor.
2. Verify that bS (PV Bias) programmed in the Control instrument is set to 0. For more
information on programming parameters refer to Section 5.4.2.1.
3. Locate the temperature sensor of the temperature measuring device at the center of the
chamber.
Load the chamber with a standard amount of product to
simulate a specific operation condition.
4. Operate the oven until it reaches the desired operating temperature and the Control instrument
is regulating.
a. It will take several minutes for the unit to stabilize at the controlled temperature.
b. Allow at least 30 minutes of operation at the stabilized temperature before proceeding.
5. Subtract the average controlled temperature (value appearing on the Control instrument
display) from the actual oven temperature (value appearing on the temperature measuring
device display).
a. Note that the Control instrument and the temperature sensing device must be in the same
scale (C or F).