Manual
49
Sample Program
For the Black Box 488 to 232 converter.
10 ! Program for H-P 85 with Hpib Interface
and Black Box 488 to 232 Converter to
Talk
20 ! To a Watlow 982 Control, Copyright
Despatch March 28, 1995
30 Clear 7
40 on Timeout 7 Gosub 340
50 Set Timeout 7; 3200
60 on Key# 1 Goto 220
70 on Key# 2 Goto 160
80 on Key# 3 Goto 410
90 on Key# 4 Goto 270
100 Clear
110 Disp "K1 to Read Setpoint"
120 Disp "K2 to Set Setpoint"
130 Disp "K3 to End"
140 Disp "K4 to Analyze R$"
150 Goto 150
160 ! Set Control Setpoint
170 Disp "Enter New Set Point"
180 Input P
190 Output 710 ; "= sp1 "&val$(P)&chr$(13)
200 Print "Setpoint Changed to "; P
210 Goto 100
220 ! Read Control Setpoint
230 Output 710 ;"? sp1 "&chr$(13)
240 Enter 710 ; R$
250 Print "? Response = ";R$
260 Goto 150
270 ! String Analysis for R$
280 L=len(r$)
290 Print "# of Char in R$ = ";L
300 for I=1 to L
310 Print "Char # "; I;" of String Has Value = ";Num(r$[I])
320 next I
330 Goto 100
340 ! Print Status of Interface
350 Print "Interface Timeout"
360 for I=0 to 6
370 Status 7, I; S(i)
380 Print "Status Byte #"; I;" = ";S(i)
390 next I
400 Return
410 Disp "End"
420 End
Notes:
HPIB interface is #7.
Black Box is set for Address 10.
Watlow control is set up for
XON/XOFF.
(Prot = on) mode.