User Manual

This Manual is applicable to the    Revised April 2nd 2015 
De Sisti Super LED 4.7 
Pag 3.
4. SAFETY INSTRUCTIONS 
  Professional use: This luminaire has been designed for professional use and must be operated by 
qualified personnel only. Not for residential use. 
  Grounding: WARNING: THIS LUMINAIRE MUST BE GROUNDED 
  WARNING: Disconnect Power CORDS before 
  any maintenance work or opening the FUSE HOLDER. 
Risk of serious injury. 
  Electrical connections: IMPORTANT The cores in this mains lead are colored in accordance with the 
following code: 
 Europe 
America 
Ground  Green & yellow  Green or green & yellow 
Neutral  Blue  White 
Live  Brown  Black 
In case the colors of the cores do not correspond to the colors of the connection points on your plug, please 
proceed as follows: 
  the green or green and yellow core must be connected to the connection point marked with the letter E or 
with the symbol  or colored in green or in green - yellow; 
  the blue (or white) core must be connected to the connection point marked with the letter N or colored in 
black; 
  the brown (or black) core must be connected to the connection point marked with the letter L or colored  
in red. 
Working conditions 
  Working Position 
Lighting fixture: Max. Tilting 90° from horizontal 
  Ambient Temperature, t
a
at the place of installation and Storage 
Minimum 10°C, maximum +40°C 
  Humidity 
at the place of installation and Storage 
25-80% (not condensing) 
  Minimum distances from 
inflammable surfaces 
Top Back Sides Front 
0,1 m.  0,1 m.  0,1 m.  0,5 m. 
The luminaire should never be OPERATED close to inflammable materials. The ones indicated in the above 
table are the minimum distances recommended. Other requirements for safe use are:
A. Do not cover the apertures of the luminaire housing. They are essential for correct ventilation. 
B. Use only original accessories and spares from De Sisti Lighting. 
C. Before hanging the luminaire ensure that the suspension point (or the stand) is properly rated to accept 
the luminaire weight. 
D. In case of pole operated use, fit only a P.O. stirrup from De Sisti Lighting. 
E.  A suitable secondary safety suspension device (safety cable, chain or equivalent) must be fitted between 
the suspension point and the eyelet at the front of the body . 
WARNING : DO NOT MOUNT THE LUMINAIRE ON A NORMALLY FLAMMABLE SURFACE . 
5. INSTALLATION INSTRUCTIONS 
The following procedure should be adopted: 
Before connecting the luminaire to the electrical mains ensure that: 
A.  Earth line is present on the power socket. 
B.  The mains voltage is within the rated range of the luminaire (see technical data on the rating label) 
C.  The front safety shield is present and in good condition. 
It consists of a Fresnel lens made by borosilicate un-toughened glass, 
with a Diameter = 120 mm , thickness = 4 mm type ( 3 min ). 