7. HANDLING AND STORAGE
Precautions for safe handling
Handling
In case of rupture: Handle in accordance with good industrial hygiene and safety practice.
Avoid contact with skin, eyes or clothing. In case of insufficient ventilation, wear suitable
respiratory equipment. Use only with adequate ventilation and in closed systems. Do not
eat, drink or smoke when using this product. Take off contaminated clothing and wash
before reuse.
Conditions for safe storage, including any incompatibilities
Storage
Keep containers tightly closed in a dry, cool and well-ventilated place. Protect from
moisture. Keep out of the reach of children. Store away from other materials.
Incompatible Products
Acids. Bases. Oxidizing agent.
8. EXPOSURE CONTROLS/PERSONAL PROTECTION
Control parameters
Exposure Guidelines
The following ingredients are the only ingredients of the product above the cut-off level (or
level that contributes to the hazard classification of the mixture) which have an exposure
limit applicable in the region for which this safety data sheet is intended or other
recommended limit. At this time, the other relevant constituents have no known exposure
limits from the sources listed here
Chemical name
ACGIH TLV
OSHA PEL
NIOSH IDLH
Zinc
7440-66-6
STEL: 10 mg/m
3
respirable fraction
TWA: 2 mg/m
3
respirable fraction
TWA: 5 mg/m
3
fume
TWA: 15 mg/m
3
total dust
TWA: 5 mg/m
3
respirable fraction
IDLH: 500 mg/m
3
Ceiling: 15 mg/m
3
dust
TWA: 5 mg/m
3
dust and fume
STEL: 10 mg/m
3
fume
Nickel
7440-02-0
TWA: 1.5 mg/m
3
TWA: 1 mg/m
3
(vacated) TWA: 1 mg/m
3
IDLH: 10 mg/m
3
TWA: 0.015 mg/m
3
Lead
7439-92-1
TWA: 0.05 mg/m
3
TWA: 50 µg/m
3
TWA: 50 µg/m
3
Pb
Action Level: 30 µg/m
3
Poison;See
29 CFR 1910.1025 Action Level: 30
µg/m
3
Pb Poison;See 29 CFR
1910.1025
IDLH: 100 mg/m
3
TWA: 0.050 mg/m
3
Copper
7440-50-8
TWA: 0.2 mg/m
3
fume TWA: 1 mg/m
3
Cu dust and mist
TWA: 0.1 mg/m
3
fume
TWA: 1 mg/m
3
dust and mist
(vacated) TWA: 0.1 mg/m
3
Cu dust,
fume, mist
IDLH: 100 mg/m
3
dust, fume and mist
TWA: 1 mg/m
3
dust and mist
TWA: 0.1 mg/m
3
fume
ACGIH TLV: American Conference of Governmental Industrial Hygienists - Threshold Limit Value OSHA PEL: Occupational Safety and Health
Administration - Permissible Exposure Limits NIOSH IDLH Immediately Dangerous to Life or Health
Other Exposure Guidelines
Vacated limits revoked by the Court of Appeals decision in AFL-CIO v. OSHA, 965 F.2d
962 (11th Cir., 1992)
Appropriate engineering controls
Engineering Measures
Showers
Eyewash stations
Ventilation systems