Instructions / Assembly
INSTALLING THE FIXTURE
Do not remove ANY preinstalled CRIMP CONNECTORS ONLY LOOSE WIRES NEED TO BE CONNECTED
1. Secure the services of a qualied electrician to ensure the installation meets national and
local electrical codes.
2. Use only 120 Volt, 60 Hz power supply
3. The new xture mounts on a standard 4” junction box. Check your junction box size carefully
before attempting to mount xture. If your box is an odd size, you may need to purchase an
additional base in the proper size.
4. To begin installation, take waterproof silicone and place at small bead around the diameter
of the junction box and the back plate of the light xture. The gasket and silicone provide
a double layer of protection against water and future problems.
5. Install the 4” metal strap to your junction box with two screws.
6. Next, slide the black foam gasket over the white, black and green wires.
See diagram
7. Ensure all wire nuts are snug and properly installed.
8. Secure the xture to the junction box using the included screw through the center of
the back plate being careful not to pinch any wires. In the event your junction box is deep
in the wall obtain longer screws from a hardware store. Make sure you match the
threads correctly.
9. Adjust the oodlights to the proper angle and tighten the wing nut or locking ring, heads
can usually be tighten or untighten using your ngers
10. Adjust the Motion Sensor to the desired angle and lightly tighten into place. During SET-UP
this most likely will need adjusting again.
11. Install the bulbs.
12. Turn the power back ON by switching the circuit breaker and wall switch to the ON position.
13. The light xtures circuitry will now warm up and the RED LED will be visible.
14. Wait 90 seconds and then turn the TIME knob to TEST mode and the LED will turn o.
ENGLISH
A: Using wire nuts, connect the white
wire from xture to the white wire
from the house
B: Connect the black wire from xture
to the black wire from the house
C: Connect the Green wire from the
house junction box to the green
wire from the xture
A
B
C
White to White
Green to Green
Black to Black
Gasket
Mounting Bolt
Rubber Cap
Cross Bar
WARNING: Maintain a minimum of 1.5” (3.8cm) distance between the light bulbs and
motion sensor. Do not point the bulbs directly at the ceiling due to re hazard. Do not
let bulbs touch ceiling. Keep a minimum of 2” distance from ceiling.