Technical data
18
A100 OPERATING MANUAL
© 2002 Design, 2012 Doc. No. 12-7271-r01 (4/25/12)
NO DECO MAIN, information includes (Fig. 40) -
> Z+ (or DSAT) icon, algorithm selected.
> CF icon, if set On.
> Current Depth with FT (or M) icon.
> DTR (hr:min) with wave/clock/profile (NDC) icon.
> NX icon, if FO2 is set for nitrox, blank if Air.
> TLBG, VARI, if they apply.
• B (< 2 sec) to access ALT 1.
NO DECO ALT 1, information includes (Fig. 41) -
> Max Depth with FT (or M) and MAX icons.
> EDT (hr:min) with wave/clock icon.
• B (< 2 sec) to access ALT 2 if Nitrox, or revert to Main if Air.
• Revert to Main in 10 sec, if B is not pressed.
NO DECO ALT 2 (only if Nitrox), information includes (Fig. 42) -
> Z+ (or DSAT) icon, algorithm selected.
> O2% accumulated with icon.
> FO2 with icon, value set.
> PO2 value (x.xx ATA) with icon.
> NX icon.
• 10 sec or B (< 2 sec) to revert to Main.
SAFETY STOP MAIN, information includes (Fig. 43) -
> Z+ (or DSAT) icon, algorithm selected.
> CF icon, if set On.
> Current Depth with FT (or M) icon.
> Stop Depth with FT (or M) icon; fixed at 15 FT (4.5 M).
> Stop icon (arrows, bar) with SS icon.
> Stop Time (min:sec) with clock icon; start at 3 minutes.
> NX icon, if FO2 is set for Nitrox, blank if Air.
> TLBG, VARI, if they apply.
• B (< 2 sec) to access ALTs**.
** The SS features up to 3 ALT displays which are similar to the No Deco Main, ALT1, and ALT2 displays, respectively.
DECOMPRESSION
Decompression mode activates when theoretical No Decompression time and depth limits are exceeded.
Upon entry into Deco, the full TLBG will flash (Fig. 44) for 10 seconds. The Stop Depth digits will flash while 10 FT (3 M) below
the required Stop Depth.
> Once within 10 FT (3 M) below the required Stop Depth (stop zone), the Stop Depth digits will stop flashing.
To fulfill your decompression obligation, you should make a safe controlled Ascent to a depth slightly deeper than, or equal to,
the required Stop Depth indicated and decompress for the Stop Time indicated.
The amount of decompression credit time that you receive is dependent on Depth, with slightly less credit given the deeper you
are below the Stop Depth indicated.
You should stay slightly deeper than the required Stop Depth indicated until the next shallower Stop Depth appears. Then, you
can slowly ascend to, but not shallower than that indicated Stop Depth.
DECO STOP MAIN, information includes (Fig. 45) -
> Z+ (or DSAT) icon, algorithm selected.
> CF icon, if set On.
> Current Depth with FT (or M) icon.
> Stop Depth with FT (or M) icon.
> Stop icon (arrows, bar).
> Stop Time (hr:min) with wave/clock/profile/bar (Deco) icon.
> NX icon, if FO2 is set for Nitrox, blank if Air.
> Full TLBG (all segments).
• B (< 2 sec) to access ALT 1.
Fig. 40 - NO DECO MAIN
Fig. 41 - NO DECO ALT 1
Fig. 42 - NO DECO ALT 2
Fig. 43 - SS MAIN
Fig. 44 - DECO ENTRY
Fig. 45 - DECO STOP MAIN