Technical data

12
A100 OPERATING MANUAL
© 2002 Design, 2012 Doc. No. 12-7271-r01 (4/25/12)
SET ALM (ALARMS) LEAD-IN, information includes (Fig. 25):
> Graphics Go To and ALM with SET icon.
B (2 sec) to access Set Depth Alarm.
B (< 2 sec) to step forward to Set UTL Lead-in.
2 minutes, revert to Main if B is not pressed.
SET DEPTH ALARM, information includes (Fig. 26):
This feature is not the same as the Delayed Violation depth alarm described later.
> SET icon.
> Graphic OFF (or ON) flashing, with Depth value last set with FT (or M) and MAX icons solid.
B (< 2 sec) to step forward through the selections OFF, ON, and SET.
B (2 sec) to save the selection and access Set EDT Alarm if OFF or ON is saved, or flash the Depth digits if SET is saved.
If SET is saved and the Depth digits are flashing >>
B (< 2 sec, repeatedly) to step upward through the Set Points from 30 to 330 FT (10 to 100 M) in 10 FT (1 M)
increments.
B (2 sec) to save the Depth value (solid) and flash the graphic SET, allowing ON or OFF to be selected.
SET EDT ALARM, information includes (Fig. 27):
> SET icon.
> Graphic OFF (or ON) flashing, with Time value (hr:min) last set with wave/clock icon solid.
B (< 2 sec) to step through the selections OFF, ON, and SET.
B (2 sec) to save the selection and access Set DTR Alarm if OFF or ON is saved, or flash the Time digits if SET is saved.
If SET is saved and the Time digits are flashing >>
B (< 2 sec, repeatedly) to step upward through Set Points from 0:10 to 3:00 (hr:min) in :05 increments .
B (2 sec) to save the Time value (solid) and flash the graphic SET, allowing ON or OFF to be selected.
SET DTR ALARM, information includes (Fig. 28):
> SET icon.
> Graphic OFF (or ON) flashing, with Time value (hr:min) last set with wave/clock/profile icon solid.
B (< 2 sec) to step through the selections OFF, ON, and SET.
B (2 sec) to save the selection and revert to Set ALM if OFF or ON is saved, or flash the Time digits if SET is saved.
If SET is saved and the Time digits are flashing >>
B (< 2 sec, repeatedly) to step upward through Set Points from 0:05 to 0:20 (hr:min) in :01 increments.
B (2 sec) to save the Time value (solid) and flash the graphic SET, allowing ON or OFF to be selected.
SET UTL (UTILITIES) LEAD-IN, information includes (Fig. 29):
> Graphics Go To UTL with SET icon.
B (2 sec) to access Set Units.
B (< 2 sec) to step forward to ID - SN.
2 minutes, revert to Main if B is not pressed.
SET UNITS, information includes (Fig. 30):
> Graphic UNIT with SET icon.
> Graphic IMP with FT icon (or MET with M icon) flashing.
B (< 2 sec) to toggle between IMP (imperial) and MET (metric).
B (2 sec) to save the setting and access Set Algorithm.
SET ALGORITHM, information is to include (Fig. 31):
> Graphic ALGO with SET icon.
> Z+ (or DSAT) icon flashing.
B (< 2 sec) to toggle between Z+ and DSAT.
B (2 sec) to save the setting and access Set Conservative Factor.
When Z+ is selected, Ni-O2 related calculations are based on the Pelagic Z+ algorithm. When DSAT is selected, the
calculations are based on the standard Pelagic DSAT algorithm.
The selection locks in for 24 hours after surfacing from a dive.
Fig. 25 - SET ALARMS
LEAD-IN
Fig. 26 - SET DEPTH ALARM
Fig. 27 - SET EDT ALARM
Fig. 28 - SET DTR ALARM
Fig. 29 - SET UTILITIES
LEAD-IN
Fig. 30 - SET UNITS
Fig. 31 - SET ALGORITHM