Problem: Faucet leaks from under handle.
Cause: Adjusting ring or cap assembly has loosened.
Action:
1. Move the handle to OFF position. Remove the
index, unscrew the screw and remove the handle.
2. Tighten the adjusting ring by turning it clockwise
with a small screwdriver. Move the ball stem to the
on position and continually tighten the adjusting ring
until the leak stops draining out from around the ball
stem.
3. If the leak does not stop, loosen the adjusting ring
and tighten the entire cap assembly by turning it
clockwise. Re-tighten the adjusting ring as before.
4. Reinstall the handle.
TROUBLE SHOOTING
Problem: Faucet leaks around aerator or an improper
flow pattern.
Cause: Aerator is incorrectly fitted or is dirty.
Action:
1. Unscrew the aerator. Make sure all internal parts
are laying flat.
2. If there is debris, gently flush all parts inside.
3. Reinstall the aerator.
Many of these parts come preassembled.
This exploded diagram is to assist in trouble
shooting.
POP-UP INSTALLATION PROCEDURE
Adjusting ring
Cap
Index
Handle
Set screw
Washer
Nut
Disc spring
Disc
Mixer ball
Cam
Cam packing
Aerator
Lift rod &
Lift rod knob
Screw
Strap
Clip
Washer
Pivot nut
Pivot Rod
& Ball
Body
Washer
Nut
Gasket
Washer
Flange
Stopper
4
3
4. Place one end of the spring clip (1)
onto the end of the horizontal rod (2).
Insert the horizontal rod (2) through a
hole on the strap (3). Connect the other
end of the spring clip (1) to the
horizontal rod (2). Insert the lift rod (4)
into the strap and tighten the screw (5).
2. Apply the silicone to the underside of the flange
(2). Insert the pop-up body (1) into the drain hole
from below sink. Screw the flange (2) into the pop-up
body (1). With the pivot hole (3) facing toward faucet,
use groove joint pliers to tighten the nut (4), do not
over tighten. Do not turn the pop-up while tightening
the nut, or sealant may not seal drain. Clean excess
putty. Apply thread sealant tape to the top threads of
the tailpiece (5) in a clockwise direction, as shown
and hand tighten.
3. Install the horizontal rod (2) and
the stopper (3) as shown (4). Hand
tighten the pivot nut (1).
1. Remove the stopper (1) and the flange (2). Screw
the brass nut (3) all the way down. Push the plastic
washer (4) and the gasket (5) down. Unscrew the
pivot nut (6) from the pop-up body (7) and remove
the seal washers (8). Take off the spring clip (9)
from the horizontal rod (10). Remove the tailpiece
(11) from the pop-up body (7).
1
3
2
4
5
10
9
6
8
7
11
3
4
2
5
1
3
1
2
4
3
4
2
5
1
1
2