OWNER'S OPERATION AND INSTALLATION MANUAL UNVENTED (VENT-FREE) Gas Compact Classic Hearth Dual Burner Fireplace VDCFTNA,VDCFTPA,VDCFRPA,VDCFRNA
www.desatech.com
113133-01C22
6. With control knob pressed in, press and
release ignitor button. This will light pilot.
The pilot is attached to the front burner. If
needed, keep pressing ignitor button until
pilot lights.
Note: If pilot does not stay lit, refer to
Troubleshooting, page 29. Also, contact a
qualied service person or gas supplier for
repairs. Until repairs are made, light pilot
with match. To light pilot with match, see
Manual Lighting Procedure.
7. Keep control knob pressed in for 30 seconds
after lighting pilot. After 30 seconds, release
control knob.
Note: If pilot goes out, repeat steps 3
through 7. This replace has a safety inter-
lock system. Wait one (1) minute for system
to reset before lighting pilot again.
8. Turn control knob counterclockwise
to desired heating level. The burner
should light. Set control knob to any heat
level between HI and LO.
CAUTION: Do not try to ad-
OPERATING FIREPLACE
Continued
Figure 36 - Control Knob In The OFF
Position
Ignitor
Button
Control
Knob
Figure 37 - Natural Gas Pilot
Thermocouple
Ignitor
Electrode
Pilot Burner
Figure 38 - Propane/LP Gas Pilot
Thermocouple
Ignitor
Electrode
Pilot Burner
TO TURN OFF GAS
1. Turn control knob clockwise to the
OFF position.
2. Turn off all electric power to the appliance
(if applicable) if service is to be performed.
Turn control knob clockwise to the
PILOT position.
THERMOSTAT CONTROL
The thermostat used on this replace senses the
room temperature. At times the room may exceed
the set temperature. If so, the burner will shut off.
The burner will cycle back on when room tem-
perature drops below the set temperature.
The control knob can be set to any heat level
between HI and LO.
Note: The thermostat sensing bulb measures
the air near the replace cabinet. This may
not always agree with room temperature (de-
pending on housing construction, installation
location, room size, open air temperatures,
etc.). Frequent use of your replace will let you
determine your own comfort levels.
MANUAL LIGHTING
1. Follow steps 1 through 5 under Lighting
Instructions, beginning on page 21.
2. With control knob pressed in, strike match.
Hold match to pilot until pilot lights.
3. Keep control knob pressed in for 30 seconds
after lighting pilot. After 30 seconds, release
control knob. Now follow step 8 under
Lighting Instructions, column 1.