OWNER'S OPERATION AND INSTALLATION MANUAL UNVENTED (VENT-FREE) Gas Compact Classic Hearth Dual Burner Fireplace VDCFTNA,VDCFTPA,VDCFRPA,VDCFRNA

www.desatech.com
113133-01C 21
INSTALLING LOG SET AND SCREEN
1. Remove log packaging material and discard
packaging. Gently place log over burner (see
Figure 35). Do not allow log to contact ame.
If ame contacts log, soot will be created.
2. Reattach screen by placing the notches in the
screen frame over the shoulder screws and
pushing down.
INSTALLATION
Continued
Log
Shoulder
Screw
Screen
Figure 35 - Installing Log and Screen
OPERATING FIREPLACE
THERMOSTAT-CONTROLLED
MODELS
FOR YOUR SAFETY
READ BEFORE LIGHTING
WARNING: If you do not fol-
low these instructions exactly,
     
-

A. This appliance has a pilot which must be
lighted by hand. When lighting the pilot,
follow these instructions exactly.
B. BEFORE LIGHTING smell all around the
appliance area for gas. Be sure to smell next
to the oor because some gas is heavier than
air and will settle on the oor.
WHAT TO DO IF YOU SMELL GAS
Do not try to light any appliance.
Do not touch any electric switch; do not
use any phone in your building.
Immediately call your gas supplier from
a neighbor’s phone. Follow the gas
supplier’s instructions.
If you cannot reach your gas supplier, call
the re department.
C. Use only your hand to push in or turn the
gas control knob. Never use tools. If the
knob will not push in or turn by hand, don’t
try to repair it, call a qualied service tech-
nician or gas supplier. Force or attempted
repair may result in a re or explosion.
D. Do not use this appliance if any part has been
under water. Immediately call a qualified
service technician to inspect the appliance and
to replace any part of the control system and
any gas control which has been under water.
LIGHTING
INSTRUCTIONS
WARNING: You must operate
    
    
screen is installed before run-

   -
    
-

    
   

1. STOP! Read the safety information starting
in column 1.
2. Make sure equipment shutoff valve is
fully open.
3. Turn control knob clockwise to the
OFF position.
4. Wait ve (5) minutes to clear out any gas.
Then smell for gas, including near the oor.
If you smell gas, STOP! Follow “B” in the
safety information in column 1. If you don’t
smell gas, go to the next step.
5. Turn control knob counterclockwise
to the PILOT position. Press in control knob
for ve (5) seconds (see Figure 36, page 22).
Note: You may be running this replace for
the rst time after hooking up to gas sup-
ply. If so, the control knob may need to be
pressed in for 30 seconds or more. This will
allow air to bleed from the gas system.
If control knob does not pop out when
released, contact a qualied service person
or gas supplier for repairs.