Fire Pit User Manual

www.desatech.com
122274-01F 11
INSTALLATION CLEARANCES
WARNING: Maintain the
   

    -

Carefully follow the instructions below. This
will ensure safe installation.


A. Clearances from the side of the replace
cabinet to any combustible material and
wall should follow diagram in Figure 6.
Example: The face of a mantel, bookshelf,
etc. is made of combustible material and
protrudes 3
1
/
2
" from the wall. This com-
bustible material must be 4" from the side
of the replace cabinet (see Figure 4).
B. Clearances from the top of the rebox
opening to the ceiling should not be less
than 42".
C. When the rebox is installed directly on
carpeting, tile or other combustible mate-
rial, other than wood ooring, the rebox
should be installed on a metal or wood
panel extending the full width and depth
of the enclosure.
D. Clearances from the bottom of rebox to
the oor is 0".
These reboxes can be installed as free-
standing units against a wall with approved
cabinet mantels that may be available from
your retailer or supplier, or as a built-in unit.
The clearances are the same for either instal-
lation method.
INSTALLATION
Continued
Mantel Clearances for Built-In
Installation
If placing custom mantel above built-in re-
box, you must meet the minimum allowable
clearance between mantel shelf and top of
rebox opening shown in Figure 7. These are
the minimum allowable mantel clearances
for a safe installation. Use larger clearances
wherever possible to minimize the heating of
objects and materials placed on the mantel.
CAUTION: Do not allow the




    
   
    
  

   
  
   
minimum clearances shown in

Figure 7 - Minimum Mantel Clearances
for Built-In Installation
Figure 6 - Minimum Clearance for
Combustible to Wall
*Minimum 16" from Side Wall
Example
*