4. Press the POWER and LOCK buttons
togethertoturnoffthereplace
Note: Do not leave the hand-held remote in
theAUTO mode close to the replace. The
radiantheatfromthereplacewillturnoffthe
replace.Ideally,placethehand-heldremote
inthe center of the roomfacing towards the
replace.
Note: Do not hold the hand-held remotefor
a long time. Body temperature will affect its
operationintheAUTOmode.
Safety Features
Whenawayfromhomeforanextendedperiod
oftimeorasachildsafetyfeaturetoprevent
accidentalignitionofthereplace,thereceiver
ON/OFF/REMOTE switch should be in the
OFFposition.
Auto Shutoff Feature
1. Iftheaverageroomtemperatureexceeds
82°F(28°C),thehand-heldremotecontrol
willperformasafetyoverrideandshutthe
replaceoff.Thisfeatureisnotavailablein
theMANUmode.
2. Thereceivercontinuouslyreceivessignals
fromthehand-heldremotetocontrolthe
roomtemperature.Ifthehand-heldremote
ismisplaced,obstructedorforanyreason
cannottransmittothereceiver,thereceiver
willshutoffthereplaceafter8minutes.
OPERATING FIREPLACE
Continued
OPERATING OPTIONAL
GWMT1 WALL MOUNTED
THERMOSTAT
WARNING: Do not con-
Light the replace as instructed in Lighting
Instructionsonpage27.Setwallthermostatto
desiredtemperature.
This thermostat has been electronically cali-
brated at the factory and requires no adjust-
mentorleveling.
Uponinstallation,thethermostatmustbeal-
lowedto stabilize at room temperaturefora
minimumof30minutesforproperoperation.
Toturnthereplaceoff,adjustthermostatto
the lowest setting and turn the gas control knob
backtoPILOT.Thepilotwillremainlit.
IMPORTANT: To turn the pilot off, turn the
gas control knob on the heater to the OFF
position.
OPERATING OPTIONAL
Locatetheblowercontrolsbyopeningthelower
louverpanelonthereplace.Blowercontrols
are located on the left side of the switch bracket
totheleftjustinsidethelouverpanel.
TheBKmanualblowerandtheBKTthermo-
statically-controlledblowerhaveanONsetting
and an OFF setting. The blower will only run
whentheswitchisintheONposition.Inthe
OFFposition,theblowerwillnotoperate.
If you are using BKT
blowerwithoptionalthermostat(wallmounted
orremotecontrol)forthereplace,yourre-
placeandblowerwillnotturnonandoffatthe
sametime.Thereplacemayrunforseveral
minutesbeforetheblowerturnson.Afterthe
heatermodulatestothepilotposition,theblow-
er will continue to run. The blower will shut off
afterthereboxtemperaturedecreases.
The blower helps distribute heated air from
thereplace.Periodicallycheckthelouversof
thereboxandremoveanydust,dirt,orother
obstructionsthatwillhindertheowofair.
Figure 53 - Thermostat Hand-Held
Remote Control Unit HRC200
LOCK
MANU AUTO
ºC/ºF
TEMP
POWER
ROOM
TEMP
SET
TEMP
AUTO
Turns
Hand-Held
Remote On
or Off and
Allows You
to Choose
the Manual
Setting
Selects
AUTO
Mode
°C/°F Mode
Button
Locks
System to
Prevent
Accidental
Ignition
Turns
Burners
On or
Off
Increases or
Decreases
Room
Temperature
in AUTO
Mode
Digital Display Shows