DIRECT-VENT FIREPLACE OWNER'S OPERATION AND INSTALLATION MANUAL (V)T36NA, (V)T36PA

www.desatech.com
111250-01E 27
4. Push in gas control knob slightly and turn
clockwise to OFF.
5. Waitve(5)minutestoclearoutanygas.
Thensmellforgas,includingneartheoor.
Ifyousmellgas,STOP!Follow“B”inthe
safetyinformationincolumn1.Ifyoudon’t
smellgas,gotothenextstep.
6. Thepilotislocatedbythemainburnerand
should not require accessing for lighting.
7. Turn gas control knob counterclockwise
to PILOT.
8. Push in gas control knob all the way and
hold.Immediatelylightpilotbyrepeatedly
depressingpiezosparkignitoruntilaame
appears.Continuetoholdforabout1min-
uteafterpilotislit.Releasegascontrolknob
anditwillpopback.Pilotshouldremain
lit.Ifitgoesout,repeatsteps5through8.
9. Turnonallelectricpowertothereplace.
10. Turn gas control knob counterclockwise
to ON.
11. ThisvalveisequippedwithaHI/LOfea-
ture.Setreplaceinputasdesired.
12. Closelowerlouverpanel.
OPERATING FIREPLACE
FOR YOUR SAFETY

WARNING: If you do not fol-
low these instructions exactly,
     
-

A. Thisapplianceisequippedwithanignition
devicewhichautomaticallylightsthepilot.
Do not try to light by hand.
B. BEFORELIGHTINGsmellallaroundthe
applianceareaforgas.Besuretosmellnext
totheoorbecausesomegasisheavierthan
airandwillsettleontheoor.
WHATTODOIFYOUSMELLGAS
•Donottrytolightanyappliance.
Do not touch any electric switch; do not
useanyphoneinyourbuilding.
•Immediately call your gas supplier
fromaneighbor'sphone.Followthegas
supplier'sinstructions.
C. Useonlyyourhandtopushinorturnthe
gas control knob. Never use tools. If the
knob will not push in or turn by hand,
don'ttrytorepairit,callaqualiedservice
technician.Forceorattemptedrepairmay
resultinareorexplosion.
D. Donotuse thisapplianceifany parthas
been under water. Immediately call a
qualiedservicetechniciantoinspectthe
appliance and to replace any part of the
controlsystemandanygascontrolwhich
has been under water.
LIGHTING
INSTRUCTIONS



-



1. STOP! Read the safety information,
above.
2. Openlowerlouverpanel.
3. Turnoffallelectricpowertothereplace.
TO TURN OFF GAS
TO APPLIANCE
1. Openlowerlouverpanel.
2. SetselectorswitchintheOFFpositionto
preventdrainingbattery.
3. Turnoffallelectricalpowertotheappliance
ifserviceistobeperformed.
4. Push in gas control knob slightly and turn
clockwise to OFF.
5. Closelowerlouverpanel.

Youmayshutofftheburnersandkeepthepilot
lit by doing one of the following:
1. Turngascontrolknobclockwise
tothePILOTposition.
2. SetselectorswitchintheOFFposition.
O
F
F
P
I
L
O
T
L
O
I
H
O
N
Figure 50 - Control Valve
Piezo
Ignitor
Gas Control
Knob
Variable Control
Knob