OWNER'S OPERATION AND INSTALLATION MANUAL DIRECT-VENT FIREPLACE (V)T32EN-A SERIES,(V)T32Ep-Aa SERIES

www.desatech.com
116647-01B12
VENTING INSTALLATION INSTRUCTIONS
Continued
Vertical (V) Required
Vertical (V) Vertical Pipe Horizontal (H)
*43
3
/
4
" min. None 30" max.
53
3
/
4
" min. 1 ft. 48" max.
65
3
/
4
" min. 2 ft. 60" max.
77
3
/
4
" min. 3 ft. 84" max.
89
3
/
4
" min. 4 ft. 20' max.
* Ground Floor Corner Venting
Figure 15 - Horizontal Termination Conguration for Corner Installation Using One
90° Elbow
Square
Termination
Wall
Firestop
Not to Exceed
(H) Limits
As Required
for (V), See
Chart for
Pipe Section
Required
45°
Elbow
90° Elbow
90°
Elbow
Square
Termination
Wall
Firestop
45°
Elbow
Not to Exceed
(H) Limits
12" Min.
CORNER INSTALLATION
Recommended Applications:
Corner ground oor installation
Groundoor installation where pipe vents horizontally through wall (over 12" horizontal pipe)
Basement installation where one foot clearance from ground to termination is possible
SNORKEL TERMINATION INSTALLATION
Recommended Applications:
Installations requiring a vertical rise on building
exterior
Any installation using snorkel termination to
achieve one foot above ground
Snorkel
Termination
12" Min.
12" Min.
Adequate
Drainage
Snorkel
Termination
Snorkel
Termination
90° Elbow
12" Min.
Wall
Firestop
Snorkel terminations are available for installations
requiring a vertical rise on the exterior of the build-
ing. If installing snorkel termination below grade,
you must provide proper drainage to prevent water
from entering snorkel termination (see Figure 16).
Do not back ll around snorkel termination.
Figure 16 - Snorkel Termination Congurations for Below Ground Installation