User's Manual
www.desatech.com
116238-01E28
6. Waitve(5)minutestoclearoutanygas.
Thensmellforgas,includingneartheoor.
Ifyousmellgas,STOP!Follow“B”inthe
safetyinformationincolumn1.Ifyoudon't
smellgas,gotothenextstep.
7. Turntheequipmentshutoffvalvecounter-
clockwise totheONposition.Donot
force.
8. Closelowerlouverpanel.
9. Turnonallelectricpowertotheappliance.
10. TurnthewallswitchtotheONposition.
11. Visuallylocatethepilot.Theignitorshould
begintosparkandthemainburnershould
igniteonceameappearsatpilot.
•Iflightingtheapplianceforthersttime
eachseason,itmaytakeseveralattempts
beforethesupplygascanreachthepilot
andmainburners.
•Iftheappliancewillnotstaylitafterseveral
attempts,followtheinstructionsTo Turn
Off Gas To Applianceandcallyourservice
technicianorgassupplier.
TO TURN OFF GAS
TO AppLIANCE
1. Turnoffthewallswitch.
2. Turnoffallelectricpowertotheappliance
ifserviceistobeperformed.
3. Openlowerlouverpanel.
4. Remove front hearth brick and control
accesspanel.
5. Turn equipment shutoff valve clockwise
toOFF.Donotforce.
6. Closelowerlouverpanel.
OPERATING FIREPLACE
FOR YOUR SAFETY
WARNING: If you do not fol-
low these instructions exactly,
-
A. Thisappliancehasapilotwhichmustbe
lightedby hand.Whenlighting the pilot,
followtheseinstructionsexactly.
B. BEFORELIGHTINGsmellallaroundthe
applianceareaforgas.Besuretosmellnext
totheoorbecausesomegasisheavierthan
airandwillsettleontheoor.
WHATTODOIFYOUSMELLGAS
•Donottrytolightanyappliance.
•Donottouchanyelectricswitch;donot
useanyphoneinyourbuilding.
•Immediately call your gas supplier
fromaneighbor'sphone.Followthegas
supplier'sinstructions.
C. Donotuse thisapplianceifany parthas
been under water. Immediately call a
qualiedservicetechniciantoinspectthe
appliance and to replace any part of the
controlsystemandanygascontrolwhich
hasbeenunderwater.
LIGHTING
INSTRUCTIONS
-
1. STOP! Read the safety information
above.
2. Turnoffallelectricpowertothereplace.
3. TurnwallswitchtotheOFFposition.
4. Openlowerlouverpanel.
5. Turn equipment shutoff valve clockwise
totheOFFposition(seeFigure42).
Donotforce.
Figure 42 - Turning Equipment Shutoff
Valve to the OFF Position
Equipment
Shutoff Valve
Pilot Adjustment Screw
Sensing
Rod
Pilot
Burner
Ignitor
Figure 43 - Pilot