OWNER'S OPERATION AND INSTALLATION MANUAL DIRECT-VENT FIREPLACE V)KC36NE SERIES, (V)KC36PE SERIES

www.desatech.com
116238-01E 33
TROUBLESHOOTING
Continued

 
 
 

 -

 

1. Gas leak. 
   

2. Control valve defective
1. Foreign matter between
control valve and burner
2. Gas leak. 

1. Debris around burner air
mixer
2. Improper vent conguration
1. Air holes at burner inlet
blocked
2. Burner ame holes blocked
3. Improper venting or exces-
sive blockage
4. Excessive amounts of em-
bers and pan material

Gas odor even when control
knob is in OFF position
Gas odor during combustion
Glass soots
Dark residue on logs or inside
of replace
REMEDY
1. Locate and correct all leaks (see
Checking Ga s Connections,
page 23)
2. Replace control valve
1. Take apart gas tubing and remove
foreign matter
2. Locate and correct all leaks (see
Checking Ga s Connections,
page 23)
1.
Inspect the opening at the base of
the burner by removing log/grate
assembly to see that it is NOT
packed with any type of material
[see Installing Brick Liner Models
BL36DA(SA) and BL36DHA(SA),
page 25] for log/grate removal
2. Check vent configuration speci-
cation (see Venting Installation
Instructions, page 9)
1. Clean out air holes at burner inlets.
Periodically repeat as needed
2. Remove blockage
3. Have the vent system inspected, in-
cluding the termination cap. Remove
any restrictions or obstruction
4. Clear excess embers until a mini-
mum gap of 1/2" remains under the
grate