DIRECT-VENT FIREPLACE OWNER'S OPERATION AND INSTALLATION MANUAL PENINSULA MODELS (V)DVF36 TPNA-A(-HA)/TPNPA-A/TPNEA-A/TPNPEA-A SEE-THRU MODELS (V)DVF36 TSTA-A(-HA)/TSTPA-A/TSTEA-A/TSTPEA-A
www.desatech.com
56131-F26
Figure 52 - Correct Pilot Flame Pattern
1/8"
(0.3cm)
3/8" - 1/2"
(.95cm-1.3cm)
1/2"
(12.7 mm)
3/4"
(19 mm)
Edge of Burner
Top of 
Burner
Figure 53 - Correct Ignitor Location
(Side View)
bURNER FLAME 
ADjUSTMENT
The  air  shutter,  located  at  the  base  of  the  main 
burner (see  Figure  54),  has  been  factory  preset 
to the proper air-to-gas ratio which results in an 
even, clean burning ame across the burner (see 
Figure 55). If readjustment is necessary, you can 
restore the proper air-to-gas ratio by loosening the 
air shutter screw and rotating the air shutter until 
the proper ame setting is achieved (the shutter's 
normal  setting  is  fully  open.  Do  not  forget  to 
retighten the air shutter screw.
Figure 55 - Burner Flame Patterns
Figure 54 - Air Shutter Adjustment
Air Shutter
Air 
Opening
Burner
Venturi 
Tube
Burner Gas Line
CORRECT
INCORRECT
CLOSE 
SHUTTER
INCORRECT
OPEN SHUTTER
Short, Sharp, Blowing Flame
Long, Blue Flame with 
Yellow Tips
Long, Uneven, Yellow Flame
Firebox Bottom
Adjustment
Screw
Orice
-
1.  Remove top and bottom louvers and screen as-
sembly. Undo 4 latches and open glass door.
2.  Carefully  remove  the  log  set  intact  and  set 
aside (see Figure 56, page 27).
3.  Remove the 2 screws holding burner to hearth 
pan.
DECORATIVE FACING
Any  noncombustible  material  may  be  used  for 
facing (glass, tile, brick, etc.) as long as the proper 
clearances are observed (see Clearances, page 6). 
IMPORTANT: Louvered openings must not be ob-
structed, and upper and lower panels must remain 
removable for servicing. Use only heat-resistant, 
noncombustible mortar or adhesive when securing 
facing material.
Note: Combustible material, such as wood, that 
has been reproofed  is  not considered noncom-
bustible.
PILOT/ELECTRODE 
ASSEMbLy ADjUSTMENT
The pilot assembly is factory preset for the proper 
ame height. Alteration to these settings may have 
occurred during shipping and handling. If this is the 
case, some minor adjustment may be necessary and 
should be done by a qualied technician. To access 
the pilot assembly, the glass door must be opened. 
The proper settings for the thermopile height should 
be at a distance of 3/8" to 1/2" from the pilot ame 
as shown in Figure 52.
The electrode is installed at the factory for proper 
positioning. However, alterations to the position 
may have occurred due to shipping and handling. 
These settings may need adjustment and must be 
done by a qualied technician. The correct position 
and height is as shown in Figure 53.
INSTALLATION
Continued