DIRECT-VENT FIREPLACE OWNER'S OPERATION AND INSTALLATION MANUAL PENINSULA MODELS (V)DVF36 TPNA-A(-HA)/TPNPA-A/TPNEA-A/TPNPEA-A SEE-THRU MODELS (V)DVF36 TSTA-A(-HA)/TSTPA-A/TSTEA-A/TSTPEA-A
www.desatech.com
56131-F 19
VENTING INSTALLATION 
INSTRUCTIONS
Continued
Figure 32 - Vertical Rigid Venting 
Conguration With No Horizontal Run
V = 40' max.
PARTS LIST FOR DESA VENTING 
  
VKR-58  R oo f  Ven t  K it ,   G a lv a ni ze d  
  (Includes:  45°  Elbow,  7"-12"  
  Adjustable  Pipe,  Flue  Restrictor,  
  Vertical  High  Wind  Termination, 
  2'  Pipe,  4'  Pipe,  Wall  Firestop,  
  Storm  Collar,  Roof  Flashing 
  [0/12 - 6/12], 26 Screws)
VKB-58  Basement  Vent  Kit,  Galvanized  
  (Includes:  45°  Elbow,  7"-12"  
  Adjustable  Pipe,  Wall  Firestop,  
  Horizontal  Square  Termination,  
  4' Pipe, 90° Elbow, 20 Screws)
VKS-58  Snorkel  Vent  Kit,  Galvanized  
  (Includes:  45°  Elbow,  7"-12"  
  Adjustable  Pipe,  Wall  Firestop, 
  36" Snorkel Termination, 4' Pipe,  
  1' Pipe, 90° Elbow, 26 Screws)
VKG-58  Ground Floor Vent Kit, Galvanized  
  (Includes:  45°  Elbow,  7"-12"  
  Adjustable  Pipe,  Wall  Firestop,  
  Horizontal  Square  Termination,  
  16 Screws)
P58-48  48" Section Double Wall Pipe, 
  Galvanized
P58-36  36" Section Double Wall Pipe, 
  Galvanized
P58-24  24" Section Double Wall Pipe, 
  Galvanized
P58-12  12" Section Double Wall Pipe, 
  Galvanized
P58-6  6" Section Double Wall Pipe, 
  Galvanized
HIGH ALTITUDE INSTALLATION
Your  DESA  direct-vent  fireplace  has  been 
tested and approved for elevations from 0-2,000 
feet  (USA)  and  elevations  from  0-4,500  feet 
(Canada)
Fireplaces  for  High Altitude  (models  ending  in 
-HA) are  for  installation above  4,000  feet only. 
These replaces are equipped with parts specic 
for  higher  altitudes.  IMPORTANT:  These  re-
places can NOT be converted to propane/LP gas.
When installing a non-high altitude replace at an 
elevation above 2,000 feet (USA), you may need to 
decrease the input rating by changing the existing 
burner orice to a smaller size. Reduce input 4% 
for each 1,000 feet above sea level. Check with 
your  local  gas  company  for proper    orice  size 
identication. 
When  installing  this  fireplace  at  an  elevation 
above  4,500  feet  (Canada),  check  with  local 
authorities.
IMPORTANT:  For  horizontal  installations 
above 2,000 feet, it is recommened that a 12" 
extension pipe be added before starter elbow 
(see Figure 33). 
Figure 33 - Recommended 12" Extension 
for High Altitude Installation
45° Starter 
Elbow
Note: Install 
restrictor into inner 
collar of replace 
as shown.
45° Starter 
Elbow
12" 
Extension