B-VENT DECORATIVE ELECTRONIC IGNITION GAS FIREPLACE OWNER’S OPERATION AND INSTALLATION MANUAL MODELS M36E(B,H), M42E(B,H), VM36E(B,H) AND VM42E(B,H) NATURAL GAS MODELS M36EP(B,H), M42EP(B,H), VM36EP(B,H) AND VM42EP(B,H) PROPANE/LP GAS WARNING: If the information in these instructions is not followed exactly, a fire or explosion may result causing property damage, personal injury or death.
WARNING: Improper installation, adjustment, alteration, service or maintenance can cause injury or property damage. Refer to this manual for correct installation and operational procedures. For assistance or additional information consult a qualified installer, service agency or the gas supplier. NOT FOR USE WITH SOLID FUEL CHECK LOCAL CODES PRIOR TO INSTALLATION SAVE THIS BOOK This book is valuable.
SAFETY INFORMATION WARNING: This product contains and/or generates chemicals known to the State of California to cause cancer or birth defects or other reproductive harm. IMPORTANT: Read this owner’s manual carefully and completely before trying to assemble, operate or service this fireplace. Improper use of this fireplace can cause serious injury or death from burns, fire, explosions, electrical shock and carbon monoxide poisoning.
SAFETY INFORMATION Continued 11. Keep the area around your fireplace clear of combustible materials, gasoline and other flammable vapor and liquids. Do not run fireplace where these are used or stored. Do not place items such as clothing or decorations on or around fireplace. 12. Do not use this fireplace to cook food or burn paper or other objects. 13. Do not use any solid fuels (wood, coal, paper, cardboard, etc.) in this fireplace. Use only the gas type indicated on fireplace nameplate. 14.
INTRODUCTION Continued WARNING: Installation of this appliance should be done by a qualified service person well trained in the installation of such appliances. You will also need a building permit from your local Building and Safety Commissioner before installing this appliance; otherwise your insurance co. may not cover this appliance. NOTICE: This appliance is not intended to be used as a primary source of heat. CAUTION: Do not connect appliance before pressure testing gas piping.
PRODUCT SPECIFICATIONS GAS RATING - NATURAL M36E(B,H), M42E(B,H), VM36E(B,H) VM42E(B,H) Max. Input Rating: 40,000 Btu/Hr 45,000 Btu/Hr Manifold Pressure: 3.5 in. WC (.87 kPa) 3.5 in. WC (.87 kPa) Minimum Supply Pressure: 4.5 in. WC (1.12 kPa) 4.5 in. WC (1.12 kPa) Maximum Supply Pressure: 10.5 in. WC (2.66 kPa) 10.5 in. WC (2.66 kPa) # 30 # 29 Orifice Size: GAS RATING - PROPANE/LP M36P(B,H), VM36P(B,H) M42P(B,H), VM42P(B,H) Max.
PRE-INSTALLATION PREPARATION MANTEL CLEARANCES AND WALL DETAILS CLEARANCES Minimum clearances to combustibles are: • Back and Sides of Outer Surround . . . 0" min. • Drywall to Sides of Front Face (Nailing Flanges) . . . . . . . . . . . . . . 0" min. • “B” Vent Surfaces . . . . . . . . . . . . . . . . 1" min. • Ceiling to Opening . . . . . . . . . . . . . . 42" min. • Floor . . . . . . . . . . . . . . . . . . . . . . . . . . 0" min. • Perpendicular Wall . . . . . . . . . . .
PRE-INSTALLATION PREPARATION Continued FRAMING 1. Frame appliance enclosure as illustrated in Figures 7 and 8. Note: If a wall covering is used to line the enclosure, then all measurements must be from the surface of the covering. 2. Place the appliance into the framing and secure it. Note: If appliance is to be raised above floor level, a platform must be built to support the appliance. 3.
PRE-INSTALLATION PREPARATION Continued INSTALLING TRANSITION PIPE AND STARTER COLLAR The transition pipe and starter collar shown in Figure 9 are supplied with the fireplace, unattached and ready for installation. Remove the starter collar and set aside. Slide the transition pipe over the vent collar and attach with a minimum of three screws. Replace the starter collar over the transition pipe and attach using four screws located on the leg stands (five used on the model M42E).
VENTING INSTALLATION Continued Listed Vent Cap Maintain Listed Clearance Maintain Listed Clearance 12' Min. Position Firestop 45 6' Maintain Listed Clearance 12' Min. 45 12' Min.
INSTALLATION VENTING INSTALLATION Continued CHECKING FOR PROPER VENTING After completing and checking the electrical, gas and vent connections, follow the lighting instructions and allow the main burner to run for approximately 5 minutes. Hold a lighted match or cigarette near the top edge of the fireplace opening and play it along the entire length of the opening (see Figure 12). Proper venting should tend to draw the flame or smoke into the appliance.
INSTALLATION Continued 3. Activate the remote handset battery by removing the insulating tab on the back of the handset (see Figure 15). The battery is included pre-installed. 4. Once the battery is activated the unit is ready to use. 5. Replace front refractory access panel. Battery Cover 12 Volt Battery DESA recommends that a black iron gas line be routed from the gas source, through a sediment trap (shown in Figure 18) and into the appliance.
INSTALLATION EMBER AND PAN MATERIAL PLACEMENT Continued 1. Open the bag(s) of vermiculite and fill the entire burner pan until the burner tube is completely covered (see Figure 20). 2. Smooth the pan material just even with edges of the burner pan. 3. Remove the ember material from the bag and flatten small amounts into quarter size pieces and lay on top of the surface of the pan material (see Figure 21). 4.
INSTALLATION Continued Grate 0.5" Pan and Ember Material NOTICE: Do not put lava rock inside the burner pan or around the air mixer fitting. Placing lava rock inside the burner pan or blocking the openings of the propane/LP air-mixer could cause performance problems. Log 4 0.5" Burner Pan Figure 22 - Pan and Ember Material Clearances Log 2 Log 3 Notches LOG PLACEMENT FOR M36E, M36EP, VME36 AND VM36EP MODELS 1. Place small front right log (log 1) on right front of grate as shown in Figure 23. 2.
INSTALLATION Continued LOG PLACEMENT FOR M42E, M42EP, VME42 AND VM42EP MODELS 1. Place large back log (log 1) onto grate making sure notches rest over grate (see Figure 27). 2. Insert lower end of log 2A between the first two grate fingers and position the upper end into the notch on the front of log 1. See Figure 27. Place log 2B on the front right side of grate as shown in Figure 27. 3. Place log 3 into notch on top left of log 1, resting the lower end on the left two grate fingers (see Figure 28). 4.
INSTALLATION INSTALLING OPTIONAL GLASS DOOR ACCESSORY Continued COMBUSTION AIR KIT MODEL AK4 (OPTIONAL) The outside air kit may be installed on the left side of the fireplace only. The vent can be installed through any outside wall a minimum of three feet below fireplace termination cap. The handle to operate the damper door for the outside air inlet will be located inside the left “screen pocket” of the firebox (see Figure 31). Pull the handle to open or push to close.
INSTALLATION Continued 6. Repeat the process for the opposite door assembly. 7. To adjust the doors, slide them partially open. Using a screwdriver, loosen the hold-down screws in the spring clip (see Figure 34) and pivot plate. 8. Close both doors until evenly joined at the middle and note the gap at the outer edges of the face. 9. Reopen one door at a time and retighten the upper and lower hold-down screws. 10. Repeat the process until both doors are evenly joined, spaced and working freely.
OPERATING FIREPLACE FOR YOUR SAFETY READ BEFORE LIGHTING WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life. A. This appliance has a pilot which must be lighted by hand. When lighting the pilot, follow these instructions exactly. B. BEFORE LIGHTING smell all around the appliance area for gas. Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor.
OPERATING FIREPLACE INSPECTING BURNERS Continued Check pilot flame pattern and burner flame patterns often. TO TURN OFF GAS TO APPLIANCE PILOT ASSEMBLY 1. Turn off the wall switch. 2. Turn off all electric power to the appliance if service is to be performed. 3. Fully open glass doors if installed. 4. Remove front hearth brick and control access panel. 5. Turn gas control knob clockwise to “OFF”. Do not force. 6. Replace front refractory brick access panel. 7. Fully close glass doors if installed.
CLEANING AND MAINTENANCE WARNING: Installation and repair should be done by a qualified service person. The appliance should be inspected before each use and at least annually by a qualified service person. More frequent cleaning may be required due to excessive lint from carpeting, bedding material, pet hair, etc. It is imperative that the control compartments, burners and circulating air system be kept clean. WARNING: The logs can be hot. Handle only when cool.
WIRING DIAGRAM Pilot Burner ON WALL SWITCH (SUPPLIED) Pilot Gas Line OFF INCOMING MAIN GAS SUPPLY BLACK IGN WHITE GREEN GND TR PV/MV BLACK WHITE GREEN PV MANUAL DAMPER SWITCH Robertshaw MODEL SP745 IGNITION CONTROL VENT SAFETY SHUTOFF SWITCH EV1 INCOMING 120V AC (FUSE BOX OR BREAKER) TH MV ELECTRICAL RATING: 120v, 60Hz, 0.7A EV2 24V AC STEP DOWN TRANSFORMER 120V AC OPTIONAL REMOTE CONTROL GAS LINE TO BURNER 108796-01K www.desatech.
TROUBLESHOOTING Note: Before troubleshooting the system, make sure the gas shutoff valve is ON. The two most common causes of a malfunctioning gas appliance are: 1. Loose wiring connections 2. Construction debris clogging the pilot and/or gas control valve filter OBSERVED PROBLEM POSSIBLE CAUSE REMEDY Ignitor will not spark or pilot will 1. No gas supply or shutoff not light valve is OFF 2. 3. 4. 5. 6. 7. 8. Pilot will not stay lit 1.
TROUBLESHOOTING Continued WARNING: If you smell gas • Shut off gas supply. • Do not try to light any appliance. • Do not touch any electrical switch; do not use any phone in your building. • Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions. • If you cannot reach your gas supplier, call the fire department. IMPORTANT: Operating fireplace where impurities in air exist may create odors.
ILLUSTRATED PARTS BREAKDOWN MODELS M36E(B,H), M36EP(B,H), M42E(B,H), M42EP(B,H), VM36E(B,H), VM36EP(B,H), VM42E(B,H) AND VM42EP(B,H) 51 21 57 3 57 25 2 10 28 32 11 6 26 31 43 27 37 36 38 LP 35 34 30 33 34 35 NG 29 63 1 50 20 18 24 11 63 22 49 52 61 14 43 12 62 52 9 15 59/60 48 16 23 58 4 7 17 56 13 42 41 46 8 19 67 65 67 68 40 66 5 47 39 64 69 54 17 70 45 55 71 44 7 47 24 www.desatech.
PARTS LIST This list contains replaceable parts used in your heater. When ordering parts, follow the instructions listed under Replacement Parts on page 20 of this manual. KEY M36E(P)(B,H) M42E(P)(B,H) NO.
PARTS LIST This list contains replaceable parts used in your heater. When ordering parts, follow the instructions listed under Replacement Parts on page 20 of this manual. 14 12 16 13 15 KEY M36(B,H) M42(B,H) NO. VM36(B,H) VM42(B,H) DESCRIPTION 12 106658-02 107812-02 Left Refractory, Std. Brick (M36EB/ME42B) 108164-02 108169-02 Left Refractory, Herringbone (M36EH/M42EH) 106658-01 107812-01 Left Refractory, Std.
ILLUSTRATED PARTS BREAKDOWN LOGSETS FOR MODELS M36(B,H), M36P(B,H), VM36(B,H) AND VM36P(B,H) 5 4 6 3 5 4 2 3 1 KEY PART NO. NUMBER DESCRIPTION - 107999-01 Log Set 1 108724-01 Right Front 9" Split Log 1 2 901098-01 Rear Log 1 3 108720-01 Top Right Log - 11 3/4" 1 4 108721-01 Top Right Log - 16" 1 5 108722-01 Top Left Log - 13 1/2" Y-Log 1 6 108723-01 Top Left Log - 11" 1 QTY. 1 2A 2B 108796-01K www.desatech.
5 ILLUSTRATED PARTS BREAKDOWN 4 LOGSETS FOR MODELS M42(B,H), M42P(B,H), VM42(B,H) AND VM42P(B,H) 3 5 4 3 1 6 1 2A 2B 28 KEY PART NO. NUMBER DESCRIPTION - Log Set 107999-02 QTY. 1 901098-02 Rear Log 2A 108723-01 Left Front Log - 11" 1 2B 108839-01 Right Front Log - 15 / " Round 1 3 108722-01 Top Left Log - 13 1/2" Y-Log 1 4 108838-01 Inside Top Left Log - 15 3/4" Split 1 5 108721-01 Inside Top Right Log - 16" 1 6 108720-01 Top Right Log - 11 3/4" 1 1 3 4 www.
ACCESSORIES NOTICE: All accessories may not be available for all fireplace models. Purchase these firebox accessories from your local dealer. If they can not supply these accessories, call DESAʼs Sales Department at 1-866-672-6040 for information. You can also write -to the address listed on the back page of this manual. AIR KIT - AK4 BLOWER KIT Optional kit helps offset the negative pressure often existing in today's tightly constructed homes.
NOTES _____________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ___________
NOTES _____________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ___________
WARRANTY INFORMATION KEEP THIS WARRANTY Model Serial No. Date Purchased Always specify model and serial numbers when communicating with the factory. We reserve the right to amend these specifications at any time without notice. The only warranty applicable is our standard written warranty. We make no other warranty, expressed or implied.