OWNER'S OPERATION AND INSTALLATION MANUAL VENT-FREE PROPANE/LP GAS BAY FRONT FIREPLACE CF26PT

6
107187
VENT-FREE PROPANE/LP BAY FRONT FIREPLACE
CF26PT
For more information, visit www.desatech.com
INSTALLATION
Note:
Your Comfort Glow fireplace is de-
signed to be used in zero clearance installa-
tions. Wall or framing material can be placed
directly against any exterior surface of your
fireplace, except where standoff spacers are
integrally attached. If standoff spacers are
attached to your fireplace, these spacers can
be placed directly against wall or framing
materials.
Use the dimensions shown for rough open-
ings to create the easiest installation (see
Built-In Fireplace Installation, page 8).
WARNING: A qualified ser-
vice person must install fireplace.
Follow all local codes.
NOTICE: This heater is intended
for use as supplemental heat. Use
this heater along with your pri-
mary heating system. Do not in-
stall this heater as your primary
heat source. If you have a central
heating system, you may run
systems circulating blower while
using heater. This will help circu-
late the heat throughout the
house. In the event of a power
outage, you can use this heater
as your primary heat source.
Figure 3 - Ventilation Air from Outdoors Shown with Optional Mantel
Outlet
Air
Ventilated
Attic
Outlet
Air
Inlet
Air
Inlet Air
Ventilated
Crawl Space
To
Crawl
Space
To Attic
AIR FOR
COMBUSTION AND
VENTILATION
Continued
Figure 2 - Ventilation Air from Inside Building Shown with Optional Mantel
VENTILATION AIR
Ventilation Air From Inside
Building
This fresh air would come from an adjoining
unconfined space. When ventilating to an
adjoining unconfined space, you must pro-
vide two permanent openings: one within
12" of the ceiling and one within 12" of the
floor on the wall connecting the two spaces
(see options 1 and 2, Figure 2). You can also
remove door into adjoining room (see op-
tion 3, Figure 2). Follow the National Fuel
Gas Code, ANSI Z223.1/NFPA 54, Section
5.3, Air for Combustion and Ventilation for
required size of ventilation grills or ducts.
Ventilation Air From Outdoors
Provide extra fresh air by using ventilation
grills or ducts. You must provide two per-
manent openings: one within 12" of the
ceiling and one within 12" of the floor.
Connect these items directly to the outdoors
or spaces open to the outdoors. These spaces
include attics and crawl spaces. Follow the
National Fuel Gas Code, ANSI Z223.1/
NFPA 54, Section 5.3, Air for Combustion
and Ventilation for required size of ventila-
tion grills or ducts.
IMPORTANT:
Do not provide openings for
inlet or outlet air into attic if attic has a
thermostat-controlled power vent. Heated air
entering the attic will activate the power vent.
Or
Remove
Door into
Adjoining
Room,
Option 3
Ventilation Grills
Into Adjoining Room,
Option 2
12"
12"
Ventilation
Grills
into Adjoining
Room,
Option 1