OWNER'S OPERATION AND INSTALLATION MANUAL VENT-FREE PROPANE/LP GAS BAY FRONT FIREPLACE CF26PT

16
107187
VENT-FREE PROPANE/LP BAY FRONT FIREPLACE
CF26PT
For more information, visit www.desatech.com
NOTICE: During initial operation
of new heater, burning logs will
give off a paper-burning smell.
Orange flame will also be present.
Open damper or window to vent
smell. This will only last a few hours.
LIGHTING
INSTRUCTIONS
1. STOP! Read the safety information
on page 15.
2. Make sure equipment shutoff valve
is fully open.
3. Turn control knob clockwise
Clockwise
to the OFF position.
4. Wait five (5) minutes to clear out any
gas. Then smell for gas, including
near the floor. If you smell gas,
STOP! Follow “B” in the safety in-
formation, page 15. If you don’t smell
gas, go to the next step.
5. Turn control knob counterclockwise
C-clockwise
to the PILOT position.
Press in control knob for five (5) sec-
onds (see Figure 28).
Note:
You may be running this
heater for the first time after hook-
ing up to gas supply. If so, the con-
trol knob may need to be pressed in
for 30 seconds or more. This will al-
low air to bleed from the gas system.
If control knob does not pop out when
released, contact a qualified service
person or gas supplier for repairs.
6. With control knob pressed in, press
and release ignitor button. This will
light pilot. The pilot is attached to the
front burner. If needed, keep press-
ing ignitor button until pilot lights.
Note:
If pilot does not stay lit, contact
a qualified service person or gas sup-
plier for repairs. Until repairs are made,
light pilot with match. To light pilot with
match, see Manual Lighting Procedure.
OPERATING
FIREPLACE
Continued
CAUTION: Do not try to adjust
heating levels by using the equip-
ment shutoff valve.
Figure 29 - Pilot
Thermocouple
Ignitor Electrode
Pilot Burner
TO TURN OFF GAS
TO APPLIANCE
Shutting Off Heater
Turn control knob clockwise
Clockwise
to
the OFF position.
Shutting Off Burners Only (pilot
stays lit)
Turn control knob clockwise
Clockwise
to
the PILOT position.
7. Keep control knob pressed in for 30
seconds after lighting pilot. After 30
seconds, release control knob.
Note:
If pilot goes out, repeat steps 3
through 7. This heater has a safety inter-
lock system. Wait one (1) minute for sys-
tem to reset before lighting pilot again.
8. Turn control knob counterclockwise
C-clockwise
to desired heating level. The
burners should light. Set control knob
to any heat level between HI and LO.
Control Knob
Ignitor Button
THERMOSTAT
CONTROL OPERATION
The thermostat control knob can be set to
any comfort level between Hi and Lo. The
thermostat will gradually modulate the
heat output and flame height from higher
to lower settings, or pilot, in order to
maintain the comfort level you select.
The ideal comfort setting will vary by
household depending upon the amount of
space to be heated, the output of the
central heating system, etc.
Note:
Selecting the Hi setting with the
control knob will cause the burner to
remain fully on, without modulating down
in most cases.
MANUAL LIGHTING
PROCEDURE
1. Follow steps 1 through 5 under Light-
ing Instructions, column 1.
2. Depress control knob and light pilot
with match.
3. Keep control knob pressed in for 30
seconds after lighting pilot. After 30
seconds, release control knob. Now
follow step 8 under Lighting Instruc-
tions, column 1.
Figure 28 - Control Knob and Ignitor
Button