OWNER'S OPERATION AND INSTALLATION MANUAL VENT-FREE PROPANE/LP GAS BAY FRONT FIREPLACE CF26PT

13
107187
OWNER’S MANUAL
For more information, visit www.desatech.com
A
U
T
O
O
F
F
ON
INSTALLATION
Continued
Figure 22 - Routing Flexible Gas Line
CONNECTING FIREPLACE
TO GAS SUPPLY
Installation Items Needed
Phillips screwdriver
sealant (resistant to propane/LP gas, not
provided)
1. Route flexible gas line (provided by
installer) from equipment shutoff
valve into fireplace through side or
rear access holes in outer casing (see
Figure 22).
NOTICE: Most building codes do
not permit concealed gas con-
nections. A flexible gas line is
provided to allow accessibility
from the fireplace (see Figure 23).
The flexible gas supply line con-
nection to the equipment shutoff
valve should be accessible.
Equipment
Shut Off
Valve
2. Apply pipe joint sealant lightly to male
threads of gas connector attached to
flexible gas line (see Figure 23).
3. Check all gas connections for leaks. See
Checking Gas Connections, page 14.
4. Feed flexible gas line into fireplace base
area. Make sure the entire flexible gas
line is in fireplace mantel base area.
Figure 23 - Attaching Flexible Gas Lines Together
CAUTION: Avoid damage to
regulator. Hold gas regulator with
wrench when connecting it to gas
piping and/or fittings.
Continued
Outer
Casing
To Gas Supply
Flexible Gas Line from
Fireplace Gas Regulator
To Fireplace Gas
Regulator
Equipment Shutoff Valve
Provided by Installer
To Gas Meter