Instructions / Assembly
www.dero.com | 1-888-337-6729
© 2015 Dero
FIXIT
Maintenance and Replacement
NOTE:
All threads for all parts of the pump are right-hand threads. They tighten clockwise, and loosen counter-
clockwise (“righty tighty, lefty loosey”). However, when you are looking top-town at a bolt that threads
from underneath, if you move it counter-clockwise from your point of view, you are actually tightening, not
loosening, the nut! This has led to some unnecessary breakage of pump parts. Be sure you are looking at the
nut with the proper orientation before tightening or loosening.
1. Remove nut and bolt on
side of Fixit.
2. Remove tamperproof
nut on bottom of Fixit,
using the Tamperproof
Penta Tool supplied for this
purpose.
3. Once Airpump is
removed, but still in
sleeve, remove the 1 3/16”
nut on the bottom of the
sleeve (turning counter-
clockwise). You can now
slide the pump out.
Remove the shrinkwrap.
Unscrew the pumphead
from the brass fitting
(turning counter-
clockwise). You will
need to keep the brass
fitting for the new
pumphead. Replace the
pumphead. If you want
to put on shrinkwrap,
then put the shrinkwrap
sleeve over the hose
before replacing
pumphead. Once
pumphead is on, pull
shrinkwrap sleeve over
the brass fitting and use
a heatgun to shrink it.
Brass
Fitting
REMOVING THE AIR KIT FROM THE FIXIT
CHANGING THE PUMPHEAD
1
2
3
REPLACING TOOLS
There are three bolts at the top of the Fixit. Underneath
are two 3/8” nuts, and one penta tamperproof nut.
These are all best removed with a socket wrench, using
the extension tool to enable you to reach the nuts. Once
the nuts are removed, take o the cap to replace tools.